Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS - 21-00442 - 1093 Arctic Willow Dr - Solar Panels
CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT PROJECT INFORMATION, VICINITY MAP www.bigdogenergy.com P V - 1 6/10/2021 MSPSUBACDCSLCMINVJBCBFMC M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X F L E X I B L E M E T A L L I C C O N D U I T ( E ) ( N ) E X T I N T E M T R M T V O C V M P I S C N T S E X I S T I N G N E W E X T E R I O R I N T E R I O R E L E C T R I C A L M E T A L L I C T U B I N G R I G I D M E T A L L I C T U B I N G V O L T A G E O P E N C I R C U I T V O L T A G E A T M A X . P O W E R S H O R T C I R C U I T C U R R E N T N O T T O S C A L E I M P C U R R E N T A T M A X . P O W E R A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C 2 0 1 8 C O D E P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E ADDITIONAL NOTES P L A N S E T L E G E N D A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N V I C I N I T Y M A P A P P L I C A B L E C O D E S S H E E T I N D E X 1 0 X 3 7 5 W J I N K O P H O T O V O L T A I C M O D U L E S 1 X 7 6 0 0 W G E N E R A C S Y S T E M S I Z E : 3 . 7 5 k W D C S T C A R R A Y A R E A : 1 7 0 S F K E L L Y T H O M P S O N 1 0 9 3 A R C T I C W I L L O W D R R E X B U R G , I D 8 3 4 4 0 2 0 8 - 3 5 1 - 1 6 9 6 KELLY THOMPSON 1093 ARCTIC WILLOW DR REXBURG, ID 83440 208-351-1696 Big Dog Renewable Electric Energy Contractor Lic # 017916 ELEC LIC: 8604760-5501 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ ALL CONDUIT TO RUN ON EXTERIOROF HOUSE UNLESS OTHERWISE NOTEDOCCUPANCY: R-3CONSTRUCTION TYPE: VBUNSPRINKLERED1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9. THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER. N ACINVSUBBATT MTR MSPSUBBLINVRSAC105' TRENCH WITHIN 3' M O R E T H A N 3 ' CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SITE PLAN, AERIAL VIEW www.bigdogenergy.com P V - 2 SITE PLAN A E R I A L V I E W S C A L E : N T S S C A L E : 1 " = 3 0 ' - 0 " TOTAL # OF PANELS24 EXISTING A B B R E V I A T I O N S I N V M S P A C I N V E R T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T M T R M E T E R Big Dog Renewable Electric Energy Contractor Lic # 017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 6/10/2021 KELLY THOMPSON 1093 ARCTIC WILLOW DR REXBURG, ID 83440 208-351-1696 S U B S U B P A N E L TOTAL # OF PANELS10 NEW B A T T B A T T E R Y B L B A C K U P L O A D S R S R A P I D S H U T D O W N ELECTRICAL EQUIPME N T C A L L O U T S 7.6kW INVERTER UNGROU N D E D GENERAC PWRCELL APKE 0 0 0 1 4 (240V) INVERTER240VAC, 32A, NEMA 3R, UL L I S T E D , (W/ INTEGRATED DC DISC O N N E C T ) WITH INTEGRATED GFP, W / I N T E G R A T E D A F P AC DISCONNECT SQUARE D # H 2 2 2 N R B 240VAC, 60A F USED NEMA 3 R , U L L I S T E D WITH 40A FUSES.200A MAIN SERVICE PANE L (W/ BIDIRECTIONAL UTILIT Y M E T E R ) GENERAC PV LINK OPTIMI Z E R SOLADECK MODEL 0783-41 J U N C T I O N BOX/ROOF PENETRATION, 6 0 0 V GENERAC PWRCELL 4 BAT T E R Y 2 . 8 6 K W E A C H 100A SUB PANEL AT SHOP F E E D I N G S H O P L O A D S SNAP RS INLINE DISCONN E C T S W I T C H RAPID SHUTDOWN SWITC H P 3 0 0 S O L A R E D G E O P T I M I Z E R 2 0 0 A E X I S T I N G S U B P A N E L A T H O U S E F E E D I N G L O A D S 7 . 