Loading...
HomeMy WebLinkAboutRESCHECK - 04-00144 - 785 Pinehaven St - New SFRREScheek Compllanee Certificate 2000 IECC Permit Number Checked By/Date RESclzeck5oftwarc Vcrsian 3.5Rcicase 1� Data file-im-ne: CADocuments and ScLLin,gs\Admini9rdtur\MY DocunieiitsIRESclieck\Lin.den,,rok CITY: Rexburg STATE-. lclaho HDA; 869 3 CpNSTRUCTION TYPE, r. Single Family DATE: 04119/04 DATE OF PLANS: April 19, 2004 PROJECT nESCRIF'TTQAI: Brad & Britncy Taylpr Oakbrook Subdivision I -A)[' 42 Re•burg. TD 8,14-40 DESIGNERfCON'TR A.CTC)R� Kartchner Homes P.O. Box ?48 Rexburg, ilk 83440 C0NIPLIANCE - Passes Maximim UA — 617 Your Horne UA _ 55$ 9.6% Better Tfi-m Code (TJA) celag 1 _% Flat Ceiling or Scis�or Tmss VV$1t 1: Wood Frame, 16" v.c. Window I: Vinyl Fraine.-Double. Pane Doo -r I: Glass Door 2; Solid Floor 1:All-Wood J rus:Over Unconditioned Space Floor : All -Wood JoisYTruss,.Over Outside Air Wall 2: Wood Frame. 16" o . Wind 1 Frame -.Double Panc *Floor 23! Slab-0n-Gradc-_LjnheatW lnsulakn depth-, 3.0' r-,ufnacc 1 :]Forced Hot Air. 80 AFUE a 7,7 Cross Gluing Area or Cavity Cont. 4r Door ?Cn'meter RwValue R -Value CJ -Factor UA 1045 40-0 0.0 so 1084 21.4 0.0 53 98 0.400 39 33 0,400 13 20 0,400 8 516 40.0 0.0 13 709 21.0 0.0 38 42 4.400 .17 483 8.0 346 COWLIANCE STATENENT: The proposed building desigii desuibod hire isconsistent wig the building plans, Vccifications., and other calc atts submitted with tlic permit application. The proposed building has bccn d,lsxgned to nieet the 2400 IECC requircmcnls in REScheckVusion 3_5 Rclezise le (fortnerly 11E0:1zec4 and to comply with the mandatory rcquirenrents Usted in the REScheckdnspecdon ChecklistIq 911-d 010/100'd 990-1 H019929EVI S3AOH IVINMiN00-W01� WEZV:60 V0GZ=6[mJdY BuiI.derlDesigncr 911-1 0 1 0/i0D d 990-1 k802992991 SaHOH IVIN3NIINOO-WOld wp24:80 tooZ-81-jdy REScheck Inspection Checklist 2000 IECC RE5check5oftware Versl'oia.1.5 Release le DATE: 04119104 Bldg. � DCpL Use [ � I I. Ceifing 1: Flat Ceiling OF Srissor Truss, k-44.0 cavity tnsuiativR � CommentswL � Above-Crade Wills. ] � 1 _ Wall I : Wood Frairc, 16 IT Ro-21.0 cavity insulation commenisl [ j � 2. Wall 2; wQad Frame. 16" o_c.R-2 1 .0 cavity insulation � Comments-. � Windows: � 7 i I. Window L Vinyl FraMeDoible Fane. Uwfactor: 0.40U f For windaws w4hout lobeled U -factor& describe features, � # Panes Frame Type rmal Break? Yes j ] No j C0111MC atS: l l I 2. Window 2: Vinyl Framc-Double Pane. U-hictor.- a.400 � �`or �vi�d�w� wi�tp�1, labeled U factars, describe features: � # Panes Frame T�p�Thcrmal Sneak? Yes No � Doors: I I l 1. Door 1: Glass., IJ-faclorl 4.400 commentsd ] i z. Door 2: solid: U-factork 0.400 j commentsm Floors: � � 1 1. Floor 1: All -Wood Joist/Truss,-,Over Unconditioned Space, R-44. 0 cavity insulation commerits..'­ _M j ] j 2. Floor 2, All -Wand JoiStfTruss 0ver Outside Air, R-40.0 cavity insulation j Comments: 3. Floor 3. Slab-,OnwGrade:Unheated, J. O'insulat"�y■i depth, � R-8.0 continuous ixsilafion � Slab "nsui tion to ex -tend down from t1iQ tip of the slab to at least 10 ft. OIC dawn to at � lust the bottom of the sIqb dift.ri bon- zvntaUy for a iai.al distance of 3.4 ft. � Exten',orm'sulation must have a rigid. opaque, weather -resistant protective covering that � overs the exposed (above-gTade) insulation and ex-teods at least b in. below grade. � Heating and Coolm'g Equtoment: [ � � 1. Furnace 1: Fofccd Hot Air.. 80 AFUE or higher � Make and IvivdeI Nu Huber J Air Leakagc: ] j Joints, penetmtions., and all otter such openiiigs in the building envelope that �.ne sources of air leahge must bc sealed. [ ) I F &%. lights mud be 1} Tvpe IC -rated. or 2} installed inside an appropriate air -tight awembly � Vriih a 0.5" dearartce from combustible ma#eriahs. If non�IC rated, the fix -hire must bc ire .1ed with a 9 ll-d 0 10/E00d 990-1 Y9025515EYl SMOH 171N3NI1N0O-walj weEY:60 400i-6t-adtl 3"clearance frena instdation � Vapor Retarder: Acquired an Am warnZ-in-winlerr side of Al non vcnted framed ceilings, wails, end t) oQrs. � M:iterii:►]s Identification, � ] y Materials and equipment Must be installed in accor&nce with the manufacti=- r`S instaUation instmetions, � ] � Materials and cqu1pment mini be identffied so that compliance can be deterrm'nc- d. l � Manufaoturer mantmls for all installed hcating and cQoLing equipment and 5eMce water heating � equipment must be provided- Insulation R-values. glazing TAT -factors, and heating equipment CCiCiertcy must be dearly marked on the buiid%ng plans or specifications, J Insr�lativn:Duct Ducl.s in uzxcanditioued spaces must be insulated to R-5. Ducts outside the building must be insulate to R-8.0. � duct Construction: C ] I All joints. sums, and r.onncctions must be ply fastcncd with welds. baskets, inastics j (adhasroves�, mastic-pluS-cmi dc�d-fabric, or iapes. Duct type is not pezmitteii { .ExcepflQrr_ Continuously welded and locking-tyN lo dinal joints aa.r1 sea= on ducts � operating at less than 2 irL w.g. (500 Pa). [ � � Ducts shall be supported cvery ] 0 feet or in a,ccardancc with the rranufachirer's instruc .6 Onsir � ] � Cooffiig ducts with exterior insulation rust be covered with a vapor retarder_ a � Air filicrs arc required in the reiiirii. sir systom. The HVAC System must provide a, Incans for balancing air a�.iti water systems. � Temperature Controls: � l � 'nicnrios[ats ars required for each scp=te HVAC system. A manual or automatic mcms to f parUally restxict or stint off the hca6ng and/or gaoling input to each zone or floor shall be provided. C I SeMee Water Heating: � ] I Water heaters with vertical pipe riWrs must have a heal trap on both the inlet and auilct urlm the water heater has an integral heat trap or is part of a circulaOng system. � I In�ilate circulating hot water pipes to the levels in Table i. j CircuiRting Hot Water SyAems; � ] � Insulate circulating hot water pipes to the levels in Table 1. E { Swimming Pools; 1 F PJI heated switYu�g pools must have an on1off heater switch and nqu= a cover urtless over 20% J of the heating energy is From nvn-ciepletabic saurccs. Pooh pumps require a dime clock. Heating end Coaling Piping insulation: � ] j HVAC pipm_g conveying huids above 105 T or chillcd fluids below 55 °P must be insulated to the j levels in Table 2. 9 1 l -d 0 10/400' d 990-1 V901992991 SMOH IVION11NOO-MOld W29:68 4002-81-adV Table I: Minimm InsukVion ThickneiTufor Ciriculafing Hot Water Pipes. Insulatiori TbJCk1e55 in Inches by Eipc Sizes Hcated Water Non-Circulatina Riumouts Circulating! Mainen aY'tti Rnnrnits Temperature ( F) 170-180 1,40-160 100-130 UP to V, Up to 1.25" va 0.5 1.0 o=5 o.s O�5 0-5 1,5" to 2,0" ovell " 1.5 1.0 L5 0.5 1.60. Table 2.' Minimum Insulan-on 7'ftic:krress for RvAc Fip�.s. Fluid Tem -P. Insuhtion Thickness in Inches PxPing astem Types F) Hca#ing Systems Low Pressure/Temperatare Low Temperat-m Steam Condensate (for feed water) Carling Systems chilled Water. Reirigerant and Brine 211 bouts Pipe Sizes Fq end Less 1,25« to12-5"'10 " 201-250 I,Q 16D 1.S 2.0 124-200 0.5 1.0 1,D 1.5 Any 1.4 1.0 1.5 2.0 Below -40 1.0 1_0 1.5 1_5 NOTES TO FIELD (Building DeparLme n -t USC Qn.1y) 9I1 -d 0 10/900 d 990-1 V80l55l9EVl S340H 1V1N3NI1NDO-Mi kaoZ-B [-add