HomeMy WebLinkAboutCONCRETE TEST 34 - The Grove at Thomson FarmsFile name:
20001SB06232021YK
1E2C2520-79BC-4FF3-BF4B-290B5B4B09F9 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
22.0
Project Name:
The Grove
Test Location:
Northwest coner of building 5 to Northwest coner of
building 6
Client:
Stillwater Equity Partners
Admixtures:
N/A
Ticket Number:
278068
Contractor:
Headwater's Construction
Supplier:
Walters
Mix Number:
192 A
Date:
5/26/2021
Cylinder Log #:
256
Field Test Results:
Set #:
1
Slump
(inches):
5.2
Slump
Maximum
(in):
Entrained Air
(%):
4.90
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
60
Ambient
Temperature
(°F):
45
Unit Weight
(PCF):
142.17
Tested By:
Y. Kabwika
Date:
5/26/2021
Picked Up By:
Leland Steiner
Date:
5/26/2021
Time:
11:00 AM
Max, Min Temperature
Unknown
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/2/2021 4.00 12.56 34930 2781.05 3,000.00 Type 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/23/2021 4.00 12.6 49,705.0 3944.8 3,000.0 Type 2
C 28 6/23/2021 4.00 12.6 49,285.0 3911.5 3,000.0 Type 2
D 28 6/23/2021 4.00 12.6 50,055.0 3972.6 3,000.0 Type 2
Second Break Average:
3942
Date:
06/24/2021
Reviewed By:
E. Vail
Signature: