HomeMy WebLinkAboutTRUSSES - 04-00199 - 107 Star View Dr - New SFRJob Name: PHO-BARZEE Truss ID: Al Qty: 2 Drwg: I
BRG
X-LOC
REACT SIZE REQ1D
TC 2x4 DFL #1 & Btr.
Plating spec : ANSI/TPI - 1995
1
0- 2-12
1400 5.500
5.50"
BC 2x4 DFL #1 & Btr.
THIS DESIGN IS THE COMPOSITE RESULT OF
2
27- 9- 4
1400 5.50•
5.50•
WEB 2x4 DFL STUD
MULTIPLE LOAD CASES.
BRG REQUIREMENTS shown are based ONLY
GBL BLK 2x4 DFL STUD
IRC/IBC truss plate values are based on
an the truss material at each bearing
Loaded for 10 PSF non -concurrent BOLL.
testing and approval as required by IBC 1703
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
and ANSI/TPI and are reported in available
TC
FORCE
AXL
BND
CSI
Pg = 35 psf, Ce = 1.0, I = 1.0, Ct = 1.00
documents such as ICBO #1607.
1-2
-2312
0.13
0.76
0.89
This truss is designed using the
Gable verticals are 2x 4 web material spaced
2-3
-1560
0.01
0.75
0.77
ASCE7-98 wind Specification
at 24.0 " o.c. unless noted otherwise.
3-4
-1560
0.01
0.73
0.77
Bldg Enclosed = Yes, Importance Factor = 1.00
Top chord supports 24.0 " of uniform load
4-5
-2312
0.13
0.76
0.89
Truss Location = Not End Zone
at 35 psf live load and 8 psf dead load.
Hurricane/Ocean Line = No , Exp Category = C
Additional design considerations may be
BC
FORCE
AXL
BND
CSI
Bldg Length = 99.00 ft, Bldg Width = 50.00 ft
required if sheathing is attached.
6-7
1905
0.27
0.54
0.81
Mean roof height = 24.09 ft, mph = 90
[+] indicates the requirement for lateral
7-8
1902
0.27
0.2S
o.52
TPI Standard Occupancy, Dead Load 14.5 psf
bracing (designed by others) perpendicular
8-9
1902
0.27
0.25
0.52
Designed as Main Wind Force Resisting System
to the plane of the member at 48"intervals.
9-10
1905
0.27
0.54
0.81
and Components and Cladding
Bracing is a result of wind load applied
Gx.L
0.00
0.04
0.04
Tributary Area = 56 sqft
to member.(Combination axial plus bending).
GH.R
0.00
0.04
0.04
This truss requires adequate sheathing, as
designed by others, applied to the truss
WEB
FORCE
CS1
WEB
FORCE CSI
face providing lateral support for webs in
2-7
234 0.07
4-8
-848 0.88
the truss plane and creating shear wall
2-8
-848 0.88
4-9
234 0.07
action to resist diaphragm loads.
3-8
942 0.32
7-6-4 6-56-5 6-5-12 1 7-6_4
7-6-4 14-" 20-5-12 28-"
14-" 14-0-0
1 2 3 4 5
700
8-2-4
3-
0-0-4
3.5
.7.00 ,
UPLIFT REACTIONS) :
Support C&C Wind Non -Wind
1 -93 lb
2 -93 lb
HORIZONTAL REACTIONS)
support 1 -256 lb
support 2 256 lb
8-2-4
SHIP
0-0-4
.==== Joint Locations =====
1 0- 0- 0 6 0- 0- 0
2 7- 6- 4 7 7- 6- 4
3 14- 0- 0 8 14- 0- 0
4 20- 5-12 9 20- 5-12
5 28- 0- 0 10 28- 0- 0
28-"
6 7 8 9 10
77-6_4� 6-5.12 -1 6.5-12� 7.6_4
TYPICAL PLATE: 2-3
7-6-4 14-" 20-5-12 28-"
11 / 312004
All plates are 20 gauge Truswal Connectors unless preceded by "MV for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 5/32" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARRZEE
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFaes L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 pSf
Rep Mbr Bnd 1.15
noted. Bracing shown is for lateral support ofcomponents members only to reduce buckling length. This component shall not be placed in any
SYSTEMS
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.spaeing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.50
Design Spec IRC
'ANSI/TPI 1', 'WTCA 1' - Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
psf
1101 4. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and'HIB-91 SUMMARY SHEET by TPI. The Truss Plate Institute (TPI) is located at D'Onofiio Drive,
TOTAL 50.00
Seqn T6.4.12 - 0
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
psf
2991
IJob Name: PHO-BARZEE
Truss ID: A2
21 D
BRG
X-LOC
REACT SIZE REQ'D
TC 2x4 DFL #1 & Btr.
1
0- 2-12
1660 5.50" 1.77"
BC 2x4 DFL #1 & Btr.
2 27-
9- 4
1660 5.500 1.771
WEB 2x4 DFL STUD
BRG REQUIRmIENT8 shown are based ONLY
Loaded for 10 PSF non -concurrent BOLL.
on the
truss material at each bearing
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg - 35 psf, Ce - 1.0, I - 1.0, Ct - 1.00
TC
FORCE
AYL 13ND CSI
This truss is designed using the
1-2
-2198
0.02 0.69 0.72
ASCE7-98 Wind Specification
2-3
-1529
0.01 0.69 0.71
Bldg Enclosed = Yes, Importance Factor - 1.00
3-4
-1529
0.01 0.69 0.71
Truss Location - Not End Zone
4-5
-2198
0.02 0.69 0.72
Hurricane/Ocean Line - No , Exp Category - C
Bldg Length - 99.00 ft, Bldg Width - 50.00 ft
BC
FORCE
AXL BND CSI
Mean roof height - 24.26 ft, mph o 90
6-7
1777
0.25 0.10 0.35
TPI Standard Occupancy, Dead Load - 14.5 psf
7-8
1775
0.25 0.10 0.35
Designed as Main Wind Force Resisting System
8-9
1775
0.25 0.10 0.35
and Components and Cladding
9-10
1777
0.25 0.10 0.35
Tributary Area - 56 sqft
WEB FORCE CSI WEB FORCE CSI
2-7 208 0.06 4-8 -756 0.85
2-8 -756 0.85 4-9 207 0.06
3-8 856 0.29
8-6-5
=0-4-5
Plating spec : ANSI/TPI - 1995 UPLIFT REACTIONS) :
THIS DESIGN IS THE COMPOSITE RESULT OF Support C&C Wind Non -Wind
MULTIPLE LOAD CASES. 1 -166 lb
IRC/IBC truss plate values are based on 2 -166 lb
testing and approval as required by IBC 1703 HORIZONTAL REACTIONS) :
and ANSI/TPI and are reported in available support 1 -265 lb
documents such as ICBO #1607. support 2 -265 lb
7-2-1 3 6-9-3 1 6-9-3 7-2-1 3
7-2-13 14-" 20-9-3 28-"
14-" 14-"
1 2 3 4 5
700
3-5
-0-0
28-0-0
•7.00�
6 7 8 9 10
7.2� 6.9� 6-9-3 ,� 7-2-13
7-2.13 14-" 20-9-3 28-0-0
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HIS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
MAX DEFLECTION (span) .
L/999 IN MEN 7-8 (LIVE)
L- -0.100 D- -0.04" To -
a --a- Joint Locations - --- =
1 0- 0- 0 6 0- 0- 0
2 7- 2-13 7 7- 2-13
3 14- 0- 0 8 14- 0- 0
4 20- 9- 3 9 20- 9- 3
5 28- 0- 0 10 28- 0- 0
11 / 3/2004
Scale: 5132" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BAIT-BARZEE
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsg nr' DGM
'
`
ato be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
re
TC Live 35.00 psf
7.50
DurFacs L=1.15 P=1.15
Rep M br Bnd 1.15
TRUSWAL
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
TC Dead psf
SYSTEMS
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this thus in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software,
'ANSI/TPI 1','WTCA 1' - Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
BC Dead 7.50 psf
Design Spec IRC
1101 N. Groat S.W. Pkwy.. Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
is located 1111 19th Street, NW, Ste 800, Washington, DC 20036,
TOTAL 50.00 psf
Segn T6.4.12 - 0
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) at
L4"
Job Name: PHO-BARZEE
Truss ID: A3
TC 2x4 DFL #1 & Btr.
BC 2x4 DFL #1 & Btr.
GBL BLK 2x4 DFL STUD
Loaded for 10 PSF non -concurrent BCLL.
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg a 35 psf, Ce a 1.0, I a 1.0, Ct = 1.00
Gable verticals are 2x 4 web material spaced
at 24.0 " o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 35 psf live load and 8 psf dead load.
Additional design considerations may be
required if sheathing is attached.
[+1 indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 48"intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
documents such as ICBO #1607.
8.6-0 8-6-0
1 2 3 4 5 6 7 8 9
700
2.5
5-6
•7.00
1
Drwg:
UPLIFT REACTIONS)
Support C&C Wind Non -Wind
1 -13 lb
2 -13 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed " Yes, Importance Factor a 1.00
Truss Location Not End Zone
Hurricane/Ocean Line a No , Exp Category a C
Bldg Length = 99.00 ft, Bldg Width a 50.00 ft
Mean roof height a 22.49 ft, mph = 90
TPI Standard Occupancy, Dead Load = 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area - 34 sqft
4-11-12
SHIP
0-0-4
=a=== Joint Locations =====
1 0- 0- 0 10 0- 0- 0
2 2- 6- 0 11 2- 6- 0
3 4- 6- 0 12 4- 6- 0
4 6- 6- 0 13 6- 6- 0
5 8- 6- 0 14 8- 6- 0
6 10- 6- 0 15 10- 6- 0
7 12- 6- 0 16 12- 6- 0
8 14- 6- 0 17 14- 6- 0
9 17- 0- 0 18 17- 0- 0
17-0-0
10 11 12 13 14 15 16 17 18
TYPICAL PLATE: 2-3 11 / 312004
OVER CONTINUOUS SUPPORT
All plates are 20 gauge Truswal Connectors unless preceded by "W" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 9132" = V
TRUSWAL
SYSTEMS
1101 N. Great S.W. Pkwy.. Arlington TX 76011
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
utilized on this designmeet imposed or exceed the loading imped by the local building code and the particular application. The dcsign assumes that the top chord
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
'ANSIlrPi 1'.'WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
Eng. Job:.EJ.
Chk: BJS
Dsgnr' DGM
'
WO: BATT-BARZEE
TC Live 35.00 psf
TC Dead 7.50 psf
BC Live 0.00 psf
BC Dead 7.50 psf
TOTAL 50.00 psf
DurFaes L-1.15 P-1.15
Rep Mbr Bnd 1.15
O.C.Spacing 2. 0- 0
Design Spec [RC
Seqn T6.4.12 - 0
Wob Name: PHO-BARZEE Truss ID: B1 Qty: 1 Drwg: I
BRG
X-LOC
REACT SIZE REQ'D
TC 2x4 DFL #1 & Btr.
1
0- 2-12
1300 5.50" 5.50"
BC 2x4 DFL #1 & Btr.
2 25-
9- 4
1300 5.50" 5.50"
WEB 2x4 DFL STUD
BRG REQUIREMENTS shown are based ONLY
GBL BLK 2x4 DFL STUD
on the
truss material at each bearing
Loaded for 10 PSF non -concurrent BCLL.
