Loading...
HomeMy WebLinkAboutCONCRETE TEST 32 - The Grove at Thomson FarmsFile name: 20001SB06222021EJB F0548D47-2223-4996-84C2-6061DBCA6744 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 33.0 Project Name: The Grove Test Location: South sidewalk of building #7, east sidewalk of building # 4, and west sidewalk of building # 5. Client: Stillwater Equity Partners Admixtures: MP 322, MA AE 90 Ticket Number: 278068 Contractor: Headwater's Construction Supplier: Walters Mix Number: 192 Date: 5/25/2021 Cylinder Log #: 249 Field Test Results: Set #: 1 Slump (inches): 4.8 Slump Maximum (in): Entrained Air (%): 4.80 Entrained Air Spec. (%): Concrete Temperature (°F): 64 Ambient Temperature (°F): 52 Unit Weight (PCF): 140.16 Tested By: Y. Kabwika Date: 5/25/2021 Picked Up By: Yannick Kabwika Date: 5/25/2021 Time: 10:00 AM Max, Min Temperature 64, 43.3 Previous Test Results: Cylinder ID: Break Age:Break Date: Diameter (in): Area (in^2: Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/1/2021 4.00 12.56 51125 4070.46 3000 Type 4 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/22/2021 4.00 12.6 68,145.0 5408.3 3,000.0 Type 6 C 28 6/22/2021 4.00 12.6 66,730.0 5296.0 3,000.0 Type 6 D 28 6/22/2021 4.00 12.6 65,815.0 5223.4 3,000.0 Type 4 Second Break Average: 5309 Date: 06/22/2021 Reviewed By: E. Vail Signature: