Loading...
HomeMy WebLinkAboutSHORT FORM - 05-00418 - 1162 Crescent Dr - New SFR MechanicalShort Form ZONE1 KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Htg Clg Outside db (OF) -6 89 Method Inside db (OF) 68 75 Construction quality Design TD (OF) 74 14 Fireplaces Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -31 HEATING EQUIPMENT Make PAYNE HEATING & COOLING Trade Payne Model PG9MAA060100 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 100000 Btuh 93000 Btuh 87 OF 1160 cfm 0.031 cfm/Btuh 0.60 in H2O Job: SHAUN & DEANNA Date: AUGUST 12, 2005 By: Kelli Bakke Infiltration Simplified Average 0 COOLING EQUIPMENT Make Payne Trade Payne PA12 Cond PA12NA036-A Coil PFlMNA036 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 11.5 SEER 24360 Btuh 10440 Btuh 34800 Btuh 1160 cfm 0.075 cfm/Btuh 0.60 in H2O 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (Cfm) Bath 1 108 478 8 15 1 Bed 5 203 1896 146 59 11 Storage 2 133 0 0 0 0 Cold Stor 75 0 0 0 0 Storage 156 0 0 0 0 Bed 4 184 966 130 30 10 Mach 63 0 0 0 0 Family Room 1016 6568 1812 205 136 Garage Found 1389 0 0 0 0 M Bed 289 4237 1004 132 75 Bath 2 72 827 708 26 53 Bed 1 175 3023 643 94 48 Bed 2 136 1819 507 57 38 M Bath/Clo 211 1363 784 43 59 Office 156 2490 607 78 46 Laundry E A..J 1l 119 Q1 2597 LAA 944 'In 81 .1 71 Al Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:38 C:Mwumehts and SeB1ngMDra03IDesMoplSD.np Cale = MJ8 Orientation = N Page 3 !_ J tSain 3 zo / l u Uji4w LL 14I Pantry 53 0 0 0 0 Family/Kitchen 856 8215 6770 256 508 Garage 1330 0 0 0 0 Bed 3 162 1456 138 45 10 ZONE1 d 6977 37159 15455 1160 1160 Other equip loads 43057 8146 Equip. @ 0.94 RSM 22185 Latent cooling 0 T/1TA 1 Q &%n-s-7 ann4 � nn4 nr 4 4 nf% 4 4 Q/A I V I 4r9LV Vol f V VL IV LL 1 VJ 1 1 V V 1 1 V V Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 6.0.18 RSR40859 CADocuments and Settings\Dratt3\Desktop\SD.rrp Calc = MJ8 Orientation = N 2005-Aug-13 08:10:38 Page 4 Short Form Job: SHAUN&DEANNA Date: AUGUST 12, 2005 UPPER By: Kalil Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID NOTE: t] pperz F64 F✓(K1jhC6 j H+0UbA 0. ✓PP°✓ FIoJ. i�2 rAavlty • L-o At. + r 4« V^ S1.109014 T iltiw- 0 1+ GNAto Sef✓ ee tlao2• Design• • Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 68 75 Construction quality Average Design TD (°F) 74 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -31 HEATING EQUIPMENT COOLING EQUIPMENT Make PAYNE HEATING & COOLING Make Payne Trade Payne Trade Payne PA12 Model PG9MAA048060' Cond PA12NA024-B Coil CK5A/CK5BA024+TDR Efficiency 91.5 AFUE Efficiency 12 SEER Heating input 60000 Btuh Sensible cooling 16100 Btuh Heating output 56000 Btuh Latent cooling 6900 Btuh Temperature rise 79 OF Total cooling 23000 Btuh Actual air flow 767 cfm Actual air flow 767 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.073 cfm/Btuh Static pressure 0.55 in H2O Static pressure 0.55 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Fam 973 9286 4416 226 322 Office 2 152 1408 556 34 41 Family 2363 20775 5544 506 404 UPPER d 3488 31470 10516 767 767 Other equip loads 14059 2660 Equip. @ 0.94 RSM 12385 Latent cooling 0 T Al C I • A00 1 AEG• A•1f0� lCl 10-1 