HomeMy WebLinkAboutCHECKLISTS - 05-00182 - 652 Vale Ln - New SFRRESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) Date: "7- /-05— Prod ect: C.FTY/�t Gor f Zionng. Z-_4P)K 1 Building Permit Number: C -O vv�.;5. �/-, Job Address: � I � Number of Stories: �� Basement: es No/ Fixe. Unfin, Floor Area (sfl): 1'1745 finished,, unfinished, Valuation; $ Permit Fee: $ sr � garage Fixtures: 2,6 Plan Check Fee: $ The following comments based on the 20Q3 edition of the Intemational Residential Coale should he resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and Specifications dogs not permit the violation of any section of the Intema-fin- I esidenfiwa! Code or an state or local regulations. PLAN CHECK A. , lans T o Scale //Plot Plan �egible lood Plain V ///F106r l Foundation Plan f Section showing construction details / .A.l1 Building Elevations /Design Criteria shall be �den�ified o�plans aWind- ( s S 5 m.p.h., Snow -0I /eIruss Calculation Sheets & ///Floor Joist Details Mecham*cal Design //Energy Calculations (R320 & Ch 11) B. Zoning (check one - in some cases LDR2 and MDR may apply) LDR jZLDR1 Lot aea — LDR- 12,000 sq. ft. min. (width 80 (Width6o fit. min.).( LDR1 dtiplex - 10,000 sq. ft. min.) 35 lb. Per sq ft.) �r federal, ft. min) & LDRI.- 8,,000 sq. ft. min C. Tose I., Single Family Duplex (LDRI only Conditional use_permit? D. 5 Backs (taken from eaves) Fxont set back (32 ft. from curb) Ote: 60% min of front yard green ,/'R"ear set back (LDR 25 ft. & LDRI 20 ft.) 'Szides set backs 0" for every ft. of building height wi /,Building-He�gh� maximum 3 C} ft.) th LDR - 7.5'min., & LDRI - 6min.) E*F tings Proper Size (as per Table 4x3. 1, use 1540 psf unless sail type �s kM��u�n, Table 4aI,4.1 far sail bearing) .�' Rebar (2-#4 continuous) Footing depth (.36" below finished grade and 12" below undisturbed sail; 1$" to tap of slab — interior T. F ndatior� 7Foundation walls wl rebar (cityordiiaance) 1/2" Anchor Bolts with 2"x 2"x 3/16" square washers incl. interior bearing walls) R403.1.6.1 Foundation Drainage (found-ations on sift sail shall be designed per R405) Damp proofing/Waterproofing to finish grade. R406.1 (fnd, extends 6" min above grade R404.1.6) Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M 13 0 5.1.4), ; Crawl Space within 3' Ventilat ion/Insulat ion =1 sf'vent per ISO sf. ('with moisture barrier 1 sf. of each corner (insulate walls vent to inside of hone) R408.2 .�`/�Grading slope away from house. R401.3 G. Frame ZSeismic Hold Downs and Braced Wall Panels (R602.10) (Floors jsized as per R502.3, Wood 1 -joists sized per manufr. Joists Under Load Bearing Partitions shall be doubled. 8542.4 Girders sized per R502.5 or per manufr. Tables for engineered products Xcantile-N7ers (comply witla. R502.3.3 or manuft instruction) er 1500 s . ft.) and 4W. - Floor Sheathing (3/4" min for joists 24" oc & 5/8" for joists 16" oc) 8503.1 .� wa11 (bearing and nonbearing) stud saes, height & spacing per Table 602.3(5) R602.3 ,Headers ion Bearing Wall shall be designed asperTables 502.5(1&2) R602.7 Roof Trusses (designed according to R802.10.1� )5 # Snow and 9 D mph winds (Local Conditions) ZFand Truss die -downs. (R802.10.5) ,07 Attic Access 22" x 3011 min.. opening (R807) H. Exterior Covering Masonry and stucco shall lave weather resistive bam-er over exterior sheathing R703.2 & 703.9.1 I. Roof Covering and Ventilation "e-4 ovfVentilation as per R806 /A�sphalt Sbingles(slope>2:12)�vl xceprotection. (Other type: J. F 4' ewalls Garage/House drywall separation (protect ext. to comply w/ R905. ) walls chi beams supporting habitable spaced R309.2 r L onr from (_iarage to House (13/8" so1id wood or steel door,, or 20 min. fire -rated door), R309.1 Two Family Dwelling Separation (1 hr fire separation) Su Pporting structure also rated. R317.1 'win homes & Townhouses (Z hr separation & 4' overburn protection or parapets 8317.2 �'One hr walls parallel to and within 3 ft of property line vv1 NO openings. x.302 Penetrations in previous 3 items to comply with 8317.3 K. eneral Requirements House Numbers 8321 //"Ralf Openable 3 sf window or Mech. Ventilation in b-fcithrooms., water closets, and similar rooms. R303,3 Interior and exterior stair illumination shall comply with R303.6,P Bathroom Fixture clearances campy with Figure R307.2 One room at feast 12Q sf., __ether habitable rooms 70 sf_ min wl a min_ diamensionof 7 ft. R344 *areas -w/sloped ceilings less than 5 ft in height &Jurred ceilings less than ? ft DO NOT comply *50% or more of the required area must be at least 7ft high in rooms w1sloped ceiling d f Egress clearance from window welds under cantilevered floors. R310.2 Glazing at Hazardous Locations R308 �mergency Egress in all sleeping roams and basements with habitable space R310 �ne required Exit Door shad comply with R311.4 Landings at top and bottom of stairways 8311.5.4, and each side of each exterior, do -or. 8311.4.3 /'Stffl-rRis Run(73/4"max.fise&10"min. tairway Headroom (6-8" mina e ' d if � 1 � " Sta�� Width 3 6" min �.r-ead, nasing r q ) �( ), andrails (34"to 38r' above stair nosing) (R-311.5) �Pecial conditions for circular, spiral and winder stairways and bulkhead enclosures R311-5-8 Sta"rway Protection (enclosed accessible space under stairs shall be covered with. 1/2" drywall) R311.2.2 //Guardrails complying with 8312 /Handrails complying with 8311.5.6 make Alas (each bedroom and common area and one on each level) (R 313) L. Energy '`'Hames with glazing < 15% of giros area of ext, walls (Townhouses < 2S%) to comply wl *otherwise shall meet requirements of IECCfog respective building tyke. N1101-2 Vapor retarder on warm in winter side of walls, ceiling and floors R318 /I*Water Heater heat traps IECC 504.7 Duct sealing and insulation N1103.3&4 or IECC 563.3.3.3, 503.3.3.4.3 Xns matchquantities & values on a "passing" REScheck compliance report M. Mechanical Gas appliances not in bedrooms, bathrooms,, toilet roams, or storage closets G2406.2 Chapter 11. Room access 24" min width/Attic access clear apen�nb 20x3O/Under floor no2 . 2x30, M1305 6y ----Potential vent/connector offset > 75% of dotal height (Exception provided by G242$) G2427.6.4 f _Z� ]ryer Vent length 2S' maw wl S' transition (5' per 90 dig burns) M1501.3 Gas "point of delivery" and material used to detemine pips sizing. G2413