6 k W I N V E R T E R U N G R O U N D E D S O L A R E D G E S E 7 6 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 2 4 0 V A C , 3 2 A , N E M A 3 R , U L L I S T E D , ( W / I N T E G R A T E D D C D I S C O N N E C T ) W I T H I N T E G R A T E D G F P , W / I N T E G R A T E D A F P 1 0 0 A B R E A K E R P A N E L F O R B A C K U P L O A D S B 3,750 W TOTAL SOLAR ARRAY NEW7,200 W TOTAL SOLAR ARRAY EXISTING24 SILFAB 300W MODULES EXISTING10 JINKO 375W NEWARRAY 12 STRINGS OF 5 MODULES @ INVERTER GENERAC 7.6KW2 STRINGS OF 12 MODULES @ INVERTER SOLAREDGE 7.6EXISTINGC ADWIRE AND CONDUIT CALLOUTS(2) #10 AWG PV/RHW-2(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1)#10 AWG THWN-2 IN 34" EMT/FMC(2)#8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT(2)#14 AWG THWN-2(1)#14 AWG THWN-2 GND IN 34" PVC(3)#8 AWG THWN-2(1)#10 AWG THWN-2 GND IN 34" EMT/1 14" PVC(3)#6 AWG THWN-2(1)#10 AWG THWN-2 GND IN 34" EMT(3)#10 AWG THWN-2 IN 34 FMC(3)#3/0 AWG THWN-2(1)#6 AWG THWN-2 GND IN PVC EXISTING(3)#4 AWG THWN-2(1)#8 AWG THWN-2 GND IN PVC EXISTING 123E A 3 0 A 3 0 A 3 0 A G E N E R A C P O W E R C O R E HII 4 4SEE PAGE 3 & 9 OF MANUALFOR COMPLIANCE WITHNEC 690.12MPPT 1MPPT 3 _~LMPPT 2 1 2 M O D U L E S I N S E R I E S 1 S T R I N G 1 T I L T : 2 8 ° A Z I M U T H : 1 8 0 ° J O N E P E R P A N E L J K L 2 S T R I N G S 1 - 2 T I L T : 2 8 ° A Z I M U T H : 1 9 2 ° / 2 8 2 ° / 1 0 2 ° E 5 M O D U L E S I N S E R I E S 5 M O D U L E S I N S E R I E S D D H H O N E P E R P A N E L O N E P E R P A N E L 1 1 1 1 2 2 E 5 M O D U L E : J I N K O 3 7 5 W V o c = 4 4 . 1 2 V I s c = 1 1 . 0 1 A V m p = 3 6 . 8 V I m p = 1 0 . 1 9 A A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . 3 NNG CJNGNNGL1L2L1L23BNGNNGL1L155L2L2LABEL TO SAYMANUAL DISCONNECT FORPARALLEL GENERATION 1 OF 2 LABEL TO SAYMANUAL DISCONNECT FORPARALLEL GENERATION 2 OF 2NNGM 5 0 A 6 NO L O A D S OV E R 4 0 A P W R C E L L B A T T E R Y 7 F 3 0 A 67 FGNNG200A200A80ANNG100A 1 2 M O D U L E S I N S E R I E S 1 S T R I N G 2 T I L T : 2 8 ° A Z I M U T H : 1 8 0 ° J O N E P E R P A N E L 2 40A 26.TAP 29. M O D U L E : S I L F A B 3 0 0 W V o c = 3 9 . 8 5 V I s c = 9 . 7 1 A V m p = 3 2 . 8 V I m p = 9 . 1 6 A A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . G K M WITHIN 3'89 89MORE THAN 3'ELECTRICAL SINGLE LINE DIAGRAM CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SINGLE LINE DIAGRAM www.bigdogenergy.com P V - 3 S C A L E : N T S E L E C T R I C A L N O T E S R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 2021-6-10 KELLY THOMPSON 1093 ARCTIC WILLOW DR REXBURG, ID 83440 208-351-1696 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) SCALE: JOB NO.: CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT REQUIRED SIGNAGE www.bigdogenergy.com P V - 4 REQUIRED SIGNAGE 6/10/2021 KELLY THOMPSON 1093 ARCTIC WILLOW DR REXBURG, ID 83440 208-351-1696 Big Dog Renewable Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 14" HIGHLETTERING PER NEC 690-17.2. LABEL FOR SOLAR AC DISCONNECT:FIRE DEPARTMENT REQUIRED SIGNAGE3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 38" HIGHLETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS,WHITE ON RED BACKGROUND AND A REFLECTIVE, WEATHERRESISTANT MATERIAL.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING:WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALS ON BOTHTHE LINE AND LOAD SIDES MAY BE ENERGIZED INTHE OPEN POSITION."SOLAR AC DISCONNECT"WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEMTHE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:CUSTOMER OWNEDONSITE POWER GENERATIONSYSTEM DISCONNECT5. LABEL INSTALLATION AT INTERCONNECT BREAKER:WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) 6. REFLE C T I V E P L A C A R D A T S E R V I C E S T A T I N G : 7. AT PV D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 8. THE F O L L O W I N G S I G N M U S T B E P R O V I D E D ON THE O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E