HomeMy WebLinkAboutSTAFF REVIEWS - 04-00176 - 112 Star View Dr - New SFRf -EXBUf' -G-.-
FY
f i
May 21, 2004
Permit Number: 04 00176
Project Name:
Project Type:
Review Action
SFR Rocky Mtn/Greene
Single Family Residential
Review Item
Building Deparimen# Review
Exiting Review
Height and Area Review
.'lien'l1 Review
Complies with approved Site Plan Review
Interior Environment
Structural Review
Energy Conservation Compliance Review
Parcel #`s RPRHDVY7010060
Actions_ Required for Approval
Maximum distance on a dryer vent is 25 ft
(reductions also applied to burns in vent).
Where is dryer exhausting to?
Don't forget the Layout inspection. Setbacks
are measured to the EAVES.
Braced wall lines .at garage are too far apart
(>35 ft). No Braced walk panels an back of
dining room bay window. Needs redesigning or
engineering for these items.
Truss details will be required before framing
insp.
Need REScheck compliance report.
P-0 Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (2D8) 359-3020
Fax (208) 359-3022
Approved
05/20/2004
05/20/2004
05/20/2004
05/20/2004
05/20/2004
August 20, 2004
Permit Number: 04 00176
Project Mame:
Project Type:
Review Action
SFR Rocky Mtn/Greene
Single family Residential
Regrew Item
Building Department Review
Exiting Review
Height and Area Review
Mechanical i+
Complies with approved Site Plan Review
Interior Environment
Structural Review
Energy Conservation Compliance Review
Parcel #'s RPRHDVY7010060
Actions Required for Approval
Maximum distance an a dryer gent
(reductions also applied to turns in
Where is dryer exhausting to?r
is 25 ft
vent).
Engineering recieved 8/13/04 for garage
{nothing for dining extension}. Framing must
comply with engineered design or must be
approved by engineer if different. Changes
redlined on dining bay must be followed to pass
frame inspection since if has not been
engineered.
Errors an REScheck compliance report.
19 E. Main .
Rexburg, Idaho 83440
Phone {2D8} 359-3020
Fax (2Q$) 359-3622
05/20/2004
I I #
05/20/2004
05/20/2004
05/20/2004
08/16/2004
08/17/2004