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
TC
FORCE
AXL
BND
CSI
Pg - 35 psf, Ce a 1.0, I = 1.0, Ct - 1.00
1-2
-2145
0.10
0.62
0.72
This truss is designed using the
2-3
-1447
0.01
0.65
0.66
ASCE7-98 Wind Specification
3-4
-1447
0.01
0.65
0.66
Bldg Enclosed " Yes, Importance Factor a 1.00
4-5
-2145
0.10
0.62
0.72
Truss Location a Not End Zone
Hurricane/Ocean Line a No , Exp Category a C
BC
FORCE
AXL
BND
CSI
Bldg Length = 99.00 ft, Bldg Width a 50.00 ft
6-7
1768
0.25
0.49
0.74
Mean roof height a 23.80 Et, mph 90
7-8
1765
0.25
0.22
0.47
TPI Standard Occupancy, Dead Load = 14.5 psf
8-9
1765
0.25
0.22
0.47
Designed as Main Wind Force Resisting System
9-10
1768
0.25
0.49
0.74
and Components and Cladding
GH.L
0.00
0.04
0.04
Tributary Area a 52 sgft
GH.R
0.00
0.04
0.04
WEB FORCE CSI WEB FORCE CSI
2-7 211 0.07 4-8 -788 0.70
2-8 -788 0.70 4-9 211 0.07
3-8 880 0.29
7-7-4
0-0-4
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
documents such as ICBO #1607.
Gable verticals are 2x 4 web material spaced
at 24.0 " o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 35 psf live load and 8 psf dead load.
Additional design considerations may be
required if sheathing is attached.
1+) indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 48"intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
77-0-4 5-1_ 112 5-1� 7-0�
7-0-4 13-0-0 18-11-12 26-0-0
13-M 13-0-0
1 2 3 4 5
700 -7.00
UPLIFT REACTION(S) :
Support C&C Wind Non -Wind
1 -88 lb
2 -88 lb
HORIZONTAL REACTIONS)
support 1 -236 lb
support 2 236 lb
7-7-4
SHIP
0-0-4
a=a=a Joint Locations =a =
1 0- 0- 0 6 0- 0- 0
2 7- 0- 4 7 7- 0- 4
3 13- 0- 0 8 13- 0- 0
4 18-11-12 9 18-11-12
5 26- 0- 0 10 26- 0- 0
26-0-0
6 7 8 9 10
TYPICAL PLATE: 2-3 77-0-4 5-11-12 1 5-1� 77-0-4 11 / 312004
7-0-4 13-0-0 18-11-12 26-0-0
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 3116" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFacs L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50
Rep Mbr Bnd 1.15
noted, Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
psf
SYSTEMS
environmrnt that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0. 0
1
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software,
BC Dead 7.50
Design Spec IRC
ANSI/TPI 1'.'WTCA 1' - Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
psf
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofiio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 50.00 psf
Seqn T6.4.12 - 0
24"
lJob Name: PHO-BARZEE Truss ID: B2 Qtv: 7 Drwq: I
BRG
X-LOC
REACT SIZE RHQ'D
TC 2x4 DFL #1 & Btr.
1
0- 2-12
1560 5.50"
1.66"
BC 2x4 DFL #1 & Btr.
2 25- 9- 4
1300 5.50"
1.50"
WEB 2x4 DFL STUD
BRG REQvIRECRUS shown are based ONLY
Loaded for 10 PSF non -concurrent BOLL.
on the truss material at
each bearing
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg a 35 psf, Ce a 1.0, I a 1.0, Ct a 1.00
TC
FORCE
AYL WM
CSI
This truss is designed using the
1-2
-2042
0.02 0.59
0.61
ASCE7-98 Wind Specification
2-3
-1423
0.01 0.59
0.60
Bldg Enclosed a Yes, Importance Factor a 1.00
3-4
-1423
0.01 0.59
0.60
Truss Location a Not End Zone
4-5
-2042
0.02 0.59
0.61
Hurricane/Ocean Line a No , Exp Category a C
Bldg Length a 99.00 ft, Bldg Width a 50.00 ft
BC
FORCE
AYL BND
CSI
Mean roof height - 23.97 ft, mph a 90
6-7
1656
0.24 0.06
0.30
TPI Standard Occupancy, Dead Load 14.5 psf
7-e
1654
0.24 0.10
0.34
Designed as Main Wind Force Resisting System
8-9
1654
0.24 0.10
0.34
and Components and Cladding
9-10
1656
0.24 0.06
0.30
Tributary Area a 52 sgft
WEB FORCE CSI WEB FORCE CSI
2-7 181 0.06 4-8 -699 0.70
2-8 -699 0.70 4-9 181 0.06
3-8 767 0.26
Plating spec : ANSI/TPI - 1995 UPLIFT REACTIONS) :
THIS DESIGN IS THE COMPOSITE RESULT OF Support C&C Wind Non -Wind
MULTIPLE LOAD CASES. 1 -161 lb
IRC/IBC truss plate values are based on 2 -82 lb
testing and approval as required by IBC 1703 HORIZONTAL REACTIONS)
and ANSI/TPI and are reported in available support 1 -245 lb
documents such as ICBO #1607. support 2 245 lb
12"
6-5-14 6-fi2 6-66-6 2 6-5-14
6-5-14 13-M 19-6-2 26-0-0
13-M 13-0-0
1 2 3 4 5
7.00
3-5
-0�
2fi-0-0
-7�
7 8 9 10
6-5-14 6-0-2 6-6-2 6-5-14
6-5-14 13-0-0 19-6-2 26-0-0
9-1-1
SHIP
t-4
=0.4-5
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
aaaaa Joint Locations ac===
1 0- 0- 0 6 0- 0- 0
2 6- 5-14 7 6- 5-14
3 13- 0- 0 8 13- 0- 0
4 19- 6- 2 9 19- 6- 2
5 26- 0- 0 10 26- 0- 0
11 / 3/2004
Scale: 5132" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr: DGM
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFaes L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 psf
Rep Mbr Bnd 1.15
SYSTEMS
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software,
Design Spec IRC
'ANSVfPI 1% VTCA 1' - Wood Truss Council of America Standard Design Responsibilities, WANDLING INSTALLING AND BRACING METAL
BC Dead 7.50 psf
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (RIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onoftio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 50.00 psf
Seqn T6.4.12 - 0
Job Name: PHO-BARZEE Truss ID: B3 Qty: 5 Drwg: I
DR!
X-LOC
REACT SIZE REQID
TC 2x4 DFL #1 & Btr.
0- 2-12
1560 5.50" 1.66"
BC 2x4 DFL #1 & Btr.
