I have reviewed the Pinnacale drawings that you have provided me and have
identified the following discrepancies:
1. The total occlipant number for the upstairs i's greater than 99 and therefore two
sets of stars at least 44" wide are required for egress.
2. Provide details thatidentify how the requirements of SBC See ion 704.1 1 Will
be met.
3. The 2 -hour dears at the firewall must be self closing. Identify an the plans.
4. If building is not sprinklered, the maximum length of a dead. end hallway is
20' as per IBC Section 10 16.3. Nuke the necessary changes to the plans.
S. Are new footings required for the added floor loads? Do the walls that are
supporting the new floats have footings Winder.hem? If so, are they sized
adequately for the added loads? Provide details and calculations.
6. How is the HVAC being handled. Provide details.
7. Please respond to the requested review actions that were submztted by the Fire
Department Review (attached).
Please return two segs of revised plans. Let me know if I can be of any further
assistance. If you have any questions, please give me a call at 359-3020 ext. 324.
Val Christensen
Building Official
cc Brad Johnson
Josh,Stoddard
Val Christensen Bu-ildingOficial 19 E. Main Rexburg ID 83440 P. 0. Box 280 vale
@rexhurg. arg wwiv.rexbmtX. or
Phone . 3020 .t. ' Rax(206)359.3022
ITY OF
EXBURG
_--_C)W-
Amefica� Family Community
February 1, 2006
Permit Number: 05 00480
Project Name:
Project Type:
Review Item
Review Action
Pinnacle Security Remodel
commercial Remodel
Building Department Review
Interior Environment
Complies with approved Site Plan Review
Accessibility Review
Exiting Review
Building Code Fire Compliance Review
Structural Review
Height and Area Review
Building Type Compliance
Mechanical Review
_ Actions Required for Approqal
Wall and ceiling finishes must meet the
requirements of Section 803 of the IBC.
Adding 15% to the occupancy of the building
requires a new site plan be submitted.
An accessible women's restroom is required on
the ground floor. The men's restroom must be
made to be accessible. Provide details.
The West and center stairways must be a
minimum of 44" wide. Identify location of exit
signs and emergency exit lights. Identify two
new doors to the nursery as per !BC Table
1014.1. Entry doors at amain entrance must
swing in the direction of travel as per IBC
Section 1008.1.2'.
Building must be sprinklered. Adding the
additional space to the upstairs and changing
the occupancy of the building requires that the
building meet the requirements of the 2003
International Building Code (113C). Windows are
not allowed on the South wail due to the
location of the property line.
Provide structural details and calculations.
Idenfify,joist size and spacing. The struetural
engineer must identify haw all Loads will be
bandied. They include but are not limited to
footings for the new bearing walls that have
been created and existing wall seismic
considerations from adding a new floor
diaphram. Provide details stamped by a
licensed professional.
Area does not meet the requirements of the
code unless sprinklers are provided.
Building is V13 or VA
identify new HVAC at the new offices and other
spaces.
RO Box 280
19 E. Main St.
Rexburg, Who $3440
Phase (2(}8) 359-3020
Fax (208) 359-3022
W-, 0 fl!"T =
02/01/2006
CIT 1 0 F
EXB
TJRG-
-C)QV----
A
March 1, 2006
Permit Number: 05 00480
Project Name:
Project Type:
R
eview Action
Pinnacle Security Remodel
Commercial Remodel
Review Item
.. .. ..... ....:.. ....... Firl
..
iw
................
Required Fire Flow
'"mater Supply
Automatic Fire Extinguishing Systems
Standpipes
Fire cress Roads
Fire Exfinguishers
Commercial Cooking
Alarm Systems
ether Comments
Parcel #'s RPRRXB 103 745 10
bg
RO Box 280
19 F Mair St.
Rexburg, Idaho $344
Phone (2Q8) 359-3020
Fax (208) 3593022
Actions Reqmu re�lfo
r Ap pTova l
—Anproved
REQUIRED FIRE FLOW BASED ON
APPROXIMATELY 24,000 SQUARE FEET
TYPE IV IS 2750 GPM/TWO HOURS.
