HomeMy WebLinkAboutRESCHECK - 04-00169 - 874 Widdison Ln - RemodelRESCIleck Compliance Certificate 1995 MEC REScheckSoftware Version 3.5 Release le Data filename: C:Trogram Files\Clheck\REScheck\Untitled.rck PROJECT TITLE: Garage Remodel Project CITY.- Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family DATE: 05/06!04 DATE, OF PLANS: April 13, 2004 I I-,', ROJECT DESCRIMON- FkemOdel gam9e to rnAe a singie car garage, and a hobby room., DESIGNER/WNTRACTOR: Leishman Construction COMPLIANCE: Passes Maximum UA = 41 Your Dome UA = 40 2.4% Better Than Cade (UA) Ceiling 1: flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. WindOw 1. Vinyl Frame:Doubie bane ' Door 1: Solid 3 A Floor 1: All -I& mood Jo*st/Truss:Qver Unconditioned Spare Permit Number Cross Glazing Area or cavity Cont. or Door Perimeter R -Value R-Vajue U.Factor UA 234 40.0 a.0 7 20S 14.0 0_0 13 18 0.300 5 21 0.350 7 234 30.0 0.0 8 COMPLIANCESTATEMENT.- The proposed building design descfibed here is consistent with the building plans, spec�fica#ions and other calculations srxbmitted With the permit application. The proposed building has been designed to meet the X995 MEC 3 requirements in REScheckVersion 3.5 Release Ie (formerly MECchec4 and to comply with the mandatory requirements listed is the REScheck1nsPCCU-0,n Cbecklist. Date .) --� � 4r REScheck Inspection Checklist 1995 MEC RIES checkSOftw= Version 3.5 Release I e DATE: 05/06/04 PROJECT TITLE: Garage Remodel Project Bldg. Dept. Use Ceffings: I. Ceiling I-% Flat Ceilingr Scx Truss,, cavity insulation Comments: Above -Grade Walls* I. Wall I- Wood Fame,, 16" . } 10 R-14.0 cavity inm1ation Co :rants: Windows.0 ., I. Window I.- Vinyl Frame:Double Pane, U -factor: 0.300 For windows without labeled U -factors, describe features- # Panes Frame TYPe----. Thermal Break? [ l Yes [ ] No Comments: Doors* L Door I: Sohd, -factor; 0.350 commcnts- Floors, 1. Floor'. A"-WWdJ0iSt/TMSS:0VCf UncOnditioned Space., IZ-30.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that axe sources of air leakage must be sealed. Recessed lights must be 1}Tyke IC rated, or 2} iftstalled inside an appropriate air -dight assembly with a 0.5" clearance from combustible materials. Tf non -IC rated, the fixture muni be instaed with a 3" clearance from insulation. Vapor Retarder, Required an the warm -in -winter side of all nnn"vented framed ceilings,, wars, and f1mrs. Materials ldentffication,, Materials and equipment must be identified so that campii,ance can be determined. Manufacturer manuals for ail installed heating and cuvling �q�ipm�nt and service water heating equipment must be provided. Insulation R values and glazing U -factors must be clearly marked on the building plans or specifications. Duct Insulation, Ducts in unconditioned spacers must be insulated. to R-5. Ducts outside the building must be mated to R-8-.0. Duct Congraction* AH ducts must be seated with mastic and- fibrous backing tape. Pressure -sensitive tape may be used for fibroin ducts. Duct tape is not permitted., The HVAC system must pravide a means for balancing air and water system. VO is Temperature Controls& Thermostats. are required for each separate HVAC system. A manual or automatic means to partially restnct or shut off the heading and/or coming input to each zone or floor shall be provided. � GrCulating Hot mater Systems: [ � � Insulate circulating hot water pipes to the levels in Table I. Swimming Pools: j ) f Aril. heated swurtmin9 fmi S mist havc an vnfoff heater switch and require a cover unless over 200,Zo � of the heating energy is dram non-depletable sources. Poul pumps require a time clock. f � Heating and Cooling Piping %sulation1w � ] I HVAC piping conveying fluids above 120 T or chilled fluids below SS IF must be insulated to the � bevels in Table 2.