PANELB O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : 9 SIGNA G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 10 SIGN A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M T O T A L R A T E D A C A M P S : 4 0 A / 4 0 A S Y S T E M A C V O L T A G E : 2 4 0 V DI R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M D C V O L T A G E : 2 4 0 V M A X D C C I R C U I T C U R R E N T : 3 2 A / 3 2 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A SCALE: JOB NO.: • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Best-selling panel globally for last 4 years • Top performance in the strictest 3rd party labs • 99.9% on-time delivery to the installer • Premium solar panel factories in USA and Malaysia EAGLE 66TR G4 370-390 WATT TILING RIBBON MONO MODULE Positive power tolerance of 0~+3% KEY FEATURES BUILDING YOUR TRUST IN SOLAR. JINKOSOLAR.US SOLAR BRAND THE MOST DEPENDABLE TR Technology Tiling Ribbon eliminates cell gaps to increase module efficiency and power. 9BB Half Cell Technology Uniquely designed 9 busbar mono half cut solar cells deliver ultra-high power in a small footprint. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Designed for Long Life Uses the same DuPont protective film as the Space Station, Mars Lander, and jetliners. Leading Warranty 12-year product and 25-year linear power warranty; 98% guaranteed first year, max 0.55% annual loss. 25 7.6kW 1Ø, 11.4kW 3Ø PWRcell Inverter with CTs Model: APKE00014, APKE00013Certification Model Reference: X7602, X11402 Solar + storage is simple with the Generac PWRcell™ Inverter. This bi-directional, REbus™-powered inverter offers a simple, efficient design for integrating smart batteries with solar. Ideal for self- supply, backup power, zero-export and energy cost management, the PWRcell Inverter is the industry’s most feature-rich line of inverters, available in single-phase and three-phase models. FEATURES & BENEFITS • Single inverter for grid-tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User-selectable modes for backup power, self-supply, time-of-use and zero-export • Free system monitoring included via PWRview™ Web Portal and Mobile App AC OUTPUT/GRID-TIE MODEL APKE00014 MODEL APKE00013 RATED AC POWER OUTPUT:7600W 11400W AC OUTPUT VOLTAGE:120/240, 1Ø VAC 120/208, 3Ø VAC AC FREQUENCY:60 Hz 60 Hz MAXIMUM CONTINUOUS OUTPUT CURRENT:32 A, RMS 32 A, RMS GROUND-FAULT ISOLATION DETECTION:Included Included CHARGE BATTERY FROM AC:Yes Yes THD (CURRENT):< 2%< 2% TYPICAL NIGHTTIME POWER CONSUMPTION:< 7W < 7W AC OUTPUT/BACKUP MODEL APKE00014 MODEL APKE00013 RATED AC BACKUP POWER OUTPUT (ISLANDED):8000W 8000W MAXIMUM AC BACKUP POWER OUTPUT:10000W 10000W AC BACKUP OUTPUT VOLTAGE:120/240, 1Ø VAC 120/240, 1Ø VAC AC FREQUENCY:60 Hz 60 Hz AC CIRCUIT BREAKER:50 A 50 A THD (VOLTAGE):< 2%< 2% AUTOMATIC SWITCHOVER TIME:< 1 Seconds < 1 Seconds TYPICAL NIGHTTIME POWER CONSUMPTION:30W 30W DC INPUT MODEL APKE00014 MODEL APKE00013 DC INPUT VOLTAGE RANGE:360-420 VDC 360-420 VDC NOMINAL DC BUS VOLTAGE:380 VDC 380 VDC MAX IMPORT CURRENT1:20 A 30 A MAX INPUT CURRENT2:30 A 30 A REVERSE-POLARITY PROTECTION:Yes Yes GROUND-FAULT ISOLATION DETECTION:Yes Yes TRANSFORMERLESS, UNGROUNDED:Yes Yes TYPICAL NIGHTTIME POWER CONSUMPTION:< 7W < 7W DC INPUT/ BATTERY MODEL APKE00014 MODEL APKE00013 MAXIMUM CONTINUOUS POWER:8000W 8000W INTERNAL DC DISTRIBUTION BREAKERS:4x 2p30A 4x 2p30A DC FUSES ON PLUS AND MINUS:40 A 40 A 2-POLE DISCONNECTION:Yes Yes EFFICIENCY MODEL APKE00014 MODEL APKE00013 PEAK EFFICIENCY:97%98% CEC WEIGHTED EFFICIENCY:96.50%97.50% 1Inverter limits DC current import to AC power rating. Total DC current from multiple DC inputs may safely exceed this value up to Max. Input Current. The inverter safely limits the amount utilized 2Per input, four DC inputs total Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528185 REV C ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. 