ESTABLISHED WITH EXISTING HYDRANTS
NOT REQUIRED
NOT REQUIRED
ESTABLISHED
FIRE EXTINGUISHERS NOT NOTED ON
SUBMITTED PLANS, PLEASE PROVIDE
MORE INFORMATION.
PLANS INDICATE A KITCHEN AREA. PLEASE
PROVIDE MORE DETAILS. AREA MAY
REQUIRE A HOOD SYSTEM WITH FIRE
SUPPRESSION.
MANUAL FIRE ALARM SYSTEM REQUIRED
AS OCCUPANCY LIMIT ON UPPER FLOOR
EXCEEDS 700 PERSONS. (IFC SECTION
907.2.2) PLEASE PROVIDE PLANS AND/OR A
LETTER OF INTENT FROM A LICENSED
FIRE ALARM COMPANY.
PLEASE PROVIDE DETAILS ON SWIMMING
POOL OPERATIONS (CHEMICAL USAGE,
HEATING, ETC.)PLEASE PROVIDE MORE
DETAILS ON NOTED ITEMS. IF THERE ARE
ANY QUESTIONS PLEASE CONTACT CHRIS
AT 705-1312 OR BRAD AT 716-1321.
0112812006
01/28/20-06
01 /28/2006
01/28/2006
01/28/2006
0
til
ITT
REXBURG
March 2, 2006
Permit Number: 06 00103
Project Norrie:
Project Type:
Review Action
Pinnacle Security -Site Plan
Site Plan Review
Review Item
Building De�ra�ttnen� Revir
Number of Parking Spaces
Fire Separation
Parking Configurative
Plumbing Review
Miscellaneous
Snow Storage
Parcel #'s RPRRXB 103 745 10
Avt_i�ons Require -d for A
rov
Parking meets requirements as long as the
exercise space is used as accessory to the
business portion of the building. If used other
than described above, then more parking may
need to be provided.
An easement on the property adjacent on the
North side has been provided to allow window
in the North wall of the. building.
The ADA van parking space requires 8wide
loading space adjacen# to it.
Replace the landscape strip between the curb
and the sidewalk. This area has been hard
surfaced in the past and should be restored to a
landscape area.
The snow storage identified for the front parking
lot does meet the 10% requirement.
R Box 280
1Main St.
Rexburg, Idaho 8344
Phone (2Q8) 359-3020
Fax (2Q$) 359-3422
A130m)ved
03/01/2006
03/01/2006
REVD
jx-L)LTRG
QV
February 1, 2006
0
ReviewActoon
Permit Number: 05 00480
Project Name: Pinnacle Security Remodel
Project type: Commercial Remodel
Review Item
Miscellaneous
Parcel #!'s RPRRXR10374510
ActionsRe�c aired for Ap.Vroval
P.0 Box 280
19 E. Main St.
Rexburg, Idaho 8344
Phone {20$} 359-3020
Fax (2Q8) 3593022
Plumbing fixtures must meet the requirements
of !BG Section 29Q2. Provide a new yet of
drawings that are stamped by a licensed
professional.
. a
,,. I TY OF
REXBURG
Apnmcals Family Communily
March 22, 2006
bg
Permit Number: 05 00480
Project Name:
Project Type:
Review Item
Review Action
Pinnacle Security Remodel
Commercial Remodel
Building Department Review
Interior Environment
Complies with approved Site Flom Review
Accessibility Review
Exiting Review
Building Code Fire Compliance Review
Structural Review
Height and Area Review
Building Type Compliance
Mechanical Review
Actions lReq-qtred
Wolf and ceiling finishes must meet the
requirements of Section 8Q3 of the IBC.
Adding 151J/0 to the occupancy of the building
requires a new site plan be submitted.
An accessible women's restroom is required on
the ground floor. The men's restroom must be
made to be accessible. Provide details.