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:38 C: muments and Settings\Dra83\DesMepM.np Calc = Wit Orientation = N Page 2 Basement Job #: SHAUN & DEANNA Performed by Kelli Bakke for: SHAUN & DEANNA RESIDENCE MADISON COUNTY REXBURG, ID KENT & KENT HEATING CASCADE DRIVE IDAHO FALLS, IDAHO, 83401 Scale: 1 : 126 Page 1 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:11 C:IDocuments and Settings\Draft31D.. Main Floor Job #: SHAUN & DEANNA Performed by Kelli Bakke for: SHAUN & DEANNA RESIDENCE MADISON COUNTY REXBURG, ID KENT & KENT HEATING CASCADE DRIVE IDAHO FALLS, IDAHO, 83401 Scale: 1 : 126 Page 2 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:11 :\Documents and Settinas\Dr 3 Upper Floor Sv�pIY 12ef f ��ru I boe,+-to SGrv� UpPf-r T-Ico2. Job #: SHAUN & DEANNA Performed by Kelli Bakke for: SHAUN & DEANNA RESIDENCE MADISON COUNTY REXBURG, ID KENT & KENT HEATING CASCADE DRIVE IDAHO FALLS, IDAHO, 83401 Scale: 1 : 126 Page 3 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:11 iments and Settings\Dn j Right-J Multizone Summary Report. KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 ZONE NAME UPPER ZONE1 Entire House Heating Volume ACH AVF (f3) (cfm) 27906 0.30 139 22024 0.26 94 49930 0.28 233 HTM Volume (Stuh/f 2) (f 3) 3.9 27906 3.9 22024 3.9 49930 Load and AVF Summary Job: SHAUN & DEANNA Date: AUGUST 12, 2005 By: Kelli Bakke Cooling ACH AVF HTM (cfm) (Btuh/W) 0.16 74 0.4 0.14 50 0.4 0.15 125 0.4 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Fam 973 9286 4416 226 322 Office 2 152 1408 556 34 41 Family 2363 20775 5544 506 404 UPPER 3488 45529 10516 767 767 Bath 1 108 478 8 15 1 Bed 5 203 1896 146 59 11 Storage 2 133 0 0 0 0 Cold Stor 75 0 0 0 0 Storage 156 0 0 0 0 Bed 4 184 966 130 30 10 Mech 63 0 0 0 0 Family Room 1016 6568 1812 205 136 Garage Found 1389 0 0 0 0 M Bed 289 4237 1004 132 75 Bath 2 72 827 708 26 53 Bed 1 175 3023 643 94 48 Bed 2 136 1819 507 57 38 M Bath/Clo 211 1363 784 43 59 Office 156 2490 607 78 46 Laundry 119 2597 944 81 71 Mud Room 67 514 622 16 47 Bath 3 25 710 633 22 47 Pantry 53 0 0 0 0 Family/Kitchen 856 8215 6770 256 508 Garage 1330 0 0 0 0 Bed 3 162 1456 138 45 10 ZONE1 6977 80216 15455 1160 1160 Entire House 10465 68629 25971 767 767 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:38 C1Documents and Setings\Dm83\Desktop\SD.np Calc=MJS Orientation=N Pagel Building Analysis UPPER KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Indoor: Idaho Falls, ID, US Indoor temperature (OF) Elevation: 4741 ft Design TD (OF) Latitude: 440N Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/lb) Dry bulb (OF) -6 89 Infiltration: Daily range °F) - 34 (H ) Method Wet bulb (° ) - 60 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Component Btuh/ft2 Btuh % of load Walls 5.0 12164 26.7 Glazing 25.9 414 0.9 Doors 0.0 0 0.0 Ceilings 2.4 8260 18.1 Floors 0.8 1130 2.5 Infiltration 3.9 9501 20.9 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 14059 30.9 Adjustments 0 Total 45529 100.0 Component Btuh/Q2 Btuh % of load Walls 0.6 1545 11.7 Glazing 6.2 100 0.8 Doors 0.0 0 0.0 Ceilings 1.3 4688 35.6 Floors 0.0 0 0.0 Infiltration 0.4 963 7.3 Ducts 0 0.0 Ventilation 2660 20.2 Internal