Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 20-00776 - 2340 Summerfield Ln - New SFRPermit Inspection Summary Permit Status of (Closed) as of Report Date: 06/24/2021 4:19 pm Permit Details Permit Number: 20-00776 2340 Summerfield Ln - New SFR 2340 Summerfield Ln New Single Family Residence Permit Issued Date: 12/01/2020 Permit Inspection Statistics 23Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 82.61% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 12/23/2020PassLarry BeesleyResidential Footing Inspection The forms and rebar are all good. ThanksInspector Comments: 12/30/2020PassLarry BeesleyFoundation Inspection The rebar and the forms are good, you are OK to pour. ThanksInspector Comments: 01/11/2021PassDon AllenRadon-Ground Inspection Get to cover radon systemInspector Comments: 03/10/2021PassLarry BeesleySheeting The sheeting is good. The hold downs need 2 1/2 inch nails ThanksInspector Comments: 03/24/2021FailLarry BeesleyResidential Framing/Structure Inspection Add two studs for girder support and HVAC needs to pass. Then call for a re inspection. Thanks Inspector Comments: 03/29/2021FailLarry BeesleyResidential Insulation Inspection The insulation can not be covered because the framing didn't pass. This house steel needs studs under the girder truss in the front bedroom. Fix and call for a re inspection. Thanks Inspector Comments: 03/30/2021PassLarry BeesleyResidential Framing/Structure Inspection Fix the insulation and call for a re inspection of the insulation. The framing is now good. Thanks Inspector Comments: 03/30/2021PassLarry BeesleyResidential Insulation Inspection The insulation is good to cover. ThanksInspector Comments: 04/06/2021PassCody JonesResidential Sheetrock/Drywall Inspection Sheetrock good to tape.Inspector Comments: 06/16/2021PassLarry BeesleySidewalk Inspection The gravel is good for the sidewalks. ThanksInspector Comments: 06/23/2021FailLarry BeesleyResidential Building Final Fix the smoke detector by the main bathroom and set garage door hinges. Then call for a re inspection. Thanks Inspector Comments: 06/24/2021PassLarry BeesleyResidential Building Final The corrections have been completed, and you are good for the full C.O. ThanksInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 20-00776 2340 Summerfield Ln - New SFR 2340 Summerfield Ln New Single Family Residence Permit Status of (Closed) as of Report Date: 06/24/2021 4:19 pm Permit Inspection Summary Electrical 03/24/2021PassBret StoddardResidential Electrical Service Inspection 03/24/2021PassBret StoddardResidential Electrical Rough-in 06/15/2021PassAlex OwensResidential Electrical Final Inspection Mechanical 03/24/2021FailDon AllenHVAC Rough-in 03/26/2021PassDon AllenHVAC Rough-in 06/15/2021PassDon AllenHVAC Final Inspection Plumbing 01/19/2021PassDon AllenPlumbing Underground Inspection 03/17/2021PassDon AllenPlumbing Rough-in 05/17/2021PassDon AllenPlumbing Water good to cover the water line.Inspector Comments: 05/17/2021PassDon AllenPlumbing Sewer good to cover the sewer lineInspector Comments: 06/15/2021PassDon AllenPlumbing Final Inspection Page 2 of 2