Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 05-00470 - Walgreens - New BuildingNQz I TY OF E I RXB G America's Fan; ly (r 0 x u�1 1y March 14, 2006 Permit Number; 05 00470 Project Name. Project Type: Review Item Walgreens Commercial New Waste Water Grease Trap Form Waste Water Application Structural Review Parcel #'s RPRRXB10370011 Review Action Actions Required for AMroval licensed architect or engineer. The structural calculations do not contain thtelL correct importance factors as per Table 1604.5 of the SBC. Allso, the snow load is identified as 30 lb/sq.ft. and should be changed to 35 ld/sq. ft -HVAC roof top units must be fastened to structure as per IBC Section 1621. On sheet 3101, special inspections are listed as not being required for concrete. Special inspections are required for the foundation sof the building and also the high strength bolting. Please provide a letter from the Special Inspections firm that identifies all at the special inspection to be perfromed and the frequency. When a building was removed from the site, it brings up quest -ions as to the quality of the structural capacity of the soil The existence of filly and debris is of concern. Provide information that identifies that the necessary investigations and safegaurds have been performed. All footings must be a minimum of 3G" below grade. P.0 Box 280 1 E. Main St. Rexburg, Idaho 83440 Phone (2Q8) 353-3020 Fax (2D8) 359-3022 VL X 1 TY 0 F f�E"URG Ow Americ6 Fel Community March 14, 20Q6 Permit Number: 05 00470 Project Name: Walgreens Project Type: Commercial New Review Itrem-- Fire Departme-nt Review Commercial Cooking Standpipes Required Fire Flow Alarm Systems Other Comments Water Supply Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Review Action —.--- Act i Qns Required for A�ravai Parcel #'s RPRRXB 103 70011 N/A N/A See site pias Review. Submit plans far review and submit letter of intent. Plans are required to be approved before installing the firs alarm system. Lack box is required for this building. Forms are available at Rexburg Madison County Fire Department. Spee si#e plan review. dee site plan review. No extinguishers shown an plans. Requires 2A10BC extinguishers as required by the International Fire Cede. Please submit letter of intent from contractor. Plans are to be reviewed and approved by the State Fire Marshall before installing. Ro Box 280 19 E. Wn St. Rexburg, Idaho 83440 Phone (2[i8) 359-3020 fax (208) 359-3022 A--pp-rQv--ed 12109/2005 12/09/2'005 •V ITY OF REXBURG -� — 0& March 14, 2006 Permit Number: 05 00470 Project Name: Project Type: I Walgreens Commercial New Review item Pubic Works Review Public Works Review Parte! #'s RPRRXB 103 70011 Review Action Ac#ions Required for Ap�royal 7 . The approval for the site amenities such as lighting is not approved. The city is working thru standards for benches, trees: tree grates etc. t have no problem issueing a building permit at this time. Details to be worked out at a later date. 2. Submittals on site lighting will need to be done according to the development code. RO Box 280 Rexburg, Idaho 83440 Phone (2Q8) 359-3020 Fax (208) 359-302 Anoroved 01/17/2006 IT Y 0 F REXBURG _ QVFamily Cwnawnij� me cas --- March 14, 2006 Permit Number: 05 00470 Pro't ject Name: Project Type: Walgreens Commercial New Review Item Building Department Review Plumbing Potable Water Review Plumbing Storm Drain Review Plumbing Sewer Drain Review COMPlies with approved Site Pian Review Exiting Review Hight and Area Review Interior Environment Water and Sewer Service Accessibility Review Mechanical Review Energy Conservation Compliance Jew Building Type Compliance Building Code Fire Compliance Review Miscellaneous Review Action Act ions Required for A�pro�al RO Box 280 19 E. Main St. Rexburg, Idaho 8344 Phone (208) 3593020 Fax (2L}8) 359-3022 Water fines are required to tested and 12/0912005 inspected before capering. All water lines are to be sized and installed according to the Uniform Plumbing Code. Roof drains and overflows are required to be 12/0-9/2pQ5 tested and inspected before covering. AIS roof drains are to be sized according to the Uniform Plumbing Code. Drains are required to be tested and inspected 12/09/2005: before covering. Site plan has been reviewed. 01/10/2006 Meet the requirements of the 2003 International 01/10/20uo Building Code (113C). The height and area meet the requirements of 61/10/2006 the 113C. All interior finishes must meet the requirements 0111012 UO of chapter 8 of the IBC. Water and sewer services are required to 01/� �12��6 tested and inspected before covering. Identify handicap parking spaces (with dimensions)on the site P12n. Building is Type 1113. A ia s Must meet the requirements of IBC Section 6p3. 1. Make the necessary changes to plans. Materials must meet the requirements of IBC Section 603. Fire retardant treated lumber is allowed in those uses indicated by IBC Section 603. 1. Identify the type of material used to construct the tower floor. ASI pages of the plans must be stamped by a