gains 3220 24.4 Blower 0 0.0 Adjustments 0 To at 13176 100.0 Overall U-value = 0.043 Btuh/ft? °F WARNING: window to floor area ratio = 0.5% - less than 5%. Job: SHAUN & DEANNA Date: AUGUST 12, 2005 By: Kalil Bakke Heattii8ng 74 50 57.0 Simplified Average 0 Cooling 14 50 -31.5 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:38 C:\Doaumenls and Seltings\Dra83\DesktopZD.np Calc = MJ8 Orientation= N Page 2 Building Analysis ", ZONE1 KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Indoor: Idaho Falls, ID US Indoor temperature (°F) Elevation: 4'7 l ft Design TD (°F) Latitude: 440N Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/lb) Dry bulb (°F) -6 89 Infiltration: Daily range�°F) - 34 (H) Method Wet bulb (° ) - 60 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Component Btuh/ft2 Btuh % of load Walls 2.9 17204 21.4 Glazing 25.9 9360 11.7 Doors 23.7 2265 2.8 Ceilings 2.4 139 0.2 Floors 0.5 1757 2.2 Infiltration 2.1 6434 8.0 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 43057 53.7 Adjustments 0 Total 80216 100.0 Component Btuh/ft2 Btuh % of load Walls 0.2 1054 4.5 Glazing 6.2 2251 9.5 Doors 0.0 0 0.0 Ceilings 1.3 79 0.3 Floors 0.0 0 0.0 Infiltration 0.2 652 2.8 Ducts 0 0.0 Ventilation 8146 34.5 Internal gains 11420 48.4 Blower 0 0.0 Adjustments 0 Total 1 1 23601 100.0 Overall U-value = 0.061 Btuh/ftl °F Data entries checked. Job: SHAUN & DEANNA Date: AUGUST 12, 2005 By: Kalil Bakke Heating Cooling 74 14 50 50 57.0 -31.5 Simplified Average 0 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08.10-.38 CMocumerds and Seft1rgs\Dmft3XDes;dopkSD.nrp Calc=MJ8 Orientation=N Page3 Com onent Constructions r/ Job: AUGUN 80 p Date: AUGUST 12,2005 2005 Entire House By: Kell[Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 Project• • For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 68 75 Elevation: 4741 ft Design TD (OF) 74 14 Latitude: 44ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 57.0 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily range (OF) - 34 (H) Method Simplified Wet bulb (OF) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain (W) tStuNR;'F) (fiMFlBtuh) (Btu".) (Bluh) (Btu",) (Btuh) Walls 12E-Osw: Wood stud frame, siding or stucco, no board insulation, n 1469 0.068 19.0 4.23 6213 0.54 789 R-19 cavity insulation a 894 0.068 19.0 2.59 2315 0.33 294 s 1545 0.068 19.0 3.60 5556 0.46 706 w 891 0.068 19.0 4.24 3771 0.54 479 all 4798 0.068 19.0 3.72 17855 0.47 2268 15B13-Owc-8: Basement - 8" concrete, wood framing, interior finish, n 807 0.049 13.0 2.35 1899 0.00 0 R-13 cavity, no board insulation, 8' a 482 0.049 13.0 0.40 191 0.00 1 s 887 0.049 13.0 2.01 1780 0.01 12 w 462 0.049 13.0 2.71 1249 0.01 6 all 2638 0.049 13.0 1.94 5119 0.01 20 Partitions 12C-Osw: Wood stud frame, siding or stucco, no board insulation, R-13 cavity insulation Windows 61A: Vinyl Frame: Double Pane, clear low-e Doors 71A: Metal door, paper honeycomb, with storm Ceilings 16B-30ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-30 insulation 950 0.091 13.0 6.73 6394 0.33 311 It 152 0.350 0.0 25.9 3947 4.90 747 n 80 0.350 0.0 25.9 2072 4.90 392 e 16 0.350 0.0 25.9 414 4.90 78 s 90 0.350 0.0 25.9 