HomeMy WebLinkAboutRESCHECK - 05-00488 - 358 Oaktrail Dr - New SFRu — v — 0500488 358 Oaktrail Dr-SFR �� REScheck Compliance Certificate Necked By/Date 2003 IECC REScheck Solfware Version 3.6 Release 2 Data filename: C:\Documents and Settings\Administrator\My Documents\REScheck\Jobs\Idaho\Oakbrook Lot 13.rek CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW WALLRATIO:0.15 DATE: 12/22/05 DATE OF PLANS: December 22. 2005 PROJECT DESCRIPTION: Doug Phillips Oakbrook Subdivision Lot: 13 358 Oaktrail Drive Rexburg. ID DES TGNER /C ONT RA C T OR: Kartchncr Homes 3456 F. 17 Street Suite 210 Ammon City, ID 83406 PROJECT NOTES: 2x6 Walls, E28 COMPLIANCE: Passes Maximum UA = 297 Your Home UA = 248 16.5"1,; Better Than Code (UA) Gross Glazing Area or Cavity Cont, or Door Perimeter Value R-Value U-Factor 1L Ceiling L Flat Ceiling or Scissor Truss 1184 40.0 00.0 34 Wall I: Wood Frame, 16" o.c. 1301 21.0 0.0 64 Window- 1: Vinyl Framc:DoublePane 102 0.350 36 Door 1: Glass 33 0.350 12 Door 2: Solid 37 0.200 7 Basement Wall 1: Solid Concrete or Masonry 1301 13.0 0.0 73 Wall height: S.0' T) pth below grade: 7.0' Insulation depth: 8.0' Windom- 2: Vinyl Framc:Double Pane 64 0.350 22 Furnace 1: Forced Hot Air, 90 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent ,%ith the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck-=V -ion 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirement, lifted in the !jESrhecW(nspection Checklist. $uilder'Designer Date 12 i - ---- l■� REScheck Inspection Checklist 2003 IECC REScheck Software Version 3.6 Release 2 DATE: 12/22/05 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation Comments: Above -Grade Walls: ( 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7.0' bg/8.0' insul, R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane, U-factor: 0.350 For windows without labeled U-factors, describe features: 4 Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: ( 1 2. Window 2: Vinyl Frame:Double Pane, U-factor: 0.350 i For windows without labeled U-factors, describe features: 4 Panes__ Frame Type Thenntal Break? [ ] Yes [ ] No Comments: Doors: ( 1. Door 1: Glass, U-factor: 0.350 Comments: [ ] 2. Door 2: Solid, U-factor: 0.200 1 Comments: Heating and Cooling Equipment: [ ) 1. Furnace 1: Forced Hot Air, 90 AFUE or higher Make and Model Number Air Leakage: [ ) Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ( Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: "UO/ ` ( ] Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: [ ] Required on the warm -in -winter side ofall non -vented flamed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-1 1. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. ( ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ( ] Where exterior walls are used as plenums. the wall must be insulated to R-11. insulation is not required on return ducts in basements. Duct Construction: [ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. [ ] All joints, sums, and connections must be securely fastened -Aith welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Erception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The I-IVAC system must provide a means fbr balancing air and water systems. Temperature Controls: [ ] Themiostats are required for each separate HVAC system. A manual or automatic means to 1 partially restrict or shut offthe heating and'or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ( ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. S,wzmming Pools: ( J All heated swimming pools must have an on/offhcater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] i NAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the levels in Table_'. 4 Table l: Minimum Insulation Thickness for Circulating Hot Water- Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts T eml2crature ( F) Up to I" Up to 1. 25" 1.5" to 2.0" Over 2" 170-1 SO 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table ?: Afinimum Insulation Thickness fur MJAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pig Si Pining, System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low PressurelTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Ste,-un Condensate (fir feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Usc Only)