Loading...
HomeMy WebLinkAboutRESCHECK - 04-00114 - 637 Palmer Circle - New SFRREScheck Compliance Certificate 2000 IECC Generated by REScheck-Web Software PROJECT TITLE: Walker Residence CITY: Rexburg STATE: Idly LIII. 8693 CONSTRUCTION TYPE: Single Family SATE: 03/23/04 DATE OF PLANS: 3-15-04 PROJECT DESCRIPTION: Residential DESIGNER/CONTRACTOR: Ryan Meikle -Certified Draftsman JEMCO -Construction LLC Maximum UA = 410 Your Home UA = 317 22.7% Bever Than Code (UA) Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter ®Value l -Value U -Factor ISA Ceiling 1. Flat or Scissor Truss 1900 44.0 0.0 51 Wall 1 Wood, Frame, 24" o.c. 1638 24.0 0.0 72 Door 1: Solid 40 0.120 Door : Glass 20 0.550 11 Z.12- Window I -_ Vinyl Frame, 2 Fane Low -E 188 0,350 66 Basement Wall I ` Solid Concrete or Masonry 1376 11 Wall height: .' Depth below rsale, 7.0' Insulation depth; ,' Window ` Vinyl Frame, 2 Pane Low -E 80 0.350 28 l r 1: All -Wood Joist/Truss Joist/Trussover Outside .1 r 5.3 32.0 0.0 2 Furnace I .- Forced Hot (Non -Electric), 98 AFUE CONTLIANCE ST NMT } The proposed building design described here is consistent with the building plans, specifications, and other calci ions submitted with the permit application. The proposed building has been designed to meet the QOQ` CG requirements in REScheck-Web and to comply with the mandatQrt-y rer�uirem�nts lie �n the � eck Inspection Checklist. BuilderlDesigner Date - — REScheck Inspection Checklist 2000 IECC Generated by REScheck- Web Software DATE.- 03/23/04 PROJECT TITLE: Walker Residence Bldg. Dept. Use I Ceilings: 1, Ceiling 1: Flat or Scissor Truss, 8-44.0 cavity insulation Comments: Above -Grade Walls: 1. Wall L., Wood Firame, 24" o.c., R-24.0 cavity m'sulat ion Comments.. ]Basement Walls: I. cement Wall 1: of Concrete or Masonry, 8.0'ht/7.0'bg/8.0'insu1, -11.0 cavi ty in su I ati on Comments: Windows: 1 Window 1: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.350 For Windows without labeled U -factors, describe features; # Panes Frame Type Thermal Break? Yes Comments: 2. Window 2: Vi�nyl Frame, 2 Pane w/ Low - E, U -factor: 0.350 For windows without labeled U -factors, describe features: ft, Panes Frame Type Thermal Break?. Yes[ Comments: Do0ors. 1. Door 1: Solid, U -factor: .0.120 Comments,-, 2. Door 2: Glass, U -factor: 0.550 Comments: ] No Floors: 1. Floorl: All -Wood Jit Tru over Outside Air!, R-32.0 cavity insulatim Comments: 0 Heating and Cooling Eqwpment: I. Fury ace 1: Forced Hot Air (Non -Electric), 98 AFUE or higher Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.. � � Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.51t clearance from combustible materials. If non -IC rated, the fixture must be installed with a 1 3" clearance from insulation. Vapor Retarder: Required on the warm - in -winter side of all non -rented framed ceilings, walls, and floors. Materials Identification: Materials and equipment mist be installed in. accordance with the manufacturer's installation instructions. Materials and equipment mush be identified so that compliance can be determined. Manufactures manuals dor all installed leafing and cooling equipment and service water heating equipment must be provided. Insulation R -values, glazing U -factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation S .ducts in unconditioned spaces must be insulated t R-5. Ducts outside the building must be insulated t -.. Duct r ui ori All joints, scams, and connections rust be securelyfastened with welds, gaskets, mastics (adhesives), mastic- luT d -fabric. or tapes., Duct tape is not. permitted. Exception,, Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 .. Ducts shall be supported every 10 feet or in accord with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retard er . Air filters are required in the return air system. j The HVAC system must provide a means for balancing air and water systems. � Temperature Controls. � Thermostats are rEquired for each separate HVAC system. A manual or automatic means to l partially restrict or shut off the heating and/or coaling input to each zone or floor shall be provided. � Service Water Heating: ng: � Wader heaters with vertical pipe risers mist have a heat trap on both the inlet and outlet unless the � water heater has an integrali heat trap or s part of a circulating system. � Insulate circulating hat water pipes to the levels in Table 1. � Circulating Hat Water Systems: j Insudate circulating hot water pipes to the levels in Table 1. � Swimming Pools: � All heated swimming pools mush have an on/off heater switch and require a cover unless over 20°/Q 0 of the heating energy is from non-depletable sources. Pool pumps require a time clock. Hewing and Cooling Piping Insulation: { � � HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the � levels in Table 2. Table I. Alin inmm Insulatio'n Th i ku ess fo r G rcu la dng Hot Water Pipes. ■ 2: Minimum insulation Thickness for HVfiC Pipes. Fluid Temp. insulation Thickness in Inches Piping System Types Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water,, Refrigerant, and Brine 201-250 120-200 Any --. Below 40 NOTES TO FIELD (Building Department Use Only) P Sizes 11 Runout° I " and Less 1.2511 .11 t : 11 " to '# 1.0 1. Insulation T r kn in Inches by Pipe Sizes Heated Water Non-Circulatin Runouts fr u l tingy Mains , and Runouts Temperature Up to III it to 1.2511 1.51f to 2,01v Over " 1.70-180 0.5 1.0 1.5 2.0 140-160 0.5 0.51.0 1.5 100-130 0.5 0. 1-0 2: Minimum insulation Thickness for HVfiC Pipes. Fluid Temp. insulation Thickness in Inches Piping System Types Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water,, Refrigerant, and Brine 201-250 120-200 Any --. Below 40 NOTES TO FIELD (Building Department Use Only) P Sizes 11 Runout° I " and Less 1.2511 .11 t : 11 " to '# 1.0 1. 1-5 2.0 0.5 1.0 1.0 1. 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1. 1.0 1.0 1.5 1.5