HomeMy WebLinkAboutRESCHECKS - 04-00091 - 32 Mill Race Road - New SFRREScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release le Data filename: Untiticd.rck CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family DATE: 02/27/04 COMPLIANCE: Passes Maximum UA = 451 Your Home UA = 365 19.1%Better Than Code (UA) Permit Number �c�laars �S Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral Ceiling (no attic) 1745 38.0 0.0 47 Wall 1: Wood Frame, 16" o.c. 950 21.0 0.0 47 Window 1: Vinyl. Frame:Double Pane with Low-E 120 0.350 42 Wall 2: Wood Frame, 16" o.c. 1422 21.0 0.0 72 Window 2: Vinyl Frame:Double Pane with Low-E 105 0.350 37 Door 1: Solid 40 0.350 14 Door 2: Glass 18 0.350 6 Basement Wall 1: Solid Concrete or Masonry 1136 21.0 0.0 48 Wall height: 8.0' Depth below grade: 6.5' Insulation depth: 8.0' Window 3: Vinyl Frame:Double Pane with Low-E 48 0.350 17 Door 3: Solid 20 0.400 8 Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 108 0.0 0.0 27 Furnace 1: Forced Hot Air, 90 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release le (formerly MECchec,) and to comply with the mandatory requirements listed in the RES check I nspection Check I i st. Builder/Designer Date Pfl A(= Ov i N-r,_,r-1 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC Generated by REScheck-Web Software PROJECT TITLE: Trevin Ricks Home CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family DATE: 03/10/04 DATE OF PLANS: 2/19/04 PROJECT DESCRIPTION: Three Story Single Family DESIGNER/CONTRACTOR: Trevin Ricks COMPLIANCE: Passes Maximum UA = 360 Your Home UA = 283 21.4% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral 2000 38.0 0.0 54 Wall 1: Wood Frame, 16" o.c. 1414 21.0 0.0 65 Door l: Solid 36 0.400 14 Window 1: Vinyl Frame, 2 Pane w/ Low-E 240 0.350 84 Basement Wall 1: Solid Concrete or Masonry 1104 21.0 0.0 50 Wall height: 8.0' Depth below grade: 6.5' Insulation depth: 8.0' Floorl: All -Wood Joist/Truss over Uncond. Space 610 38.0 0.0 16 Furnace 1: Forced Hot Air (Non -Electric), 90 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck-Web and to comply with the mandatory requirements ste �theREScheck Inspection Checklist. �, ��_ � �, Builder/Designe Date i REScheck Inspection Checklist 2000 IECC Generated by REScheck- Web Software DATE: 03/10/04 PROJECT TITLE: Trevin Ricks Home Bldg. Dept. Use I Ceilings: [ ] ( 1. Ceiling 1: Cathedral, R-38.0 cavity insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation j Comments: I I Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/6.5' bg/8.0' insul, R--21.0 cavity insulation Comments: I I Windows: [ ] I 1. Window 1: Vinyl Frame, 2 Pane w/ Low E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No I Comments: I I Doors: [ ] I 1. Door 1: Solid, U-factor: 0.400 Comments: I I Floors: [ ] ( 1. Floorl: All -Wood Joist/Truss over Uncond. Space, R-38.0 cavity insulation Comments: I Heating and Cooling Equipment: [ ] I 1. Furnace 1: Forced Hot Air (Non -Electric), 30 AFUE or higher I Make and Model Number I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a I 3" clearance from insulation. I Vapor Retarder: [ ] I Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R values, glazing U factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R 5. Ducts outside the building must be insulated to R 8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)