Loading...
HomeMy WebLinkAboutREVIEW ACTIONS - 04-00112 - Wingers Restaurant*iii6 CFFY OF a, I EXBU April 8, 2004 Permit Numbers. 04 00112 Project Name: Project Type: Wingers Restaurant Commercial New Review Action Review Item.�_. Actions Required for Firs Department Review � , Required Fire Flow Water Supply Fire Access Roads Other Comments warm systems Firs Extinguishers Automiatc Fire Extinguishing Systems Standpipes Commercial hooking Fire Department Siteplan Review 1 Approval Parcel #'s REQUIRED FIRE FLOW IS 1750 GPM/TWO HOURS. WITH A FIRE HYDRANT WITHIN 500 FEET. / 000W 40 Y�w \j a-ird 7WPIF OCCUPANCY REQUIRES A "K" TYPE FIRE EXTINGUISHER MOUNTED IN KITCHEN AREA IN ADDITION TO A MINIMUM OF 2A10BC FIRE EXTINGUISHERS MOUNTED WITHIN TRAVEL DISTANCES. OCCUPANCY REQUIRES A FIRE SUPPRESSION SYSTEM IN THE EXHAUST HOOD. SUBMITTALS., CONTRACTOR NAME ADDRESS, AND TELEPHONE NUMBER REQUIRED PRIOR TO BUILDING PERMIT BEING ISSUED. iliLe, � Cwc��„t s�e E�14Vk dor t�i� P.�rr►� B 14, L � � � ✓E,� SS�u e-.5 12 North Center Street Rexburg, Idaho 8344 Phony: (2(7$) 359-3020 Fax (2D8} 359-3422 03/23/2004 03/23/2004 03(23/2004 03/23/2004 03/23/2004 03!23/2004 03/23/2004 03/23/2004 A C]TY OF [��EXBU R,G. N1 J'Y April 29, 2,004 Permit Numbers. 04 00112 Proje;ct Name: Project Type: Review Item Wingers Restaurant Commercial New Building Department Review Accessibility Review Height and Area Review Complies with approved Site Rlan review Building Code Fire Compliance Review Building Type Compliance Exiting review Water and Sewer Service Plumbing Sewer Drain Review Plumbing Storm Drain Review Mechanical Review Interior Environment Review Action Actions Required for Approval Accessible Parking signs are shown on page A7.02 but not on site plan. Idenfify the location on the site plan. The code allows a VB building used as a restuarant to be 6000 sq. ft. and this buidling is about 360a. This building 'i's one story as allowed by code. A new site plan was provided. The previous site pian did not match the building construction plans. identify an site plan the location of the handicap parking space signs. The plansidentify open space around the building. Exterior dire seperatian is not required. Sprinklers are not required. Building has been reviewed as Type VB non- rated construction. Provide panic hardware on egress doors as per the 2000 International Building Code (113C) Section 1003.3.1-9. Emergency lighting, is required at exits as per !BC Section 1003.2.11. The lighting plan on page E9.01 identifies emergency lights in the restrooms and the kitchen. Please identify in the dinging area. Grease trap required to have 311 gent. Wader softners recycling system requires floor sink. Floor sink should not discharge into grease interceptor. Discharge into sanitary sewer. Provide manufacture's certificate of compliance for mechanical components as per !BC Section 1621.3.5 Provide the fame spread and srnvkedeveloped index,of the interior paneling identified as "bead 12 Forth Center Street Rexburg, fdaho 83440 Phone (248) 359-3020 Fax (208) 359-3022 04/21/2004 04/27/2004 Le l�iI�L! 04/27/2004 04/28/2004 04/28/2004 04/29/2004 04!29/2004 r 115 04/29/2004 04/29/2004 CITY Or f 'EXBUPs..G. NNIFRICA5.5 FAMILY COMMUNI FY April 29, 2004 Permit Number: 04 00112 Project Name: Project Type: Revi-ewAtem Wingers Restaurant Commercial New Plumbing Potable Water Review Structural Review Energy Conservation Compliance Review Parcel #'s Review Action ions Required f board" includ ing the paint -or 'finish associated with it. The plans an page S2.02 indicate that the Contractor is to coordinate the placement location and the weights of the HVAC roof units with the joist manufacturer. Please provide the engineering documentation for the joists. Include the locations and the weights of the roof units. The foundation is, not designed as per local requirements. The frost depth is a minimum of 36" deep. Please redesign the foundation accordingly. Provide lighting evaluation for the International Energy Conservation Code (IECC).. RO Box 280 12 North Gent r Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (20$) 359-3022 04/29/2004 04/29/2004 CITY OF f EXBUP��G - April 29, 2004 Permit Number: 04 00112 Project Name: Wingers Restaurant Project Type. Comm-erdal New Review Item Fire Department Review Required Fire Flow Other Comments Fire Extinguishers Automatic Fire Extingul'shing Systems Alarm Systems Standpipes 'mater Supply Fire Access Rosas Fire Department Siteplan Review 1 Approval Commercial Cooking Review Action ions Ream r Apmoval REQUIRED FIRE FLOW IS 1750 GPM/TWO HOURS WITH A FIRE HYDRANT WITHIN 500 FEET. OCCUPANCY REQUIRES A "K" TYPE FIRE EXTINGUISHER MOUNTED IN KITCHEN AREA. IN ADDITION TO A MINIMUM OF 2A1013C FIRE EXTINGUISHERS MOUNTED WITHIN TRAVEL DISTANCES. Must install 3" Vent off of grease interceptor New drawings submitted show change in parking around structure. Please provide "No Parking Fire Lane" signs and paint the curb red in the front. New drawings submitted show change in parking around structure. Please provide "No Parking Fire Lane" signs and paint the curb red in front. OCCUPANCY REQUIRES A FIRE SUPPRESSION SYSTEM IN THE EXHAUST HOOD. SUBMITTALS, CONTRACTOR NAME, ADDRESS, AND TELEPHONE NUMBER REQUIRED PRIOR TO BUILDING PERMIT BEING ISSUED. P-0 Box 280 12 North Center Street Rexburg, Idaho 83444 Phone (248) 359-3020 Fax (208) 359-3022 Ap.proved 03/23/2004 03/23/2004 03/23/2004 03/23/2004 03/23/2004 03/23/2004 03/23/2004