2 25- 9- 4
1560 S.50" 1.66"
WEB 2x4 DFL STUD
BRG REQUIRWOMS shown are based ONLY
Loaded for 10 PSF non -concurrent BOLL.
on the truss material at each bearing
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg a 35 psf, Ce = 1.0, I a 1.0, Ct - 1.00
TC
FORCE
AYL BND
CSI
This truss is designed using the
1-2
-2042
0.02 0.59
0.61
ASCE7-98 Wind Specification
2-3
-1423
0.01 0.59
0.60
Bldg Enclosed a Yes, Importance Factor a 1.00
3-4
-1423
0.01 0.59
0.60
Truss Location a Not End Zone
4-5
-2042
0.02 0.59
0.61
Hurricane/Ocean Line a No , Exp Category a C
Bldg Length = 99.00 ft, Bldg Width = 50.00 ft
BC
FORCE
AXL BND
CS
Mean roof height a 23.97 ft, mph a 90
6-7
1656
0.24 0.06
0.30
TPI Standard Occupancy, Dead Load a 14.5 psf
7-8
16S4
0.24 0.10
0.34
Designed as Main Wind Force Resisting System
8-9
1654
0.24 0.10
0.34
and Components and Cladding
9-10
1656
0.24 0.06
0.30
Tributary Area = 52 sqft
WEB FORCE CSI WEB FORCE CSI
2-7 181 0.06 4-8 -699 0.70
2-8 -699 0.70 4-9 181 0.06
3-8 767 0.26
Plating spec : ANSI/TPI - 1995 UPLIFT REACTIONS) :
THIS DESIGN IS THE COMPOSITE RESULT OF Support C&C Wind Non -Wind
MULTIPLE LOAD CASES. 1 -161 lb
IRC/IBC truss plate values are based on 2 -161 lb
testing and approval as required by IBC 1703 HORIZONTAL REACTIONS)
and ANSI/TPI and are reported in available support 1 245 lb
documents such as ICBO #11607. support 2 -245 lb
6-5-14� 6-6� 6-6-2 6-5_ 141
6-5-14 13-M 19.6-2 26-0-0
13-M 13-M
1 2 3 4 5
7.0 -
3-5
-7�
i2-0-0 i 2F -0-00
26-0-0
7 8 9 10
6-56-514 6-6.2 1 6-6-2 6-514
6-5-14 13-M 19-0-2 26-"
9-1-1
SHIP
MO-4.5
All plates are 20 gauge Truswal Connectors unless preceded by "NIX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
MAX DEFLECTION (span) :
L/999 IN MEN 7-8 (LIVE)
L= -0.09" Da -0.04" Ta -
==a== Joint Locations as==a
1 0- 0- 0 6 0- 0- 0
2 6- 5-14 7 6- 5-14
3 13- 0- 0 8 13- 0- 0
4 19- 6- 2 9 19- 6- 2
5 26- 0- 0 10 26- 0- 0
11/ 3/2004
Scale: 5132" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
manufacturer to be verified by the component manufactuand/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFaes L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached unless otherwise
TC Dead 7.50
Rep M br Bnd 1.15
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
psf
SYSTEMS
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.50
Design Spec IRC
'ANSIITPI 1','WTCA 1' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
psf
1101 N. Great S.W. Pkwy., AdIngton TX 76011
PLATE CONNECTED WOOD TRUSSES'- (H1B-91) and'HIB-91 SUMMARY SHEET by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 50.00 psf
Seqn T6.4.12 - 0
12"
lJob Name: PHO-BARZEE Truss ID: B4 Qty: 4 Drwg: I
BRG X-LOC REACT SIZE REQ'D TC 2x4 DFL #1 & Btr.
1 2- 2-12 1611 5.500 1.50• BC 2x4 DFL #1 & Btr.
2 25- 9- 4 1452 5.50• 1.55" WEB 2x4 DFL STUD
BRG REQUIRMIENTS shorn are based ONLY IRC/IBC truss plate values are based on
on the truss material at each bearing testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
TC FORCE AXL BND CSI documents such as ICBO #1607.
OL- 1 92 0.01 0.32 0.34 Left Overhang(s) are not to be removed.
1-2 880 0.12 0.61 0.74 OVERHANG(S) MAY BE SHORTENED UP TO 3" MAX.1
2-3 -1226 0.01 0.61 0.62 Left Overhang Soffit loading a 0.0 psf
3-4 -1226 0.01 0.60 0.60
4-5 -1851 0.02 0.60 0.61
BC FORCE AXL BND CSI
6-7 -631 0.00 0.21 0.21
7-8 1146 0.14 0.21 0.35
8-9 1147 0.07 0.22 0.29
9-10 1490 0.21 0.11 0.32
10-11 1492 0.21 0.07 0.28
WEB FORCE CSI WEB FORCE CSI
2-7 -2125 1.00 3-9 571 0.19
2-8 168 0.05 4-9 -705 0.71
2-9 -248 0.24 4-10 184 0.06
®Web bracing required at each location shown.
See standard details (TX01087001-001).
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
Loaded for 10 PSF non -concurrent BCLL.
