HomeMy WebLinkAboutRESCHECK - 05-00488 - 358 Oaktrail Dr - New SFRu — v —
0500488
358 Oaktrail Dr-SFR
��
REScheck Compliance Certificate Necked By/Date
2003 IECC
REScheck Solfware Version 3.6 Release 2
Data filename: C:\Documents and Settings\Administrator\My Documents\REScheck\Jobs\Idaho\Oakbrook Lot 13.rek
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
WINDOW WALLRATIO:0.15
DATE: 12/22/05
DATE OF PLANS: December 22. 2005
PROJECT DESCRIPTION:
Doug Phillips
Oakbrook Subdivision
Lot: 13
358 Oaktrail Drive
Rexburg. ID
DES TGNER /C ONT RA C T OR:
Kartchncr Homes
3456 F. 17 Street
Suite 210
Ammon City, ID 83406
PROJECT NOTES:
2x6 Walls,
E28
COMPLIANCE: Passes
Maximum UA = 297
Your Home UA = 248
16.5"1,; Better Than Code (UA)
Gross
Glazing
Area or
Cavity Cont, or Door
Perimeter
Value R-Value U-Factor 1L
Ceiling L Flat Ceiling or Scissor Truss
1184
40.0 00.0 34
Wall I: Wood Frame, 16" o.c.
1301
21.0 0.0 64
Window- 1: Vinyl Framc:DoublePane
102
0.350 36
Door 1: Glass
33
0.350 12
Door 2: Solid
37
0.200 7
Basement Wall 1: Solid Concrete or Masonry
1301
13.0 0.0 73
Wall height: S.0'
T) pth below grade: 7.0'
Insulation depth: 8.0'
Windom- 2: Vinyl Framc:Double Pane 64 0.350 22
Furnace 1: Forced Hot Air, 90 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent ,%ith the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck-=V -ion 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirement, lifted in the !jESrhecW(nspection Checklist.
$uilder'Designer Date 12
i - ----
l■�
REScheck Inspection Checklist
2003 IECC
REScheck Software Version 3.6 Release 2
DATE: 12/22/05
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation
Comments:
Above -Grade Walls:
( 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7.0' bg/8.0' insul,
R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Vinyl Frame:Double Pane, U-factor: 0.350
For windows without labeled U-factors, describe features:
4 Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
( 1 2. Window 2: Vinyl Frame:Double Pane, U-factor: 0.350
i For windows without labeled U-factors, describe features:
4 Panes__ Frame Type Thenntal Break? [ ] Yes [ ] No
Comments:
Doors:
( 1. Door 1: Glass, U-factor: 0.350
Comments:
[ ] 2. Door 2: Solid, U-factor: 0.200
1 Comments:
Heating and Cooling Equipment:
[ ) 1. Furnace 1: Forced Hot Air, 90 AFUE or higher
Make and Model Number
Air Leakage:
[ ) Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
( Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Skylights:
"UO/
` ( ] Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.
Vapor Retarder:
[ ] Required on the warm -in -winter side ofall non -vented flamed ceilings, walls, and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-1 1.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R-11.
( ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
( ] Where exterior walls are used as plenums. the wall must be insulated to R-11.
insulation is not required on return ducts in basements.
Duct Construction:
[ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
[ ] All joints, sums, and connections must be securely fastened -Aith welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Erception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The I-IVAC system must provide a means fbr balancing air and water systems.
Temperature Controls:
[ ] Themiostats are required for each separate HVAC system. A manual or automatic means to
1 partially restrict or shut offthe heating and'or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
( ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
S,wzmming Pools:
( J All heated swimming pools must have an on/offhcater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] i NAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the
levels in Table_'.
4 Table l: Minimum Insulation Thickness for Circulating Hot Water- Pipes.
Insulation
Thickness
in Inches by Pipe Sizes
Heated Water
Non -Circulating
Runouts
Circulating Mains and Runouts
T eml2crature ( F)
Up to I"
Up to 1. 25"
1.5" to 2.0"
Over 2"
170-1 SO
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table ?: Afinimum Insulation Thickness fur MJAC Pipes.
Fluid Temp.
Insulation Thickness
in Inches
by Pig
Si
Pining, System Types
Range F
2" Runouts
1" and Less
1.25" to 2"
2.5" to 4"
Heating Systems
Low PressurelTemperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Ste,-un Condensate (fir feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Usc Only)