2331 4.90 441 IN 19 0.350 0.0 25.9 492 4.90 93 w 20 0.350 0.0 25.9 518 4.90 98 all 377 0.350 0.0 25.9 9775 4.90 1849 n 55 0.320 0.0 23.7 1298 0.00 0 s 41 0.320 0.0 23.7 967 0.00 0 all 96 0.320 0.0 23.7 2265 0.00 0 3547 0.032 30.0 2.37 8399 1.34 4767 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-1 3 08:10:39 C:\Dowmerds and SetIhgs\Drafi3\DesktopGSD.rrp Calc = MJ8 Orientation = N Page 1 Floors ���� t J 91A-B: Tile covered basement floor, No instiliion, 67' wide 4877 0.022 0. W 0.59 2887 0.00 Right -Suite Residential 6.0.18 RSR40859 CMccuments and SettingslDraft3XDesktoplSD.rrp Calc = MJ8 Orientation = N 2005-Aug-13 08:10:39 Page 2 SHA EANNA Component Constructions Job: AUGUN&D,2005 t' Date: AUGUST 12, 2005 UPPER By: Kell] Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 68 75 Elevation: 4741 ft Design TD (OF) 74 14 Latitude: 44ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 57.0 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily range (OF) - 34 (H) Method Simplified Wet bulb (OF) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value InsulR Htg HTM Loss CIg HTM Gain I8*) atuhdt'-'F) fllk-F/Bluh) atuNh•) (Bluh) (Bluhlfl') (Btuh) Walls 12E-Osw: Wood stud frame, siding or stucco, no board insulation, n 789 0.068 19.0 5.03 3969 0.64 504 R-19 cavity insulation a 412 0.068 19.0 5.03 2073 0.64 263 s 789 0.068 19.0 5.03 3969 0.64 504 w 428 0.068 19.0 5.03 2154 0.64 274 all 2417 0.068 19.0 5.03 12164 0.64 1545 Partitions (none) Windows 61 A: Vinyl Frame: Double Pane, clear low-e e Doors (none) Ceilings 16B-30ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-30 insulation Floors 91A-B: Tile covered basement floor, No insulation, 67' wide Right -Suite Residential 6.0.18 RSR40850 C:\Documents and Settings\Drak3\Desktop\SD.np Caic=MJ8 Odentation=N 16 0.350 0.0 3488 0.032 30.0 1389 0.022 0.0 25.9 414 4.90 78 2.37 8260 1.34 4688 0.81 1130 0.00 0 2005-Aug-13 08:10:39 Page 3 1"./ Job: SHAUN & DEANNA Component Constructions Date: AUGUST12,2005 ZONE1 By: Kelli Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN St DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 68 75 Elevation: 4741 ft Design TD (OF) 74 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 57.0 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily range (OF) - 34 (H) Method Simplified Wet bulb (OF) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value InsulR Htg HTM Loss CIg HTM Gain (W) (BtuhW---F) (fil-Fvaluh) (BIu"2) (Bluh) Stuw) (Btuh) Walls 12E-Osw: Wood stud frame, siding or stucco, no board insulation, In 680 0.068 19.0 3.30 2244 0.42 285 R-19 cavity insulation a 482 0.068 19.0 0.50 242 0.06 31 s 756 0.068 19.0 2.10 1587 0.27 202 w 463 0.068 19.0 3.50 1618 0.44 206 all 2380 0.068 19.0 2.39 5691 0.30 723 151313-Owc-8: Basement - 8" concrete, wood framing, interior finish, n 807 0.049 13.0 2.35 1899 0.00 0 R-13 cavity, no board insulation, 8' a 482 0.049 13.0 0.40 191 0.00 1 s 887 0.049 13.0 2.01 1780 0.01 12 w 462 0.049 13.0 2.71 1249 0.01 6 all 2638 0.049 13.0 1.94 5119 0.01 20 Partitions 12C-0sw: Wood stud frame, siding or stucco, no board insulation, R-13 cavity insulation Windows 61A: Vinyl Frame: Double Pane, clear low-e