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg a 35 psf, Ce = 1.0, I a 1.0, Ct - 1.00
6-7-10 6-4-6 6.6 2 6-5J�
6-7-10 13-0-0 19-6-2 26-M
13-" 13-"
1 2 3 4 5
F7.00
3-5
-7�
A'0-1 21- -"
26-0-a
UPLIFT REACTIONS) :
Support C&C Wind Non -Wind
1 -225 lb
2 -152 lb
HORIZONTAL REACTION(S)
support 1 -280 lb
support 2 -280 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed = Yes, Importance Factor = 1.00
Truss Location a Not End Zone
Hurricane/Ocean Line a No , Exp Category - C
Bldg Length - 99.00 ft, Bldg Width = 50.00 ft
Mean roof height = 23.97 ft, mph a 90
TPI Standard Occupancy, Dead Load = 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area - 52 sgft
9-1-1
SHIP
=0-4-5
MAX DEFLECTION (span) :
L/999 IN MEN 8-9 (LIVE)
La -0.07" D= -0.03" T= -
MAX DEFLECTION (cant) :
L/986 IN MEM 6-7 (LIVE)
La -0.03" Da -0.01" T=
===== Joint Locations =====
1 0- 0- 0 7 2- 2-12
2 6- 7-10 8 6- 7-10
3 13- 0- 0 9 13- 0- 0
4 19- 6- 2 10 19- 6- 2
5 26- 0- 0 11 26- 0- 0
6 0- 0- 0
6 7 8 9 10 11
2-2-12 _j 4� 6-6 6.6-2 6-5-14 -I 11 / 3/2004
2-2-12 6-7-10 13-0-0 19-6.2 26-0-0
All plates are 20 gauge Truswal Connectors unless preceded by "W" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 5132" = V
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr'' DGM
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DUrFaCS L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 psf
Rep Mbr Bnd 1.15
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
SYSTEMS
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.50
Design Spec IRC
'ANSUTPI 1','WTCA I'- Wood Thus Council of America Standard Design Rcsponssbilities,'HANDLING INSTALLING AND BRACING METAL
psf
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and'HIB-91 SUMMARY SHEET by TPI. The Truss Plate Institute (TPI) is located at D'Onofiio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800. Washington, DC 20036.
TOTAL 50.00 psf
Seqn T6.4.12 - 0
LO"
)4"
Job Name: PHO-BARZEE Truss ID: C1 Qty: 1 Drwg: I
TC 2x4 DFL #1 & Btr.
BC 2x4 DFL #1 & Btr.
GBL BLK 2x4 DFL STUD
Loaded for 10 PSF non -concurrent BOLL.
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg = 35 psf, Ce = 1.0, I = 1.0, Ct = 1.00
Gable verticals are 2x 4 web material spaced
at 24.0 " o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 35 psf live load and 8 psf dead load.
Additional design considerations may be
required if sheathing is attached.
[+] indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 48"intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
4.4-5
0-0-4
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
documents such as ICBO #1607.
r 7-5-4 1 7-5.4
1 2 3 4 5 6 7
700
-7.00�
s.s
14-10-8
10 11 12 13 14
UPLIFT REACTIONS) :
Support C&C Wind Non -Wind
1 -57 lb
2 -20 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed Yes, Importance Factor = 1.00
Truss Location = Not End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length o 99.00 ft, Bldg Width = 50.00 ft
Mean roof height = 22.18 ft, mph = 90
TPI Standard Occupancy, Dead Load = 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area = 30 sqft
4.4-5
HIP
0-0-4
TYPICAL PLATE: 2-3
OVER CONTINUOUS SUPPORT
All plates are 20 gauge Truswal Connectors unless preceded by "W" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
= == Joint Locations
1 0- 0- 0 8 0- 0- 0
2 3- 5- 4 9 3- 5- 4
3 5- 5- 4 10 S- 5- 4
4 7- 5- 4 11 7- 5- 4
5 9- 5- 4 12 9- 5- 4
6 11- 5- 4 13 11- 5- 4
7 14-10- 8 14 14-10- 8
11 / 3/2004
Scale: 11132" =19
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
are to be verified by the component manufacturer and/or budding designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFacs L=1.15 P=1.15
utilized on this design mat or exceed the loading unposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally, braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 psf
p
Re M br Bnd 1.15
p
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
SYSTEMS
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spaeing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 750
ea
Design Spec IRC
g p
'ANSVrPI 1','WTCA 1' - Wood Thus Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
.p
psf
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onoirio Drive,
50.00
Seqn T6.4.12 - 0
Madison. Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1 111 19th Street, NW, Ste 900, Washington, DC 20036.
TOTAL psf
Job Name: PHO-BARZEE Truss ID: C2 Qty: 9 Drwg: I
BRG X-LOC REACT SIZE REQ4D TC 2x4 DFL #1 & Btr.
1 0- 2-12 1004 5.50" 1.50" BC 2x4 DFL #1 & Btr.
2 14- 7-12 1004 5.50" 1.50" WEB 2x4 DFL STUD
ERG REQuiREMErrrs shown are based ONLY Loaded for 10 PSF non -concurrent BCLL.
an the truss material at each bearing ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg - 35 psf, Ce - 1.0, I = 1.0, Ct - 1.00
TC FORCE AXL END CSI This truss is designed using the
1-2 -953 0.01 0.63 0.64 ASCE7-98 Wind Specification
2-3 -953 0.01 0.63 0.64 Bldg Enclosed = Yes, Importance Factor - 1.00
Truss Location Not End Zone
BC FORCE AXL END CSI Hurricane/Ocean Line = No , Exp Category - C
4-5 699 0.07 0.33 0.39 Bldg Length - 99.00 £t, Bldg Width - 50.00 ft
5-6 699 0.07 0.33 0.39 Mean roof height = 22.35 ft, mph - 90
TPI Standard Occupancy, Dead Load - 14.5 psf
WEB FORCE CSI WEB FORCE CSI Designed as Main Wind Force Resisting System
2-5 222 0.07 and Components and Cladding
Tributary Area = 30 sgft
4-8-6
I0 4-5
Plating spec : ANSI/TPI - 1995 UPLIFT REACTIONS) :
THIS DESIGN IS THE COMPOSITE RESULT OF Support C&C Wind Non -Wind
MULTIPLE LOAD CASES. 1 -142 lb
IRC/IBC truss plate values are based on 2 -142 lb
testing and approval as required by IBC 1703 HORIZONTAL REACTIONS)
and ANSI/TPI and are reported in available support 1 -136 lb
documents such as ICBO #1607. support 2 -136 lb
7-5-4
7-5-4
7-5_4
14-10-8
i 7_5-4 1 7-5-4
1
1 2 3
700
s.s
_7.00
5-10-2
SHIP
=0-4-5
MAX DEFLECTION (span) :
L/999 IN MEM 4-5 (LIVE)
L- -0.10" D.