33Ø inverters offer islanding for 1Ø loads 4Modbus 5Reduced power at extreme temperatures FEATURES AND MODES ISLANDING3:Yes GRID SELL:Yes SELF CONSUMPTION:Yes PRIORITIZED CHARGING FROM RENEWABLES:Yes GRID SUPPORT - ZERO EXPORT:Yes ADDITIONAL FEATURES SUPPORTED COMMUNICATION INTERFACES:REbus™, CANbus, RS4854, Ethernet SYSTEM MONITORING:PWRview™ Web Portal and Mobile App BACKUP LOADS DISCONNECT3:Yes MANUAL INVERTER BYPASS SWITCH:Automatic WARRANTY:10 Years DIMENSIONS AND INSTALLATION SPECIFICATIONS ENCLOSURE KNOCKOUTS - QTY, SIZE - IN (MM):6 x Combo 3/4" x 1" (19 x 25.4) 7 x Combo 1/2" x 3/4" (12.7 x 19) DIMENSIONS L x W x H - IN (MM):24.5" x 19.25" x 8" (622.3 x 488.9 x 203.2) WEIGHT - LB (KG):62.7 (28.4) COOLING:Forced convection NOISE:< 40 dBA OPERATING TEMPERATURE - FAHRENHEIT (CELSIUS):-4 to 122 °F (-20 to 50 °C)5 PROTECTION RATING:NEMA 3R STANDARDS COMPLIANCE SAFETY:UL1741 SA, CSA 22.2 GRID CONNECTION STANDARDS:IEEE1547, Rule 21, Rule 14H, CSIP EMISSIONS:FCC Part 15 Class B INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED:PWRcell™ Battery MODULE STRING SIZE PER PV LINK OPTIMIZER:Varies, refer to PV Link Installation Manual MAXIMUM RECOMMENDED DC POWER FROM PV:15kW 2500W MPPT Substring Optimizer Model: APKE00010Certification Model Reference: S2502 PV Link is the simple solar optimizer for quick installation and long-lasting performance. Connect PV modules to each PV Link to overcome shading and challenging roof lines. FEATURES & BENEFITS • Fast, simple installation • Lower failure risk than module-level optimizers • 2017/2020 NEC rapid shutdown compliant with SnapRS™ • Quick connections with MC4 connectors • Exports up to 2500W • Compatible with PWRcell™ Inverters • Cost-effective solution for high-performance PV • Ground-fault protection PV Link™ SINGLE-STRING PV ARRAY WITH SnapRS DEVICES Where PV module-level rapid shutdown is required (NEC 690.12), a SnapRS device (RS) is installed to negative (-) lead of each PV module. Diagram is applicable for most 60 cell PV modules. Modules with higher cell count may require a different arrangement. Contact Generac for more details. RS RSRSRS RSRSRS RS PWRcellInverter PV Link Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528162 REV C ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. PV Link™ (APKE00010) RATED POWER*:2500W PEAK EFFICIENCY:99% MPPT VOLTAGE RANGE:60-360 VMP MAX INPUT VOLTAGE:420 VOC; max when cold MAX OUTPUT:420 VOC NOMINAL OUTPUT (REbus™):380 VDC MAX OUTPUT CURRENT (CONTINUOUS):8 A MAX OUTPUT CURRENT (FAULT):10 A MAX INPUT CURRENT (CONTINUOUS):13 A @ 50°C, 10 A @ 70°C MAX INPUT SHORT CIRCUIT CURRENT (ISC):18 A STANDBY POWER:< 1 W PROTECTIONS: Ground-fault, Arc-fault (Arc-fault Type 1 AFCI, Integrated), PVRSE MAX OPERATING TEMP: FAHRENHEIT (CELSIUS)158 ºF (70 ºC) SYSTEM MONITORING:PWRview™ Web Portal and Mobile App ENCLOSURE:Type 3R WEIGHT - LB (KG):7.3 lb (3.3 kg) DIMENSIONS, L x W x H - IN (MM):15.4" x 2" x 9.6" (391.2 x 50.8 x 243.8) COMPLIANCE:UL 1741, CSA 22.2 WARRANTY:25 Years *PV Link can tolerate higher than rated power at its input if Max Input Voltage and Short Circuit Current specifications are not exceeded Model APKE00007, PWRcell Battery Cabinet Model A0000391219, 2.85kWh PWRcell Battery ModuleModel APKE00008, PWRcell Spacer KitModel