Doors 71A: Metal door, paper honeycomb, with storm Ceilings 16B-30ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-30 insulation Floors 91A-B: Tile covered basement Floor, No insulation, 67' wide 950 0.091 13.0 6.73 6394 0.33 311 n 152 0.350 0.0 25.9 3947 4.90 747 n 80 0.350 0.0 25.9 2072 4.90 392 s 90 0.350 0.0 25.9 2331 4.90 441 w 19 0.350 0.0 25.9 492 4.90 93 w 20 0.350 0.0 25.9 518 4.90 98 all 361 0.350 0.0 25.9 9360 4.90 1771 n 55 0.320 0.0 23.7 1298 0.00 0 s 41 0,320 0.0 23.7 967 0.00 0 all 96 0.320 0.0 23.7 2265 0.00 0 59 0.032 30.0 2.37 139 1.34 79 3488 0.022 0.0 0.50 1757 0.00 0 Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:39 C:Mmments and Seltirgs\Dmft3\Desk1optSD.rrp Calc = MJe Odentation = N Page 4 AED Assessment Job: SHAUN & DEANNA Date: AUGUST 12, 2005 Entire House By: Kelli Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 Project Information For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Design Conditions Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 68 75 Elevation: 4741 ft Design TD (°F) 74 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 57.0 -31.5 Dry bulb (°F) -6 89 Infiltration: Daily range (°F) - 34 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Test for •'•Exposure Hourly Glazing Load Maximum hourly glazing load exceeds average by 78.3%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 501 Btuh (PFG - 1.3*AFG) Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:39 C:\Documents and Servings\DraftMDeskloplSD.rrp Cale = MJ8 Orientation = N Page 1 SHA DEANNA AED Assessment r' Job: AUGUN8 2,2005 Date: AUGUST 12, 2005 UPPER By: Kalil Bakke KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 r-roject intormation For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 440N Outdoor: Heating Dry bulb (OF) 6 Daily range (OF) Wet bulb (OF) Wind speed (mph) 15.0 m B Design Conditions Indoor: Indoor temperature (OF) Design TD (OF Relative hums ity M Cooling Moisture difference(gr/lb) 89 Infiltration: 34 ( H) Method 60 Construction quality 7.5 Fireplaces Test for Adequate Exposure Diversity Hourly Glazing Load Maximum hourly glazing load exceeds average by 78.3%. Heating Cooling 68 75 74 14 50 50 57.0 -31.5 Simplified Average 0 Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 21 Btuh (PFG - 1.3*AFG) Right -Suite Residential 6.0.18 RSR40859 2005-Aug-1308:10:39 C:\Documents and Settings\Draft3\DesM0p\SD.nrp Calc=MJ8 Orientation=N Page AED Assessment ZONE1 KENT & KENT HEATING CASCADE DRIVE, IDAHO FALLS, IDAHO, 83401 For: SHAUN & DEANNA RESIDENCE MADISON COUNTY, REXBURG, ID Job: SHAUN &DEANNA Date: AUGUST 12, 2005 By: Kell! Bakke Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 68 75 Elevation: 4741 ft Design TD (°F) 74 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 57.0 -31.5 Dry bulb (°F) -6 89 Infiltration: Daily range (°F) - 34 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Test for • •Exposure Hourly Glazing Load U' Ma) J Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 480 Btuh (PFG - 1.3*AFG) Right -Suite Residential 6.0.18 RSR40859 2005-Aug-13 08:10:39 C:\Documents and Settings\Draft3\Desktop\SD.rrp Cale = MJ8 Orientation = N Page 3