HomeMy WebLinkAboutSTAFF REVIEW - 04-00199 - 107 Star View Dr - New SFRCWY OF
REXBURG
AWKICns rnnmr COWUNur
Review Action
June 15, 2004
P.0 Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Permit Number: 04 00199
Project Name: Barzee/SFR
Project Type: Single Family Residential
Review Item
Actions Required for Approval
Approved
Building Department Review
Complies with approved Site Plan Review
06/15/2004
Exiting Review
06/15/2004
Height and Area Review
06/15/2004
Mechanical Review
06/15/2004
Interior Environment
Office window is nearly 24" from interior door. It
06/15/2004
must be at LEAST 24" from door or be
tempered.
Structural Review
The 46' long garage wall exceeds the maximum
length of 35' between braced wall lines (front
W A= T—
and back) allowed for by code. edesign`
exf
Truss Details need to be changed from a 30 psf
live load to 35 psf (before framing).
Energy Conservation Compliance Review
By inputing R-values in both the Cavity and
Cont. column you claim to be installing R-76 in
WA -Tr --
the attic, R-42 in the main & upper walls and R-
_
36 in the basement. Please redo REScheck.
Use the cavity column where insulation is
placed between framing members. Also select
Rexburg for the city.
Parcel #'s RPRHDVY703