-0.04" T= -
==_=. Joint Locations =====
1 0- 0- 0 4 0- 0- 0
2 7- 5- 4 5 7- S- 4
3 14-10- 8 6 14-10- 8
2-0-0 2� 0-0
~-i
14-10.8
4 7-5�5 7-5-4
11 / 3/2004
7_5.4 14-10-8
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 1t4" =1'
WARMNG Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: GATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component rnanuficturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr: DGM
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
7.50
DurFacs 1-=1.15 P=1.15
Rep Mbr Bnd 1.15
TRUSWAL
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
islaterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
TC Dead psf
SYSTEMS
environment that will cause the moisture content of the wood to exceed 190/6 and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this thus in accordance with the foilowing standards: 'Joint and Cutting Detail Reports available as output from Truswal software,
'ANSI/TPI 1','WTCA I'- Wood Truss Council of America Standard Design Responsibilities, HANDLING INSTALLING AND BRACING METAL
BC Dead 7.50 psf
Design Spec IRC
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste $00, Washington, DC 20036.
TOTAL 50.00 psf
Segn T6.4.12 - 0
4"
IJob Name: PHO-BARZEE
Truss ID: C3
BRG
X-LOC
REACT SIZE REQ'D TC 2x4 DFL #1 & Btr.
1
0- 2-12
5412 5.50"
2.890 BC 2x6 DFL SS
2 14-
7-12
5412 5.50•
2.89" WEB 2x4 DFL STUD
BRG REQuiR8lums shwa, are
based ONLY Loaded for 10 PSF non -concurrent BCLL.
on the
truss material at
each
bearing ASCE7-98 SNOW LOAD DESIGN CRITERIA:
Pg a 35 psf, Ce = 1.0, I = 1.0, Ct = 1.00
TC
1-2
FORCE
-7168
AXL BND
0.17 0.17
CSI
0.34
+ + + + + + + + + + + + + + + + + + + 4 + +
Nail pattern shown is for PLF loads only.
2-3
-5079
0.06 0.09
0.15
Concentrated loads MUST be distributed to
3-4
-5079
0.06 0.09
0.15
each ply equally. On multi -ply with hangers,
4-5
-7168
0.17 0.17
0.34
use 3" nails min. into the carrying member.
For more than 2 ply, use additional fasten -
BC
FORCE
AYL BND
CSI
ers as indicated from the back plys, or use
6-7
6132
0.25 0.26
0.51
any other approved detail (by others).
7-8
6072
0.25 0.21
0.46
+ + + + + + + + + + + + + t + 4 + + + + + +
8-9
6072
0.2S 0.21
0.46
9-10
6132
0.25 0.26
0.51
WEB FORCE CSI WEB FORCE CSI
2-7 2044 0.34 4-8 -2144 0.22
2-8 -2144 0.22 4-9 2044 0.34
3-8 4723 0.79
4-8-6
I0-4-5
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
documents such as ICBO #1607.
Permanent bracing is required (by others) to
prevent . Sea HIB-91
ANSI/TPI r1-1995nor/toppling
ANSI/TPI 1-2002. and
2-PLYI Nail w/10d BOX, staggered (per NDS)
in: TC- 2/ft BC- 4/ft WEBS- 2/ft
4-1-2 3.4-2 i 3-4-2 4-1-2 1
4-1-2 7-5-4 10-9-6 14-10-8
7-5-4 1 7-5-4 I
2-PLYS 1 2 3 4 5
REQUIRED 700 -7.00�
5.B
2
DnN •
UPLIFT REACTIONS)
Support C&C Wind Non -Wind
1 -341 lb
2 -341 lb
HORIZONTAL REACTIONS)
support 1 -136 lb
support 2 136 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed Yes, Importance Factor a 1.00
Truss Location Not End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length a 99.00 ft, Bldg Width 50.00 ft
Mean roof height = 22.35 ft, mph = 90
TPI Standard Occupancy, Dead Load = 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area = 206 sqft
----------LOAD CASE #1 DESIGN LOADS---------------
Dir L.Plf L.Loc R.Plf R.Loc LL/T
TC Vert 85.00 0- 0- 0 85.00 14-10- 8 0.8
BC Vert 607.71 0- 0- 0 607.71 14-10- 8 0.6
5-10-2
SHIP
IO-4-5
a==== Joint Locations =__==
1 0- 0- 0 6 0- 0- 0
2 4- 1- 2 7 4- 1- 2
3 7- 5- 4 8 7- 5- 4
4 10- 9- 6 9 10- 9- 6
5 14-10- 8 10 14-10- 8
2-"
2-"~-i
�
14-10-8
6 7 8 9 10
4-1-2 3-4.23.4-2 4-1-2
1 1/ 3/2004
4-1-2 7-5-4 10-9-6 14-10.8
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 114" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Chk: BJS
Dsgnr• DGM
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 36.00 psf
TC Dead 7.50 psf
DurFacs L=1.15 P=1.15
Rep Mbr Bnd 1.00
TRUSWAL
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
SYSTEMS
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal softwae,
'ANSVrPI 1', WrCA I'- Wood Truss Council of America Standard Design Responsibilities, 'HANDLMG INSTALLING AND BRACING METAL
BC Dead 7.50 psf
Design Spec iRC
1101 N. Great S.W. Pkwy.. Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and 'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofiio ]hive,
It It 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 50.00 psf
Segn T6.4.12 - 011
Madison, Wisconsin 53719 The American Forest and Paper Association (AFPA) is located at
Ll"
Job Name: PHO-BARZEE Truss ID: A Qty: 2 Drwg: I
BRG X-LOC RRACT SIZE REQOD TC 2x4 DFL #1 & Btr.
1 0- 2-12 619 5.50" 1.50" BC 2x4 DFL #1 & Btr.
2 8- 3- 1 127 S.50" 1.50" WEB 2x4 DFL STUD
3 8- 3- 1 268 S.50" 1.50" SCAB 2x4 DFL #1 & Btr.
BRG REQIIIREMNTS shown are based ONLY ASCE7-98 SNOW LOAD DESIGN CRITERIA:
on the truss material at each bearing Pg = 35 psf, Ce = 1.0, I - 1.0, Ct = 1.00
SCAB(s) (cross -hatched area) to be same size
TC FORCE AXL BND CS1 and grade as chord to which it is attached.
