REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release le
Data filename: Untitled.rck
PROJECT TITLE: Eric Barzee
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
DATE: 06/ 16/04
COMPLIANCE: Passes
Maximum UA = 460
Your Home UA = 418
9.1 % Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 2: Vinyl Frame:Double Pane with Low-E
Door 2: Solid
Door 3: Glass
Wall 2: Wood Frame, 16" o.c.
Window 3: Vinyl Frame:Double Pane with Low-E
Basement Wall 1: Solid Concrete or Masonry
Wall height 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Window 1: Vinyl Frame:Double Pane with Low-E
Door 1: Solid
Furnace 1: Forced Hot Air, 78 AFUE
o y 0 0I,>;
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
1378
38.0
0.0
41
1640
21.0
0.0
80
155
0.300
47
56
0.300
17
21
0.300
6
1440
21.0
0.0
74
136
0.300
41
1476
13.0
0.0
78
92 0.300 28
21 0.300 6
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000IECC
requirements in REScheckVersion 3.5 Release le (formerly MECchecli) and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release le
DATE: 06/ 16/04
PROJECT TITLE: Eric Barzee
Bldg.
Dept.
Use
I Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation
I Comments:
I
I Above -Grade Walls:
[ ] 1 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation
I Comments:
[ ] 1 2. Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation
I Comments:
I
I Basement Walls:
[ ] 1 1. Basement Wall 1: Solid Concrete or Masonry, 9.0' ht/8.0' bg/9.0' insul,
I R-13.0 cavity insulation
I Comments:
I
I Windows:
[ ] 1 1. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.300
1 For windows without labeled U-factors, describe features:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
[ ] 1 2. Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.300
1 For windows without labeled U-factors, describe features:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
[ ] 1 3. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.300
1 For windows without labeled U-factors, describe features:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
I
I Doors:
[ ] 1 1. Door 2: Solid, U-factor: 0.300
1 Comments:
[ ] 1 2. Door 3: Glass, U-factor: 0.300
1 Comments:
[ ] 1 3. Door 1: Solid, U-factor: 0.300
1 Comments:
I
I Heating and Cooling Equipment:
[ ] 1 1. Furnace 1: Forced Hot Air, 78 AFUE or higher
I Make and Model Number
I
I Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
I leakage must be sealed.
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
I with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Vapor Retarder:
Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
I Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
1 of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
I Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 'F must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1 "
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
I" and Less
1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)