RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Building Permit Number: as- e�106
Project:
'
/ate Job Address: GL/ ,4Aym
q
Zoning:
Z4�
Number of Stories: _� Basement: es No
/ Fin. nlin. Fixtures: Z�r-
Floor Area (sf): /%57) finished, /g$D unfinished, %S . garage
Valuation: $ Permit Fee: $ Plan Check Fee: $
The following comments based on the 2003 edition of the Intemational Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
specifications does not permit the violation of any section of the Intemational Residential Code or any federal,
state or local regulations.
PLAN CHECK
Alans
_To Scale Zgible
ZPlot Plan Y / Flood Plain
/Floor / Foundation Plan
Section showing construction details
All Building Elevations
Design Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
/Suss Calculation Sheets & //Floor Joist Details
Mechanical Design
Znergy Calculations (R320 & Ch 11)
B. Zoning (check one - in some cases LDR2 and MDR may apply)
_el LDR LDRI _Lot area —LDR- 12,000 sq. ft. min. (width 80 ft. min) & LDR1- 8,000 sq. ft. min
(width60 ft. min.).(LDRl duplex - 10,000 sq. ft. min.)
C. �Se
/Single Family _Duplex (LDR1 only - Conditional use permit?)
D. §et Backs (taken from eaves)
Front set back (32 ft. from curb) _Note: 60% min of front yard green
/Rear set back (LDR 25 ft. & LDRI 20 ft.)
Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
/uilding-Height (maximum 30 ft.)
E. /Footings
_Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing)
,4ebar (244 continuous)
oting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab —interior)
2FFndation
Foundation walls w/ rebar (city ordinance)
_X/1/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1
Foundation Drainage (foundations on sift soil shall be designed per R405)
!Damp proofing/Waterproofing to finish grade. R406.1(fad. extends 6" min above grade R404.1.6)
--Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
'Crawl Space Ventilation/Insulation =1 sf vent per 150 sf. (with moisture barrier 1 sf. per 1500 sq. ft.) and
within 3' of each corner (insulate walls vent to inside of home) R408.2
/rading slope away from house. R401.3
GG Fr me
7eismic Hold Downs and Braced Wall Panels (R602.10)
_Floors joists sized as per R502.3, Wood I joists sized per manufr.
_Joists Under Load Bearing Partitions shall be doubled. R502.4
_Girders sized per R502.5 or per manufr. Tables for engineered products
_Cantilevers (comply with R502.3.3 or manufr instruction)
✓ Floor Sheathing (3/4" min for joists 24" oc & 5/8" for joists 16" oc) R503.1
'Zwall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3
/Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7
Roof Trusses (desigped according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
'after and Truss tie -downs. (R802.10.5)
Zttic Access 22" x 30" min. opening (R807)
H. Exterior Covering
_Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1
7I. R of Covering and Ventilation
Roof Ventilation as per R806
Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905._)
I Firewalls
Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire -rated door) R309.1
`Two Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1
---Twin homes & Townhouses (2 hr separation & 4' overbum protection or parapet) R317.2
_One hr walls parallel to and within 3 ft of property line w/ NO openings. R302
—Penetrations in previous 3 items to comply with R317.3
K G eral Requirements
use Numbers R321
_/H f Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3
/Interior and exterior stair illumination shall comply with R303.6.
/Bathroom Fixture clearances comply with Figure R307.2
_/ne room at least 120 sf.; /ther habitable rooms 70 sf min w/ a min. dimension of 7 ft. R304
*areas w/sloped ceilings less than 5 ft in height & furred ceilings less than 7ft DO NOT comply
*50916 or more of the required area must be at least 7ft high in rooms w/sloped ceiling
u
Egress clearance from window wells under cantilevered floors. R310.2
Glazing at Hazardous Locations R308
�mergency Egress in all sleeping rooms and basements with habitable space R310
_ZOne required Exit Door shall comply with R311.4
Zandings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3
/__,Stair Rise / Run (7 3/4" max. rise & 10" min.�read, nosing req'd if <11") Stair Width (36" min),
�tairway Headroom (6' 8" min.) _Handrails (34"to 38" above stair nosing)(R311.5)
Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.5.8
Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2
Guardrails complying with R312 _,,�andrails complying with R311.5.6
//Smoke Alarms (each bedroom and common area and one on each level (R 313)
L. Energy
_Homes with glazing < 15% of gross area of ext. walls (Townhouses < 25%) to comply w/ Chapter 11.
*Otherwise shall meet requirements ofIECC for respective building type. N1101.2
Vapor retarder on warm in winter side of walls, ceiling and floors R318
Water Heater heat traps IECC 504.7
;� Duct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3
_Plans match quantities & values on a "passing" REScheck compliance report
M. Mechanical
/as appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2
_Room access 24" min width/Attic access clear opening 20x30iUnder floor r.o. 2200. M1305
—Potential vent/connector offset > 75% of total height (Exception provided by G2428) G2427.6.4
Drryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3
Gas "point of delivery" and material used to determine pipe sizing. G2413
Zone:
Surrounding Land Uses:
Elevations submitted:
Landscape Plan submitted:
Lighting Plan submitted:
Site Plan Review Checklist
Project: . C MnZ —
Permit# n to 00, �Tl
Ppuire P.idW Fpp M?
Use Consistent with zoning designation 11` \ 0 c C
Compliance with Comprehensive Plan
Flood Plain Check
Plans are to scale l�6f
North arrow W V)
Building Coverage
Building setbacks:
Front yard - W o!&Ccc ' -
Side yard
Back yard
VAo
V\v
Building Height
ICI
Minimum distance between buildings
Clear site tirangle
Driveway, parking lot dimensions
Parking space# AA u, WY Sav\uS
�Z
Parking space sizes
Parking isle widths
Handicapped requirements
Unloading, loading area
Parking spaces located in close proximity to buildings
Sidwalks along right of way
Internal pedestrian walkways
Snow storage
Open/common spaces functional?
Fencing/screening (HVAC equipment, dumpsters, parking, etc.)
Trash dumpster shown and screened
Buffering/landscaping requirements
Lighting
Design standards
Committee Meeting Held If needed
i
rn
REScheck Compliance Certificate
2003 IECC
REScheck So$ware Version 3.6 Release la
Data filename: C:1Program FileslChecklRESchecklBasic.rck
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.19
DATE: 11/16/05
COMPLIANCE: Passes
Maximum UA = 446
Your Home LTA = 395 - -
11.4% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low-E
Door 1: Solid
Door 2: Glass
Basement Wall 1: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Window 2: Vinyl Frame:Double Pane with Low-E
Furnace 1: Forced Hot Air, 92 AFUE
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter -Val e R-Value UmFactor UA
1950 38.0 0.0
59
2296 22.0 0.0
104
364
0.350 127
40
0.350 14
36
0.350 13
1088 11.6 0.0
67
32
0.350 11
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release la (fDrmerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date