1-2 -849 0.00 0.23 0.23 Use 2 scabs (1 ea. face) if indicated. Use
2-3 -45 0.00 0.25 0.25 10d nails @ 3" O.C. staggered, per NDS,
3-0 -3 0.00 0.00 0.00 plus clusters if shown. Do not splice scab
unless noted otherwise.
BC FORCE AYL BND CSI
4-5 825 0.12 0.17 0.29
5-0 O 0.00 0.00 0.00
WEB FORCE CSI WEB FORCE CSI
2-5 -853 0.22
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
and ANSI/TPI and are reported in available
documents such as ICBO #1607.
Mark all interior bearing locations.
Install interior support(s) before erection.
Permanent bracing is required (by others) to
prevent rotation/toppling. See HIB-91 and
ANSI/TPI 1-1995 or ANSI/TPI 1-2002.
Shim bearings (if needed) for req. support.
4-10-12
4-10-12
2. g-
2-10-0
8.5.13
3-7-1
8-5-13
UPLIFT REACTIONS) :
Support C&C Wind Non -Wind
1 -227 lb
2 -76 lb
3 -61 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed Yes, Importance Factor - 1.00
Truss Location - Not End Zone
Hurricane/Ocean Line - No , Exp Category = C
Bldg Length - 99.00 ft, Bldg Width - 50.00 ft
Mean roof height - 20.89 ft. mph - 90
TPI Standard Occupancy, Dead Load - 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area = 24 sqft
----------LOAD CASE #1 DESIGN LOADS---------------
Dir L.Plf L.Loc R.Plf R.Loc LL/T
TC Vert 0.00 0- 0- 0 141.48 7- 0-13 0.8
TC Vert 42.50 7- 0-13 42.50 8- S-13 0.9
BC Vert 0.00 0- 0- 0 24.97 7- 0-13 O.0
BC Vert 7.50 7- 0-13 7.50 8- 5-13 O.0
2-0-14
2-7-10
SHIP
MAX DEFLECTION (span) :
L/999 IN MEM 4-5 (LIVE)
L= -0.07" D= -0.03" To -
===== Joint Locations =====
1 0- 0- 0 4 0- 0- 0
2 4-10-12 5 8- 5-13
3 8- 5-13
8-5-13
8-5-13 11 / 3/2004
OVER 3 SUPPORTS
All plates are 20 gauge Truswal Connectors unless preceded by "NIX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 7116" = V
WAIWTNG Read all notes on this sheet and a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
give
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFaes L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 psf
Rep Mbr Bnd 1.00
noted Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
SYSTEMS
envi nnmerit that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.50 psf
Design Spec IRC
'ANSI/TPI 1','WTCA 1' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
1101 N. Great S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and MIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onoftio Drive.
DC 20036.
TOTAL 50.00
Seqn T6.4.12 - 0
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington,
psf
1.0"
IJob Name: PHO-BARZEE Truss ID: J2 Qty: 4 Drwg: I
BRG Y-Lot: REACT
SIZE RBQ*D
TC 2x4 DFL #1 & Btr.
Plating spec : ANSI/TPI - 1995
1 0- 2-12 363
5.50" 1.50"
BC 2x4 DFL #1 & Btr.
THIS DESIGN IS THE COMPOSITE RESULT OF
2 1-10- 0 74
5.50" 1.50"
IRC/IBC truss plate values are based on
MULTIPLE LOAD CASES.
3 1-10- 0 29
5.50" 1.50"
testing and approval as required by IBC 1703
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
BRG REQUIRMONTS shown are based ONLY
and ANSI/TPI and are reported in available
Pg - 35 psf, Ce = 1.0, I = 1.0, Ct - 1.00
on the truss material
at each bearing
documents such as ICBO #1607.
Mark all interior bearing locations.
Shim bearings (if needed) for req. support.
Install interior support(s) before erection.
TC FORCE AXL BND CSI
1-2 13 0.00 0.03 0.03
2-0 -5 0.00 0.00 0.00
BC FORCE AYL BND CSI
3-4 24 0.00 0.03 0.03
4-0 0 0.00 0.00 0.00
2-02-0-12-1
2-0-12
3.0 —
UPLIFT REACTION(S) :
Support C&C Wind Non -Wind
1 -136 lb
2 -36 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed = Yes, Importance Factor = 1.00
Truss Location = Not End Zone
Hurricane/Ocean Line - No , Exp Category = C
Bldg Length - 99.00 ft, Bldg Width = 50.00 ft
Mean roof height = 20.27 £t, mph = 90
TPI Standard Occupancy, Dead Load - 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area a 4 sqft
3-4
0-10-1 0-10-1
T
0-3-14 1-3-13
1 SHIP
2-0-0
2-0-12
MAX DEFLECTION (span) :
L/999 IN MEM 3-4 (LIVE)
Lo 0.00" D= 0.00" To
===== Joint Locations ===a=
1 0- 0- 0 3 0- 0- 0
2 2- 0-12 4 2- 0-12
2-0-12
2-0-1-0-12 11 13I2004
OVER 3 SUPPORTS
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 0132" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsilnifity is assumed for dimensional accuracy. Dimensions
Dsgnr• DGM
'
•
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFacs L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50
Rep Mbr Bnd 1.15
rested. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
psf
SYSTEMS
environment that will cause the moisture content of the wood to exceed 190/6 and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spaeing 2- 0- 0
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software.
BC Dead 7.50
Design Spec IRC
'ANSI/TPI 1', 'WTCA 1' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
psf
1101 N. Great S.W. Pkwy., Artington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036,
TOTAL 50.00 psf
Seqn T6.4.12 - 0
00"
Job Name: PHO-BARZEE Truss ID: J3 Qty: 4 Drwg: I
BRG Y-LOC REACT SIZE REQ'D TC 2x4 DFL #1 & Btr. Plating spec : ANSI/TPI - 1995
1 0- 2-12 463 5.50" 1.50" BC 2x4 DFL #1 & Btr. THIS DESIGN IS THE COMPOSITE RESULT OF
2 3-10- 0 150 5.50" 1.50" IRC/IBC truss plate values are based on MULTIPLE LOAD CASES.