APKE00009, PWRcell Upgrade Kit FEATURES & BENEFITS • Connect up to 2 PWRcell Battery Cabinets to a single PWRcell Inverter for up to 34.2kWh of storage • Best-in-class battery backup power • Plug-and-play with PWRcell Inverter and PV Link™ • Time-of-use (TOU) and zero-export ready • Residential and commercial application ready BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY PWRcellBattery Cabinet PWRcell 1717.1kWh 6x Battery Module PWRcell 1514.3kWh 5x Battery Module+ Module Spacer Kit PWRcell 1211.4kWh 4x Battery Module PWRcell 98.6kWh 3x Battery Module+ Module Spacer Kit OR OR OR SPACER SPACER PWRcellBattery CabinetBack PanelModuleSpacer Kitx1 BatteryModulex5PWRcellBattery CabinetFront Panel The PWRcell™ Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need, small or large. No other smart battery offers the power and flexibility of PWRcell. Whether for backup power or smart energy management, PWRcell has power and capacity options for every need, without sacrificing flexibility or function. PWRcell BATTERY CABINET DESIGN The PWRcell Battery Cabinet allows system owners the flexibility to scale from the economical 8.6kWh PWRcell 9 to the massive 17.1kWh PWRcell 17 by installing additional battery modules to the PWRcell Battery Cabinet. When needs change, an existing PWRcell Battery Cabinet can be upgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration. Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528139 REV B ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. UPGRADING PWRcell Inside of the PWRcell Battery Cabinet, battery modules are stacked two deep on three levels, allowing for up to six modules to be connected in series. You can upgrade an existing PWRcell Battery Cabinet by adding Battery Modules and a Module Spacer (APKE00008) if required. PWRcell 9 and PWRcell 15 require a module spacer. Generac offers a convenient PWRcell Battery Upgrade Kit (APKE00009) to help replace lost or misplaced hardware. A PWRcell Battery Upgrade Kit may be purchased from your Generac distributor. Refer to the table to the right for material requirements related to upgrading the PWRcell Battery Cabinet. UPGRADE MATERIAL REQUIREMENTS ENDING CONFIGURATION ST A R T I N G C O N F I G U R A T I O N PWRcell 17 PWRcell 15 PWRcell 12 PWRcell 9 + 3 x PWRCell Mod+ 2 x APKE00009*+ 2 x PWRCell Mod+ 1 x APKE00009*+ 1 x PWRCell Mod+ 1 x APKE00009* PWRcell 12 + 2 x PWRCell Mod+ 1 x APKE00009*+ 1 x PWRCell Mod+ 1 x APKE00008 PWRcell 15 + 1 x PWRCell Mod+ 1 x APKE00009* *APKE00009 (Upgrade kit) only required if original hardware is unavailable PWRcell™ BATTERY CONFIGURATIONS 9 12 15 17 BATTERY MODULES:3 4 5 6 USABLE ENERGY:8.6kWh 11.4kWh 14.3kWh 17.1kWh POWER - RATED CONTINUOUS: 3.4kW 4.5kW 5.6kW 6.7kW POWER - 60 MINUTES:4.2kW 5.6kW 7.0kW 8.4kW POWER - 2 MINUTES:5.0kW 6.7kW 8.4kW 10.0kW REbus™ VOLTAGE - INPUT/OUTPUT:360-420 VDC MODULE VOLTAGE:46.8 VDC ROUND-TRIP EFFICIENCY:96.50% OPERATING TEMPERATURE - FAHRENHEIT (CELSIUS):41 to 113 °F (5 to 45 °C) RECOMMENDED AMBIENT TEMPERATURE - FAHRENHEIT (CELSIUS): 55 to 86 °F (13 to 30 ºC) MAXIMUM INSTALLATION ALTITUDE - FT (M):9834 (3000) DIMENSIONS, L x W x H - IN (MM):22" x 10" x 68" (559 x 254 x 1727) WEIGHT, ENCLOSURE - LB (KG):115 (52) WEIGHT, INSTALLED - LB (KG):280 (127)335 (152)390 (178)445 (202) WARRANTY - LI-ION MODULES:10 Years, (22.6 MWh)10 Years, (30.2 MWh)10 Years, (37.8 MWh) 10 Years, (45.3 MWh) WARRANTY - ELECTRONICS AND ENCLOSURE:10 Years COMMUNICATION PROTOCOL:REbus™ DC Nanogrid™ COMPLIANCE:UL 9540, UL 1973, UL 1642, CSA 22.2 MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL