March 14, 2006
Permit Number; 05 00470
Project Name.
Project Type:
Review Item
Walgreens
Commercial New
Waste Water Grease Trap Form
Waste Water Application
Structural Review
Parcel #'s RPRRXB10370011
Review Action
Actions Required for AMroval
licensed architect or engineer.
The structural calculations do not contain thtelL
correct importance factors as per Table 1604.5
of the SBC. Allso, the snow load is identified as
30 lb/sq.ft. and should be changed to 35 ld/sq.
ft -HVAC roof top units must be fastened to
structure as per IBC Section 1621. On sheet
3101, special inspections are listed as not
being required for concrete. Special
inspections are required for the foundation sof
the building and also the high strength bolting.
Please provide a letter from the Special
Inspections firm that identifies all at the special
inspection to be perfromed and the frequency.
When a building was removed from the site, it
brings up quest -ions as to the quality of the
structural capacity of the soil The existence of
filly and debris is of concern. Provide
information that identifies that the necessary
investigations and safegaurds have been
performed. All footings must be a minimum of
3G" below grade.
P.0 Box 280
1 E. Main St.
Rexburg, Idaho 83440
Phone (2Q8) 353-3020
Fax (2D8) 359-3022
VL X
1 TY 0 F
f�E"URG
Ow
Americ6 Fel Community
March 14, 20Q6
Permit Number: 05 00470
Project Name: Walgreens
Project Type:
Commercial New
Review Itrem--
Fire
Departme-nt Review
Commercial Cooking
Standpipes
Required Fire Flow
Alarm Systems
Other Comments
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Review Action
—.--- Act i Qns Required for A�ravai
Parcel #'s RPRRXB 103 70011
N/A
N/A
See site pias Review.
Submit plans far review and submit letter of
intent. Plans are required to be approved before
installing the firs alarm system.
Lack box is required for this building. Forms are
available at Rexburg Madison County Fire
Department.
Spee si#e plan review.
dee site plan review.
No extinguishers shown an plans. Requires
2A10BC extinguishers as required by the
International Fire Cede.
Please submit letter of intent from contractor.
Plans are to be reviewed and approved by the
State Fire Marshall before installing.
Ro Box 280
19 E. Wn St.
Rexburg, Idaho 83440
Phone (2[i8) 359-3020
fax (208) 359-3022
A--pp-rQv--ed
12109/2005
12/09/2'005
•V
ITY OF
REXBURG
-� — 0&
March 14, 2006
Permit Number: 05 00470
Project Name:
Project Type:
I
Walgreens
Commercial New
Review item
Pubic Works Review
Public Works Review
Parte! #'s
RPRRXB 103 70011
Review Action
Ac#ions Required for Ap�royal
7 . The approval for the site amenities such as
lighting is not approved. The city is working thru
standards for benches, trees: tree grates etc. t
have no problem issueing a building permit at
this time. Details to be worked out at a later
date.
2. Submittals on site lighting will need to be
done according to the development code.
RO Box 280
Rexburg, Idaho 83440
Phone (2Q8) 359-3020
Fax (208) 359-302
Anoroved
01/17/2006
IT Y 0 F
REXBURG
_ QVFamily Cwnawnij�
me cas
---
March 14, 2006
Permit Number: 05 00470
Pro't
ject Name:
Project Type:
Walgreens
Commercial New
Review Item
Building Department Review
Plumbing Potable Water Review
Plumbing Storm Drain Review
Plumbing Sewer Drain Review
COMPlies with approved Site Pian
Review
Exiting Review
Hight and Area Review
Interior Environment
Water and Sewer Service
Accessibility Review
Mechanical Review
Energy Conservation Compliance
Jew
Building Type Compliance
Building Code Fire Compliance Review
Miscellaneous
Review Action
Act ions Required for A�pro�al
RO Box 280
19 E. Main St.
Rexburg, Idaho 8344
Phone (208) 3593020
Fax (2L}8) 359-3022
Water fines are required to tested and 12/0912005
inspected before capering. All water lines are to
be sized and installed according to the Uniform
Plumbing Code.
Roof drains and overflows are required to be 12/0-9/2pQ5
tested and inspected before covering. AIS roof
drains are to be sized according to the Uniform
Plumbing Code.
Drains are required to be tested and inspected 12/09/2005:
before covering.
Site plan has been reviewed. 01/10/2006
Meet the requirements of the 2003 International 01/10/20uo
Building Code (113C).
The height and area meet the requirements of 61/10/2006
the 113C.
All interior finishes must meet the requirements 0111012 UO
of chapter 8 of the IBC.
Water and sewer services are required to 01/� �12��6
tested and inspected before covering.
Identify handicap parking spaces (with
dimensions)on the site P12n.
Building is Type 1113. A ia s Must meet
the requirements of IBC Section 6p3. 1. Make
the necessary changes to plans.
Materials must meet the requirements of IBC
Section 603. Fire retardant treated lumber is
allowed in those uses indicated by IBC Section
603. 1. Identify the type of material used to
construct the tower floor.
ASI pages of the plans must be stamped by a