Loading...
HomeMy WebLinkAboutCONCRETE TEST 31 - The Grove at Thomson FarmsFile Name: 20001FB06222021EJB BFE55DEA-1C95-4845-BFE1-9F4E398B7F67 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 20001 Cumulative Test Load Amount: 13.5 Project Name: The Grove Test Location: North valley gather of building number 4 Client: Stillwater Equity Partners Admixtures: MP 322, MA AE 90 Ticket Number: 1755 Contractor: Kevin Virgin Construction Supplier: Walters Ready Mix Mix Number: 192 Pour Date: 6/15/2021 Cylinder Log #: 329 Field Test Results: Set #: 1 Slump (inches): 2.2 Slump Maximum (in): 5.0 Entrained Air (%): 3.80 Entrained Air Spec. (%): 6.00 Concrete Temperature (°F): 68 Ambient Temperature (°F): 61 Unit Weight (PCF): 142.57 Tested By: Y. Kabwika Date: 6/15/2021 Time Tested: 6:30 AM Picked Up By: Yannick Kabwika Date: 6/15/2021 Time: 9:15 AM Max, Min Temperature 84.2; 49.1 File Name: 20001FB06222021EJB BFE55DEA-1C95-4845-BFE1-9F4E398B7F67 2 Initial Break Results: Cylinder #: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Break Type: Required 28 day Strength (psi): A 7 6/22/2021 4.00 12.56 57,740.0 4597.13 Type 3 3,000.0 Date: 06/22/2021 Reviewed By: E. Vail Signature: