Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 04-00155 - Tuscany Place Apartments - Site PlanyCITY F 1Z..,.-EXBUPs,.G., April 19, 2004 Permit Number: 04 00115 Project Name.,* TUSCANY PLACE Project Type: Review Action Multi Family Residential Review Item wilding Department. Review Accessibility Review Complies with approved Site Plen Review Building Tyke Compliance Exiting Review Height and Area Review Energy Conservation Compliance Review Building Code Firs Compliance Review Mechanical Review Structural Review Interior Environment P.0 Box 280 12 North Center Street Rexburg, Idaho 83443 Phone (208) 359-3020 Fax (208) 359-3022 1On4_"e_ iced for Aoprova.l -Approved Aid lowered sinks and work spares as per 04/01/2004 redlEned drawings., Also change the pantry doors to a z' 10" minimum width. Provide an accessible route is the public right-of-way, Provide accessible roue to the publi4 c right -of- 04/01/2004 way as per the redlined drawings. B uilding #4 does not meet requirements and will not be VA included with review at this time. Building is a Type VB nonrated building. At 3 04/01/2004 stories it is required to be sprinklered. Provide 5/8" Type X drywall on both sides of 04/01/2004 entry walls as redlined on the plans. Area and height meet code requirements for 04l01/2004 this type of building with the installation of an approved sprinkler system. The energy requirements need to be calculated 04/01120Q4 using the Multiply Family criteria. End wads between buildings must be built as 04l0112004 one hear firewalls due to the distance betvveen them. The party, walls must be built so that their integrity is continuous from foundation to roof sheeting. Provide plumbing details prier to frame inspection. Provide mechanical details prior to frame 0410112Q04 inspection. Include lavation and size of furnace and water heater locations. Provide structural stamped drawings for 04/01/2004 foundation and shearwalls, ASAP. 04!01/2004 CITY OF e F f G f EXBU �*R. 42W a ANIFRICAS Review Action April 1 9, 2004 Permit Number: 04 00115 Project Name: TUSCANY PLACE Project Type: Multi Family Residential Review Item__... Actio Fire Department Review Floor Area Fire Access Roads Required Fire Flow Commercial Cooking Standpipes Alarm Systems Fire Extinguishers Automatic Fire Extinguishing Systems Water Supply Other Comments s pal APPROXIMATELY 15,504 SQUARE FEET PER BUILDING IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 3250 GPM/THREE HOURS ALARM PLAN SUBMITTED AND WILL 13E ACCEPTED AFTER CONSULTATION WITH OMNI ALARM. FIRE EXTINGUISHERS NOT SHOWN. NEED TO PROVIDE A MINIMUM OF ONE 2AIOBC EXTINGUISHER IN EACH UNIT MOUNTED IN AN ACCESSIBLE LOCATION IN OR NEAR THE KITCHEN AREA. f have been informed by Mayor Larsen to allow this project to continue. 1 have been provided with hydrant calculations and a set of preliminary plans from 3D Fire Protection for the sprinkler system. A state -approved set of plans has not been provided as of this date. Site has two working fire hydrants an site as of this date. One of those hydrants is an extra one installed at the construction company's discretion. Hydrant flows have been provided. Additional hydrant is stated to be installed prior to project have occupancy permit issued. F was void by Chief Larsen that Sainsbury Gonstruction has picked up a lock box authorization- form dor this project. O Box 280 12 North Center Street Rexburg, Idaho 83440 Phone {208} 359-3020 Fax (2a8) 359-3022 WJ-L". s e 03/24/2004 03/24/2004 03/24!2004 03/24/2004 03/24/2004 04/01/2004 04/06/2004 04/06/2004 04/06/2004 04/06/2004