Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS REVISED REDLINED - 20-00776 - 2340 Summerfield Ln - New SFR
Author Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165 Description : 2340 Summerfield Ln - New SFR Address : Record Type : New Single Family Residence Document Filename : SF2B16_-_Athens_A - Stamped Eng Plans.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 20-00776 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1 - Elevation Free text Larry Beesley : Building Open 2 Roof Ventilation as per R806 A1 - Elevation Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A2 - Elevation Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806 A2 - Elevation Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A2 - Elevation Free text Larry Beesley : Building Open 3 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A3 - FTG & FND Free text Larry Beesley : Building Open 4 Radon Reduction System IRC Appendix F A5 - ROOF Free text Larry Beesley : Building Open 6 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) New Single Family Residence Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) 60.00'100.00'60.00'100.00'500 SOUTH STREET BLOCK 16 WATERSEWERLOT: 3LOT: 4 LOT: 2 9.89 24.1710.1124.1940.00 55.0010.00 22.3320.8320.8310.00 12.0012.0010'-0"x10'-0" CONCRETE PAD 18'-0" WIDE CONCRETE DRIVEWAY 6'-0" WIDECONCRETEWALK WAYHOUSE GARAGE TRE E TRE E SIDEWALK PARK STRIP SHEET NUMBER: S1 S1 DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440SITE PLAN 12 7 12 7 5:12 "ATHENS A" MODEL 12 5 INSULATION VALUES & WINDOWS GARAGE ON ALL HOMES SHEET NUMBER: A1 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440ELEVATION Roof Ventilation as per R806 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. 5:12 12 5 "ATHENS A" MODEL SHEET NUMBER: A2 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440ELEVATION Roof Ventilation as per R806 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" S T HD 10STHD10STHD14STHD14STHD14STHD14F-20 F-20F-20 F-20 F-20 F-20 F-20F-20F-20F-20"ATHENS A" MODEL SHEET NUMBER: A3 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440FOOTING &FOUNDATION9/17/2020 Radon Reduction System IRC Appendix F SW-1 SW-1 SW-1SW-1SW-1SW-1 SW-1SW-1SW-1SW-1SW-1SW-1SW-11 23 STANDARD NOTES SQUARE FOOTAGE AREA MAIN LEVEL 1,615 SQ. FT. TOTAL FINISHED UTILITY 34 SQ. FT. 1,615 SQ. FT. GARAGE 470 SQ. FT. "ATHENS A" MODEL SHEET NUMBER: A4 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440MAIN LEVEL9/17/2020 RB-3 RB-4RB-101'-6"7:12RB-2 RB-87:12 RB-1 RB-7 RB-2RB-5RB-14RB-6 5:12 "ATHENS A" MODEL SHEET NUMBER: A5 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440ROOFFRAMING9/17/2020 Roof Trusses (designed according to R802. 10.1) 35 # Snow and 90 mph winds (Local Conditions) LOW VOLTAGELOCATIONABOVE SHELFNOTE: ADD OUTLET IN ATTIC NEXT RADON PIPE FOR RADON SYSTEM "ATHENS A" MODEL SHEET NUMBER: A6 A61/4" = 1'-0" SCALE (FULL SIZE 24" x 36" PAPER) 1/8" = 1'-0" SCALE (HALF SIZE 11" x 17" PAPER) DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440ELECTRICALLAYOUT INSULATION VALUES & WINDOWS GARAGE ON ALL HOMES SHEET NUMBER: D3 DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440DETAILSD1 SEE ENGINEERING NOTES AND DETAILS IF ADDITIONAL ITEMS ARE NEED FOR OPENINGS SHEET NUMBER: D3 DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440DETAILSD2 GLASS BETWEEN SHOWER & TUB T I L ECEILING REFRIG.DISHBD24 DISH SINK DRAWERS "A" REF.RANGE MICRO. "B"MIN. 39" OPENING 36" UPPER 36" UPPER "C" DRAWERS RANGESINKW27W27BC36 WC24W36 1 1/2" FILLER 1 1/2" FILLER B27B15W30W39END PANEL END PANEL D24B36B18STD. OVERHANGC B A SHEET NUMBER: D3 D3 DRAWN BY: REVISIONS: 3. 1. 2. DATE: ADDRESS:SHEET NAME:JOB: SF2B16 WWW.KARTCHNERHOMES.COM© 2012 Kartchner Homes, Inc. All floor plansand elevations are conceptual only and shouldnot be viewed as a actual representation ofcompleted house. The use of these plans,elevations and rendering limited to KartchnerHomes, Inc. Re-use, reproduction, or publicationby any method, in whole or in part, is strictlyprohibited. Subject to change without notice.KARTCHNER HOMES1075 S. UTAH AVE STE 100IDAHO FALLS, ID 83402(208) 529-2116ATHENS ASUMMERFIELD SUBD.BLOCK: 16, LOT: 2REXBURG, ID 83440DETAILS STRUCTURALDETAILSSHEET NUMBER: SD1 SD2SHEET NAME:9/17/2020 STRUCTURALDETAILSSHEET NUMBER: SD2 SD2SHEET NAME:9/17/2020