Loading...
HomeMy WebLinkAboutCOMCHECK - 04-00202 - Hollywood Video-Game Crazy - RemodelPermit Number Lighting Compliance Certificate Checked By/Date 2000 IECC COMcheck-EZ Software Version 2.4 Release 2b Data filename: C:)Documents and SettingsULH\Desktop\Rexburg.cck Section 1: Project Information Project Name: Hollywood Video #012104 148 W. MAIN ST. Rexburg, ID Designer/Contractor: Ken McCracken, RHL Design Group, Inc. Document Author: Ken McCracken, RHL Design Group, Inc. Notes: Envelope and mechanical are unchanged by this work. Section 2: General Information Building Use Description by: Activity Type Activity Type(s) Floor Area Retail Sales, Wholesale Showroom 7245 Project Description (check one): New Construction _ Addition/4 Alteration _ Unconditioned Shell (File Affidavit) Section 3: Requirements Checklist Bldg. Dept. Use [ ] Interior Lighting 1. Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 15215 11338 YES Exterior Lighting 2. Efficacy greater than 45 lumens/W Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring [ ] 3. Independent controls for each space (switch/occupancy sensor). Exception: Areas that must be continuously lighted. [ ] 4. Master switch at entry to hotel/motel guest room. [ ] 5. Two switches or dimmer in each space to provide uniform light reduction capability. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storage, restroom, or lobby; Areas that must be continuously lighted; [ ] 6. Photocell/astronomical time switch on exterior lights. Exceptions: Areas requiring lighting during daylight hours [ ] 7. Tandem wired one -lamp and three -lamp ballasted luminaires. Exceptions: Electronic high -frequency ballasts; Luminaires not on same switch Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2000 IECC requirements in COMcheck-EZ Version 2.4 Release 2b and to comply with the mandatory requirements in the Requirements Checklist. I , vl L 4U,O- Ott S�2B v� Principal Lighting Designer -Name S' lure Date Lighting Application Worksheet 2000 IECC COMcheck-EZ Software Version 2.4 Release 2b Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Area Category (ft2) (watts/ft2) (B x Q Retail Sales, Wholesale Showroom 7245 2.1 15215 Section 2: Actual Lighting Power Calculation A B Fixture Fixture Description / ID Lamp Description / Wattage Per Lamp / Ballast d Strip Fluorescent / 48" T8 32W / Electronic i 2x4 Recessed (Existing) / 48" T8 32W / Electronic k lx4Recessed (Existing) / 48" T8 32W / Electronic Total Allowed Watts = 15215 C D E F Lamps/ # of Fixture Fixture Fixtures Watt. D x E 2 6 62 372 3 103 86 8858 2 34 62 2108 Total Actual Watts = 11338 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 15215 Total Actual Watts = 11338 Project Compliance = 3877 Lighting PASSES: Design 25% better than code