Loading...
HomeMy WebLinkAboutLIGHTING APPLICATION - 05-00380 - Rexburg Surgical Center`r "1W Lighting Application Worksheet 2001 1ECC CC)Mrheck--F,7 SofRvare Version 3.0 Release2b 0500380 Center Section l: Allowed Ughting PowerCalculatiol Surgical A R C n D l� IJ Total Floor Allowed Allowed 0cT - 5 Arun Watts Watts Building T e 02 watts/112 Medical and Clinical Cat By 11506 1.6 18410 'f otal Allowed Watts = 18410 Section 2: Actual Ughting Power Calculation A R C D F F Fixture Fixture Description / Lamps/ 4 of Fixture M Lamp Description ! Wattage Per Lamn / Bally Fixture Fixtures W art. fD x Et F 1 2 lamp Quor, wrap / 48" TR 32W / Elecmmnic 2 13 61 793 F2 3 lamp fluor. rural / 49" Tit 32W / Electmnic 3 5 95 475 F3 2 lamp open strip fluor. / 48" T8 32W / Electronic 2 14 61 854 FS 2 lamp lay -in troller / 48" T8 32W / Electronic 2 11 61 671 F6 3 lamp lay -in troller / 48" TR 32W / Electronic 3 4 95 380 F7 4 lamp lay -in tmlfer / 49" TR 32W / Electronic 4 9 1 l2 100R F8 2 lamp over minor fluor. / 48" T8 32W / Electronic 2 1 61 61 F9 2 lamp recessed fluor. / 48" T8 32W / Electronic 2 38 61 2318 F 10 3 lamp recessed fluor. / 48" T8 32W / Elec-tronic 3 9 95 855 F11 recessed can / Triple 4-pin 26W Electronic 1 8 26 208 F14 wall sconce / Triple4-pin26W / Electronic 1 1 26 26 F16 6 lamp surgical fluor. / 48" TS 32W / Electronic 6 32 173 5536 F 17 1 lamp under counter fluor. / 48" TR 32W / Electmnic 1 42 37 1554 F 18 recessed can (wet location) ! Triple 4-pin I RW / Electronic 1 I 18 18 F22 2 lamp recessed indirect fluor. / 48" T8 32W / Electrnic 2 47 61 2867 P25 1 lamp strip light / 48" T8 32W / Electronic 1 3 37 111 F26 nurse station comp. Hunt. / Quad 2-pin 22W / Electronic 1 2 22 44 Total Actual Watts = 17779 Section 3: Compliance Calculation ifthe Total Allowed IVatts minus the Total Actual Watts is greater they or equal to zero, the building complies. Total Allowed Watts = 18410 Total Actual Watts = 17779 Proiect Compliance = 631 Lighting PASSES: Design 3% better than code l' J [ ] I 7. Photocell/astronomical time switch on exterior lights. Exceptions: Areas requiring lighting during daylight Fours [ I R. Tandem► wired one -lamp and three -lamp ballwsted Iu111inaires. Exceptions: Electronic high-fiequency ballasts; Luminaires no[ on same switch P. Section 4: Compliance Statement The proposed lighting dcsign repru-i nted in this document is consistent with the building pltuis, spe6fications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2001. IEC;C, Chapter 8, requirements in -COMchcck--A7. Version 3.0 Release 2b and to comply with the mandatory requirements in the Requirements Checklist. Principal Lighting Designer -Name M Signature Dare r� Lagbting Compliance Certificate 2001 IFEC COMchech-F,?, Soiiwarre Version 3.0 Relertse 2b Data filename: Untitled.cck Section l: Project Information Project Name: Designer/Contractor: Document Author: Notes: Rexburg Surgical Center Payne Engineering I11e. Mike Payne August 30, 2005 Section 2: General [nformadon Building Use Description by: Whole Building Type Project Type: New Construction Pennit Number Checked By/Date Building Time Floor Are Medical and Clinical Care 11506 Section 3: Requirements Checklist Bldg. I Dent. Use 1 interior Lighting ! 1. Total actual watts must be less than oi- equal to total al ]owed watts I Allowed Watts Actual Watts Complies(Y/N) I 18410 17779 YES Exterior• Lighting ] 1 2. Efficacy greatet- than 45 lumens/W Exceptions- 1 Specialized lighting highlighting features ofliistoric buildings; si&mage; safrty or security lighting; 1 low -voltage landscape lighting. I Controls, Switching, and Wiring [ J I 3. Independent controls fir each space (.switch/occupancy sensor). ! Exception: Areas that must he continuously illuminated. 4. Master switch at entry to hotel/motel guest room. 1 4. Two switches or dimmer in each. space to provide unitbrin light reduction capability. I 1'xceptions: i Only one luminaire in space; An occupant -sensing device controls the M-ea; I The area is a corridor•, storcroom, restrootn, or lobby; :'1rms tliat must be continuously illuminated; t Areas greater than 250 scl, tt. j 6. Automatic lighting shuroff control in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.t.