Loading...
HomeMy WebLinkAboutCONCRETE TEST 33 - The Grove at Thomson FarmsFile name: 20001SB06242021EJB 0269410F-70CE-4581-B2F3-12B0AAD1F002 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 29.5 Project Name: The Grove Test Location: East side of building #7 Client: Stillwater Equity Partners Admixtures: Ticket Number: 278068 Contractor: Headwater's Construction Supplier: Walters Mix Number: 192 Date: 5/27/2021 Cylinder Log #: 263 Field Test Results: Set #: 1 Slump (inches): 5.0 Slump Maximum (in): Entrained Air (%): 6.20 Entrained Air Spec. (%): Concrete Temperature (°F): 62 Ambient Temperature (°F): 61 Unit Weight (PCF): 140.48 Tested By: Y. Kabwika Date: 5/27/2021 Picked Up By: Y. Kabwika Date: 5/27/2021 Time: 10:45 AM Max, Min Temperature 66.2, 49.1 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/3/2021 4.00 12.56 42335 3370.62 3500 Type 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/24/2021 4.00 12.6 58,345.0 4630.6 3,500.0 Type 5 C 28 6/24/2021 4.00 12.6 57,385.0 4554.4 3,500.0 Type 5 D 28 6/24/2021 4.00 12.6 59,435.0 4717.1 3,500.0 Type 4 Second Break Average: 4633 Date: 06/24/2021 Reviewed By: E. Vail Signature: