HomeMy WebLinkAboutRESCHECK - 05-00181 - 165 S Hidden Valley Rd - New SFRREScheck Compliance Certificate
20U0 IECC
REScl7eckSofM7are Version 3.6 Release 1
data filenaime: Untitled. rek
PROJECT TITLE.- Papworth
CITY: Rexburg
ST'AT'E: Idaho
HDD: $693
CONSTRUCTION TYPE: Single Family
WfNDOW / WALL RATIO: a. 11
DATE: 06115105
DATE OF PLANS: May- 15, 2005
DESIGNER/CONTRACTOW
Treat Harris Construction
COMPLIANCE: Passes
Maximum UA = 400
Your Home UA = 317
20.8% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
jvt�0 Wall 1: Wwd Frame, 16" p.G.
Window 1 : LTi rayl Frame: Doubt e Pane with Low -E
Door I-, Solid
n&o Basement Wall 1: Solid Concrete or Masonry
Mall height.- 8.01
I]epth below grade.- 6.5'
Insulation depth--, 8_0'
Furnace 1: Forced dot Air, 90 AFUIH
Air Conditioner L. Electric Central Air, 10 SEER
0500181
Ifiddell vajjcv No& 4 Lut 7)
Checked By/Date
Gross Glazing
Area, or Ca�jty Cont. or Door
Lemimoer R-Yalug g7vai=
-u.F
185,2,yee' 0.. 0 42.0
63i 23.0 Q.()
179
77
1852 ILO 0,0
0
43
76
59
15
124
- 1h
le, . �
01/1
GOl'rWLIANCE STATEMENT: The pro sed building designdes�rib�d here is consistent with the building plus,
specifications, and other calculations submi.ited with the permit application. The proposed building has been designed to
meet the 2000 IECC re
quirernents in RESchee%Versian 3.6 Release 1��ortx��rly ME�IzecRj and to comply with the
lnandator�� requirements luted in the REScl�eckInspeciian Cbecklist.
Builder/Designer d
.e,o
h
.date f _e1_y'f
REScheck Inspection Checklist
2000 IECC
RES check -Software Version 3.6 Release i
DATE-. 06!15/05
PROJECT TITLE: PapAvorth
Ceilings:
I. Ceiliwt I - Flat Ceiling or Scissor Truss,, R-42.0 continuous insulation
Comments-,
a 'k
ADOV'e-GradeWAls:
F Wall : Wood Frame, " ox_, R-23.0 cavity insulation
colmilents-b
]BasementWalls:
1. Basement Wall { Solid Concrete or Malo 8.0' h . 1. insul,,
R- I I . 0 cavity insulation
Caimnents-,
Windows+
.1. Window 1 � Vinyl Frame:Dauble Pane with Low -E, U -factor: (}.330
Fir windows without labeled 'U -factors, describe features:
# Panes Frame Type Thermal Break? Yes No
Comments-,
Doers:
I. Dour 1: Solid, U -factor- 0.200
Comments:
Heating and Cooling Equipment:
L Furnace l: Forced Hat Air, 90 AFUE or Ifigher
Make and Model Number
2, Air Conditioner l: Electric Central Aix, 14 SEER or Ifigher
Make and Model Number
Air Leakage:
Joints, penetrations', and all other such openings xn the building envelope that are sources ofair
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2} installed inside an appropriate air -fight assembtyr
w1th a 0. 5" clearance from combustible matenials. If non -IC rated, the fixture must be installed With a
3" clearance from insulatiom.
Vapor Retarder:
Required on the warm -in -winter side of all non vented framed ceilings, walls, and floors.
WO
0
Materials Mcnfifleation,
Materials and equipment mint be installed in accarc�n�e with the manufacturer's installation instructions.
Materials and equipment must be i�denii�fied so that compliance can be deternu'ned.
Manufacturer manuals for all installed heating and cooling equipment and ser�ce crater heating
equipment must be proVided.
Insulation R-iralues., glazing U -factors, and heating equipment efficiency must be clearly marked on
the building pans or specifications.
Duct Insulation:
Ducts in uncv�nditioned spaces must be M'sulated -to R-5.
Ducts outside the building must be insulated to R-8.4.
Duct COIIS#rliCtiOII.
.All joints, stens; and connections mush be securely fastened with virelds, gaskets, mastics (adliesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 18]. A ox UL 1$1B,
Exception." Continuously welded and lacking -type longitudi joints and semis on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system mush provide a means for balancing air and w�ater systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
parfially restrict or shut off the heating and/or cooling input to each gone or floor shill be provided,.
SenTice Water Heating:
Water heaters with vertical pipe risers must have a heat trap on. both the inlet and outlet unless the
water heater his ars integral heat. trap or i'5 pert of a circulating system_
Insulate circulating hot water pipes to the levels in Table 1.
Gretdating Hit Water Systems:,
Insulae circulating hot water pipes to the le�.riels in T, -Ale 1.
Swimming P0018.06
All heated swmum*ng gaols mush have an on/off heater switch and require a cover unless over 20%
of the heating energy �s froni non-depletable sources. POo1 pumps require a time stack.
Heating and Cooling Piping Insulation:
HVAC piping conveying B U'ids abo�,,e 105 'F or c
levels in Table Z.
hilled fluids below 55 OF Must be insulated to the
fable Minimum Insulidjol, ThieknessforCirculating Hot Water pipes,,
® _— — I i _— r"11 _" _ '1 - ' T +l t iia i
Heated �Vater
m F
170-lSd
I4a-160
104-1300.5
Circulatine
1,511 to 20"
1.5
1.0
0.5
Table Z: Minimum Insulalion Thacknessfor HVAC P�.pes.
Fluid Temp. I-nsullton
PIDiag.S.yaIgm T3mes Ran F 2" Lmiouts
Heating Systems
Low Pressure/Temperature
Low "Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Nater, Refrigerant,
and Brine
Mm
Maim aad- Runouts
In IRCh.0 PID9, .-SiZ?.SV mn&Lcu 2.5 #0 tq, V
21-250
1.0
L5
1.5
2-
120-200
0.5
1.0
1.0
1-5
Ait�v
1.0
1.0
1.
NOTES TO FIELD (Building Department Use Only)
0.75
1
Below 40
1-0t0
L5
NOTES TO FIELD (Building Department Use Only)