Loading...
HomeMy WebLinkAboutCHECKLISTS - 04-00144 - 785 Pinehaven St - New SFRRE,SIDENTI.Aid P AN CHECKLIS Date y_2 7 Oe -1 Project: Job Address: .7950"' BuildingermPit Number Zoning: Lf) P... � Number of Stories: Floor Area: r. • Description: 2 es Valuation: Permit Fee: Plan Check Fee: Tae fallowing �co�nn:��nts based on the ,z0uu edrtion ot`the Intemational Residential Code should be resolved before a bulld,1119 permit is issued. This correction list is not a building permit. The approval of plans and specr�cat�ans does not permit the viala�.on of any section of the Intemational Residential Code yr any federal, -T IN or local r�gulairons. - PLAN CHECK A. Plans ..,,//'To Scale lee,plot Plan Legzblek-W Y &Iood Plain r" Floor / Foundation Plan -/-Section shawIng construction details /All Building Elevations Design Criteria (shall be zdentifed an pians as ,Truss Calculation Sheets /`FO�Floor Joist Details Energy Calculations (IDN -320 & Ch 11) Wind - 85 m.p.h., Snow - 35 ib. Per sq ft.) B. Zoning (check one - in some cases LDR2 and MDR may apply) LDR ,/LDRl Lot area — LDR- 12,000 sq. ft. min. (width. 80 ft. min) (width60 ft. min.).(LDRI du lex - 10 ,000 sq. ft. min.) C.O/V Sirlgle Famit F _Duplex (LDRI } - Cil use ermit? D. /Set Backs (takenfrom eaves) wont set back (3`2 ft. from curb) �Note,*, 60% nain of front yard green Rear set back (T,--,D-R 25 ft. & LDRI 20 ft.) & LDRI- 8, 000 sq. ft. ITI /Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6'ml*n,) /O'Building-Hei-Rhtaxi(mmum 30 ft.) E. Footings - P�rap�ex Size has peer Table 403. 1, 1 , -z. Rebar (2-#4 continuous) use 1500 psf unless soil type is known, Table 401.4.1 for soff beari.irig) ZGTirder Support Footings (size as per Table 502.3,4(2)) Footing Depth (3 6 " below ffiiishedgrade) F. Foundatio-n oundation wads Nv1 rebar (city ordinance) oun.datian Draina�ye (foundations an sift soil sh�.11 be designed per Section R405) >( 'Waterproofing has per section. R406) ;� qc-P ve%nt1'Iat;nn1T-nq„lnttnn =1 gin_ -fit_ nor 150 sf.(With moisture barrier I sf._per 1500 Sq- ft.) A --- j _ .. Nvithin 3' of each cornu- (insulate walls no vents re e "a) /Seismic Hold Downs and Braced Wall Panels (R602,10) Gradinor (all yards shall slope away from house) Vinc�ovv Wells clear hori�onial and vertical dimensions of 24" min.) (ordiance) G. � -ame Braced Walls (R602) /Ofloors(chebearingad capacity of joists as per Ch 5) Joists Under Load Bearing Partitions (shall be doubled as per Ch 5) �►� Girders SCh 5) //OCCantl* levers (check for blocking,,re�nforcem.ent, s a�C1n and s- an drawings) (manuf inst instr) ZFloor Sheathing (SCh 5) Exterior Wall (Ch 6) /"OLLoad Bearing Walls (Ch 6) Bearing Wall Window and Door Headers (design as per Tables 602.7.2) (Ch 6) ire Blocking has per Section 602.8) ( �Roaf Trusses (desi,gqed according to Section 802.9 and braced as per manufacturer) 35 # Snow and 85mph windy (Local Conditions) Rafter and Truss Hold -Downs (des'gned according to Section 802. 10 or truss manufactwer) (R802) ZRio'of Sheathing (as per Sect -ion 803) (R803) Attic Access (provide 22" x 3"'0" min. access where attic clear height exceeds �O"){R$06} H. Exte '*or coverincy- .vope� i * ffig I ZBrick or Stone Veneer �. oof Covering and Ventilation Roof Ventilation has per -R806) .�Asphalt Shingles Slate Shingles, Metal, Clny, Tile or Concrete Wood a_ J. Firewalls .�Garage (a one -dour fire-resi,stive separation between garage & house 21 ,Door from (R321) 'mood Shades Garage to House (13 14" solid wood, exterior metal or 24 min. rated fire door required) >("'Two Family Dwelling Separation (1 hr. firewall)(R321) K. General Requirements House lumbers (R325) Light and Ventilation (des"gn as per Section R303) ZMinimum Room. Areas done _room at least 12+D �f. other habitable rooms min. of 70 sf, min habitable rooms dimer. of 7 ft} (R304) Windows a� vvl�� of side hinged door frame (R308) ZI; indow Egress (R31 0) Exit Door(one exitdoor'' t' must be �� wide) (Section R31 1) ings �a min. 3' x 3' �andzn� req�.ixed at each side of e ess doors .�h thresh�Tolds not mare than 11I2" higher than landing)(R311) at bottom of stairs."* No req. at fop if door DIN sing over stairs} (-R311) Stair Rise / Run (7 3/411 max. rise & 10" (6' 8" min.) handrails (34"to 3811 mm. tread)0000' Stair Width (3611 min), �Stai.xtivay Headroom above stair nvsing)(R31 14 /000 S�a�rway Protectoon(enclosed accessi bye space under stairs shad be Havered with t/2" drywall)(R311) �GuardraiIs�Handz-ails x(36" height, mandatory at 30" drop or 4 or more rsers and 4" sphere ere max. )(R3 1 f } /eeSmoke Detectors beach bedroom and common area and one on each level) [R 3I7) �M�echa��i.cal VentilatingSystems in---� bathrooms, laundry rooms and sxlar rooms)(R303) L. E ergy Percentage of glazing to wall area (Type A-1�1 5% max or use IE C Tables 502.2.4(x) Vapor side of walls ceiling and floors IIECC 502.1*1 retarder onivvarm, "in winter i Water Hester heat traps I CC 504.7 Zbuct sealing and insulation IRC 11[i3.3 4 . - Plans match R and U values on Energy Calc's,