The West and center stairways must be d-'
minimum of 44" wide. Identify location of exit
signs and emergency exit lights. Identify two
new doors to the nursery as per IBC Table�
1D14.1. Entry doors at main entrance must
swing in the direction of trace! as per IBC
Section 1008.1.2. V0AJLC-
P-0
Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (2p8) 359-3022
02/0
Building must be sprinkfered. Adding the
additional space to the upstairs and changing
the occupancy of the building requires that the
building meet the requirements of the 2003 ,,o'
International Building Cade (113C). Windows are
not allowed on the South wall due fn the l
location of the property line.
Provide structural details and calculations.
Identify joist size and spacing. The structural
engineer must identify how all loads will be
handled. They include but are not limited to
footings for the new bearing walls that have
been created and existing wall seismic
considerations from adding a new floor
diaphram. Provide details stamped by a V
licensed professional-
Area
does not meet the requirements of the
code unless sprinklers are provided.
Building is VB or VA
DfC
r1e, i P 0 /0 Lo; OeV
fIx�ir'rc�
P66t cr��yy�E
Identify new HVAC at the new offices and othPr
spaces.
I 1_4
I TY OF
I�EXBURG
- - -
Americ : � family Comm t4 n ily
March 22, 2006
0
Permit Number: 05 00480
Project Name:
Project Type;
review Item
Review Action
Pinnacle Security Remodel
Commercial Remodel
Fire, Department Review
Required Fire Flow
Water Supply
Automatic Fire Extinguishing Systems
Standpipes
Fire Access Roads
Fire Extinguishers
Commercial Cooking
Alarm Systems
Other Comments
Parcel #`s RPRRYB 1 X3745 I .0
Actions Required fo Val
REQUIRED FIRE FLOW BASED ON
APPROXIMATELY 24,000 SQUARE FEET
TYPE IV IS 2750 GPM/TWO HOURS.
ESTABLISHED WITH EXISTING HYDRANTS
NOT REQUIRED
NOT REQUIRED
ESTABLISHED
FIRE EXTINGUISHERS NOT NOTED ON
SUBMITTED PLANS, PLEASE PROVIDE
MORE INFORMATION.
P.0 Box 280
19 E. Main St.
Rexburg, Idaho 83440
Phone (2Q$) 359-3020
Fax (208) 359-3022
Aroved
. A
01/28/2006
01/28/2006
01/28/2006
01/28/2006
01/28/2006
PLANS INDICATE A KITCHEN AREA. PLEASE /J�� �,�n
PROVIDE MORE DETAILS. AREA MAY
REQUIRE A HOOD SYSTEM WITH FIRE
SUPPRESSION.
MANUAL FIRE ALARM SYSTEM REQUIRED ��NNAG G� ro
AS OCCUPANCY LIMIT ON UPPER FLOOR V 10� t�7F�K
EXCEEDS 100 PERSONS. (IFC SECTION °� tu• TIFE
/S
907.2.2) PLEASE PROVIDE PLANS AND/ORA PC01**#ft*i/ k VC,. ,_ .n
LETTER OF INTENT FROM A LICENSED,
FIRE ALARM COMPANY.
PLEASE PROVIDE DETAILS ON SWIMMING
POOL OPERATIONS (CHEMICAL USAGE,
HEATING, ETC.)PLEASE PROVIDE MORE
DETAILS, ON NOTED ITEMS. IF THERE ARE
ANY QUESTIONS PLEASE CONTACT CHRIS
AT 705-1312 QR BRAD AT 716-1321.
G� ryryL Y
? 2 pb _
-- I TY 0 F
EX -B
URG
CW--------
t U o
March 22, 2006
Permit Number:
Project Name:
Project Type:
Review Item
Miscellaneous
10
Review Action
0500480
Pinnacle Security Remodel
Commercial Remodel
.. _ Actions Re rovall
Plumbing fixtures must meet the requirements
of IBS Section 2902. Provide a new set of
drawings that are stamped by a licensed
professional.
Parcel #'s RPRRXB 103745 10