HomeMy WebLinkAboutCONCRETE TEST 32 - The Grove at Thomson FarmsFile name:
20001SB06222021EJB
F0548D47-2223-4996-84C2-6061DBCA6744 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
20001
Cumulative Test Load Amount:
33.0
Project Name:
The Grove
Test Location:
South sidewalk of building #7, east sidewalk of
building # 4, and west sidewalk of building # 5.
Client:
Stillwater Equity Partners
Admixtures:
MP 322, MA AE 90
Ticket Number:
278068
Contractor:
Headwater's Construction
Supplier:
Walters
Mix Number:
192
Date:
5/25/2021
Cylinder Log #:
249
Field Test Results:
Set #:
1
Slump
(inches):
4.8
Slump
Maximum
(in):
Entrained Air
(%):
4.80
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
64
Ambient
Temperature
(°F):
52
Unit Weight
(PCF):
140.16
Tested By:
Y. Kabwika
Date:
5/25/2021
Picked Up By:
Yannick Kabwika
Date:
5/25/2021
Time:
10:00 AM
Max, Min Temperature
64, 43.3
Previous Test Results:
Cylinder
ID:
Break Age:Break
Date:
Diameter
(in):
Area
(in^2:
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/1/2021 4.00 12.56 51125 4070.46 3000 Type 4
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/22/2021 4.00 12.6 68,145.0 5408.3 3,000.0 Type 6
C 28 6/22/2021 4.00 12.6 66,730.0 5296.0 3,000.0 Type 6
D 28 6/22/2021 4.00 12.6 65,815.0 5223.4 3,000.0 Type 4
Second Break Average:
5309
Date:
06/22/2021
Reviewed By:
E. Vail
Signature: