HomeMy WebLinkAboutJOIST - 05-00439 - 1272 Pleasant View - New SFRIMPORTANT
PLEASE RE
ATTACHES
TAKING PO
LAYOUT!
READ BY IP
DATE
A complete TJ-Xpert framing plan requires the Trus Joist Framer's Pccl--` ^ 'r
See Trus Joist Framer's Pocket Guide for Product Trademark Information
0500439
1272 Pleasant View
CJJAXPert
HANGER LIST - Simpson Strong -Tie Company, Inc.®
Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes
H1 20 IUT11 10-NIO 2-N10 (5)(6)
H2 5IUT11 10-NIO 2-N10 (5)
Hanqer Notes:
(5) Backer Blocks Required
(6) Filler Blocks Required
C (� [4 CE
Nov o z zuu5
JOIST AND BEAM LIST
Plot ID Length Product
A30
30'
117/8" TJI 110.1oist
A28
28'
117/8" TJI 110,1oist
A20
20'
117/8" TJI 110.1oist
A18
18'
It 7/8" TJI 110.1oist
Al2
12'
117/8" TTI 110.loist
A6
6'
117/8" TJI 110,loist
A2
2'
117/8" TJI 110.1oist
B12
12'
117/8" TJI 110 Joist
JOB COMMENTS
36-Jav Taylor Hdl 10'
Brian Haney Spec Hd2 18'
CREATED BY
HEADER LIST
13/4" x 9 1/2" 1.9E Microllam LVL
1 3/4" x 16" 19E Microllam LVL
ACCESSORIES LIST
Plies Qty
1 14
1 33
1 3
1 8
1 1
1 1
1 8
2 2
2 2
2 2
BMC West
BblV
or
5/8" or 3/4" Backer Blocks
1 30
1425 N Holmes Ave
F61
12' 2x6 Blocks
1 I.
Idaho Falls, ID 83401
Rm1
16' 11/4" x 11 7/8" 1.3E TimberStrand LSL
1 15
(208)557-5056
Sh1
4' x 6' 23/32" Panels (24" Span Rating)
1 63
FAX: (208)529-3610
Rm, Rim Board
LEVEL NOTES
File Name: 36 -Jay Taylor Brian Haney Spec -JOB
Level Name: Main Level
Platted: 10/31/2005 10:01
Desiqn Status:
Main Level ... 10/31/2005 09:57
Roof......... 10/31/2005 09:54
NOTE: Level desiqn times indicated above provide
assurance for proper level stacking.
Design Methodology: ASD
Floor Area Loadinq Is:
40psf Live Load and 15 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Ratinq Information:
Weiqhted Average: 47
Lowest Ratinq: 33
Hiqhest Ratinq: 65
Glued d Nailed Deckinq is Required
Direct Applied Celina is Not Required
Floor Decking: 23/32" Panels (24" Span Rating)
Normal O.C. Spacing = 16"*
"Unless noted otherwise
Scale: 1/8" = 1'
SYMBOL LEGEND
O Point Load
Line Load
Area Load
O Detail Callout Label
(See Framer's Pocket Guide)
Hd-t Header, and -t indicates quantity of 2x_
trimmers required at ends