3 3-10- 0 53 5.50" 1.50" testing and approval as required by IBC 1703 ASCE7-98 SNOW LOAD DESIGN CRITERIA:
a BRG REQUIREMENTS shown re based ONLY and ANSI/TPI and are reported in available Pg = 35 psf, Ce = 1.0, I - 1.0, Ct = 1.00
on the truss material at each bearing documents such as ICBO #1607. Mark all interior bearing locations.
Shim bearings (if needed) for req. support. Install interior support(s) before erection.
TC FORCE AXL BND CSI
1-2 32 0.00 0.17 0.17
2-0 -5 0.00 0.00 0.00
BC FORCE AYL BND CSI
3-4 53 0.00 0.14 0.14
4-0 0 0.00 0.00 0.00
300
UPLIFT REACTION(S) :
Support C&C Wind Non -Wind
1 -157 lb
2 -75 lb
This truss is designed using the
ASCE7-98 Wind Specification
Bldg Enclosed Yes, Importance Factor = 1.00
Truss Location = Not End Zone
Hurricane/Ocean Line a No , Exp Category = C
Bldg Length = 99.00 ft, Bldg Width = 50.00 ft
Mean roof height = 20.52 ft, mph = 90
TPI Standard Occupancy, Dead Load = 14.5 psf
Designed as Main Wind Force Resisting System
and Components and Cladding
Tributary Area a 8 sgft
4-0-1 2�
4-0-12
MAX DEFLECTION (span) :
L/999 IN MEN 3-4 (LIVE)
L- -0.01" Do -0.01" To -
__=== Joint Locations =====
1 0- 0- 0 3 0- 0- 0
2 4- 0-12 4 4- 0-12
1-4-1
1-4-1
3-4
1-9.13
10-3-14
SHIP
z-0-0
4-0-12
3 4
4-0-12
11 / 312004
OVA 32SUPPORTS
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
Scale: 13t16" =1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job:.EJ.
WO: BATT-BARZEE
This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer
Chk: BJS
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' DGM
'
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 35.00 psf
DurFacs L=1.15 P=1.15
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TRUSWAL
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 7.50 psi
Rep Mbr Bnd 1.1 S
noted Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
SYSTEMS
environment that will cause the moisture content of the wood to exceed l9•/" and/or cause connector plate corrosion. Fabricate, handle, install
'Joint
BC Live 0.00 psf
O.C.Spacing 2- 0- 0
and brace this truss in accordance with the following standards: and Cutting Detail Reports available as output from Truswal software,
BC Dead 7.50
Design Spec IRC
'ANSI/TPI l', 'WTCA I' - Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
psf
1101 N. Groat S.W. Pkwy., Arlington TX 76011
PLATE CONNECTED WOOD TRUSSES'- (HIB-91) and IUB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofiio Drive,
Seqn T6.4.12 - 0
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 50.00 psf
D2n
Job Name: PHO-BARZEE
Truss ID:
J4
Qt : 17
Drw :
BRG S-LOC REACT SIZE REQ'D
TC
2x4 DFL #1 & Btr.
Plating spec : ANSI/TPI - 1995
RESULT
OF
UPLIFT REACTIONS)
Support C&C Wind Non -Wind
1 0- 2-12 560 5.50" 1.50"
BC
2x4 DFL #1 & Btr.
THIS DESIGN IS THE COMPOSITE
2 5- 9- 4 300 5.50" 1.50"
WEB
2x4 DFL STUD
MULTIPLE LOAD CASES.
1 -171 lb
2 lb
BEG REQUXREMENTS shown are based ONLY
ASCE7-98 SNOW LOAD DESIGN CRITERIA:
1. 0, Ct 1.00
IRC/IBC truss plate values are based on
testing and approval as required by IBC 1703
-93
This truss is designed using the
an the truss material at each bearing
Pg
End
= 35 psf, Ce = 1.01 I a a
verticals designed for axial loads only.
and ANSI/TPI and are reported in
available
ASCE7-98 Wind Specification
TC FORCE AXL BND CSI
Extensions above or below the truss profile
documents such as ICBO #1607.
Bldg Enclosed = Yes, Importance Factor a 1.00
1-2 50 0.00 0.42 0.42
(if
any) require additional consideration
Truss Location = Not End Zone
Hurricane/Ocean Line = No Exp Category a C
(by
others) for horiz. loads on the bldg.
,
Bldg Length a 99.00 ft, Bldg Width = 50.00 ft
ND
BC FOR CB AYL sND csi
FORCE
Mean roof height - 20.76 ft, mph a 90
3-4 O.0.30 0.30
TPI Standard Occupancy, Dead Load - 14.5 psf
Designed as Main Wind Force Resisting System
WEB FORCE CSI WEB FORCE Css
and Components and Cladding
2-4 -3 0.04
Tributary Area = 12 sgft
09"
66-"
6-0-0
300
'j-z
2-"
6-M
2-3-10
SHIP
=a=== Joint Locations
1 0- 0- 0 3 0- 0- 0
2 6- 0- 0 4 6- 0- 0
6-0-0 6-0-0 11 / 3/2004
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 518" =1'
a?,�
TRUSWAL
SYSTEMS
1101 N. Great S.W. Pkwy., Arlington TX 76011
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building component not taus system It has been based on specifications provided by the component manufacturer
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
arc to be verified by the component mufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
an
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
'ANSI/TPI 1', VTCA I'- Wood Truss Council of America Standard Design Responsibilities, 'HANDLING INSTALLING AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES' - (HIB-91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onoflio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
Eng. Job:.HJ.
Chk: BJS
Dsgnr' DGM
'
WO: GATT-BARZEE
TC Live 35.00 psf
TC Dead 7.50 psf
BC Live 0.00 psf
BC Dead 7.50 psf
TOTAL 50.00 psf
DurFacs L=1.15 P=1.15
Rep Mbr Bnd 1.15
O.C.Spacing 2- 0- 0
Design Spec IRC
Sean T6.4.12 - 0