Loading...
HomeMy WebLinkAboutRESCHECK - 05-00171 - 654 Meadowbrook St - New SFRREScheck Compliance Certificate Z000 JECC REScheckSoftware Version 3.6 Rek;ase I Data filename. C:\Program Ff1eslChecklRESchecklFarkinson Residence.rck PROJECT 'TI'iI,E: Parkinson Residence CITY.- Rexburg STATE: Idaho HDD- 8693 CONSTRUlk"_11TION TYPE: Single Family WINDOW 1 WALI. RATIO.- O. 10 DATE.- 06f06/05 DATE OF PLANS: June 2, 2005 PROJECT DESCRIPTION.- 1540 ESCRXPTIQN:I544 SF .Ranch. DE S ICarNEItlCONTRAG TOR: R Hili Construction CONMLIANCE: Passes Ma-cvdmum UA = 362 Your Home UA = 323 10.8% Better Than Code (UA) Gross Area or 05700171 Permit Number Checked By/Date Glazing Cavity cont, carDoor 2eri=er -Value-.ValesU-FaLtor'� Ceiling 1. Fiat Ceiling or Scissor Truss 1540 3 8. 0 fl -d 46 �0 # WO 1: Steel Frame, 24" o. c. 1512 22. 0 0,0 171 Window 1 : Vinyl Franie;Dou61e Pane with Low -E 115 4.340 39 Door 1 : Glass 40 4,500 20 Door 2: Solid 47 O. 160 8 Basement Will 1 : Solid Concrete or Masonry 1544 13.0 O.(} 91 ihraPl height: $.0' mm" Depth below grade: 7.0' Insulation depth: $.0` � Floor I: All -Wood Joist/Tru ss -Over Outside Au- 1.89 22_0 0_0 g Furnace I : Forced Hat Air, 92 AFUIE Air Conditioner 1 : Electric Central Air., 10 SEER C(3MFLIAINCE STATEMENT.- The proposed building design. described here is consistent with the building plans, specificatic�t�s, and other calculat e�tls submiti�d wiih the perm�[t ap�Iicatic�r�_ T��e proposed building his been designed to meet the 2000 IIECC requirements in RES checkVersian 3.6 Release I (formerly NEC check) and to comply with the mandatory requiremen�ied in the RES pheckLnspect"on Checklist. II REScheck Inspection Checklist 2000 IECC REScheckSofiware Version 3.6 Release 1 DATE-. 06/06/05 PROJECT TITi.E: Parkinson Residence Bldg, Dept. Use Ceilings. I . Ceiling I : Flat Ceiling or Scissor Trus s R-38. 0 cavitynl 1 . Comments-, Above -Grade Walls: I . Wall I -. Steel Frame - 11 . C. - 2 . in 1 Comments: Basement'V'4'alls: 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7,,0'bg/8.0'insuI, R-110 cavity 'insulation Con=ents.- Windows;p I . Window 1 : Vinyl Frame -+Double Pare with Low -E, LT -factor: 0.340 For windows without labeled U -factors, describe features- 9 - banes Frame Type Thermal Break? F I Yes No Comments: Doors: 1. Door 1: Class, U -factor: 0.500 Comments.- 2. Door 2: Solid., U'factor-.- 0.16U comments: Floor. rt Floor L All-WoodJoist/Truss'.,Over Outside Air, R-22.0 avity insulation Comments.- Reating and Cooling Equipment; 1. Furnace I : Forced Hot Air, 92 AFUE or higher Make and Model Number 2. Air Conditioner I.- Electric Central Air, IQ SEAR_ or higher Make and Model Number Air Leaakage: Joints, penetrations, and all other such openings in the building envelope that are sources of sir leak -age must be seed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air. -fight assembly with a 0.5" clearance from combustible materials. Ifnon�IC rated, the fixture must be installed with a 310 clearance from insulation, Vapor Retarder: Required on the warm -i I n-)mnter side of all non -vented frartied ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's instailatianinstructions. Materials and equipment must be -identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided, Insulation R -values, glazing i.J-factors, and heating equipment efficiency must be clearly marked on she building plans or specifications, Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be 'Insulated to R-8.0. Duct Construction: All Joints, seams, and connections must be securely fastenedv�ith welds, gaskets, mastics (adbesives), mastic -plus -embedded. -fabric, or tapes. Tapes and mastics must berated ATL 18 1A or UI. 18 IR Exception: Continuously welded and locking -type longitudinal joints and, searns on ducts operating at less than 2 in. w.g. (500 Pa), The HVAC system must provide a means for balancing air and water Systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or coohng input to each zone or floor shall be provided, Service Water Heating: Water heaters with vertical piperisers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating, system. Insulate circulating hot water pipes to the levels in Table I. Circuiatiag Hot Water Systems: Insulate circulating had water pipes to the levels in Table I I SW'Mming Pools: All heatedswimming poOIs must have an onloff heater SvAtch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and hng pi Coo4 I ping Insulation: HVAC pipi nv ing fluids above 105 OF or chilled fluids below 55 must be insulated to the ing co eyl levels. in Table 2. 7 Table 1: Min Emu m In su lafio n Th ickn ess fvr Hea.#ed 'mater Ingggio Tcm2eL@gIre.,,� F� 170-18d 140-160 goo -13o0.5 CcHot Mater Pipes. . Tfkkness i by Pvnp Lq' k7ble 2: Minimum ,Insulation ThXckness, far HVAC Pipes, Fluid 'Temp. PID'"a Sy=m TRansw-(F), Heating Systems Law Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled mater, Refrigerant, and Brine t � � t Ins and Run -out Over 2 It 1*1 1s 1. jn.sulfTNkeinIInches ,b.&" SR.izes wft 1'RunQut, 1 " Less 1, " 1 .Ltg 4 201-250 1.0 1.5 1.5 2,0 120-2'00 0.5 Lo 1,0 1.5 Any 1.0 1.0 .+ 40-55 0_5 o.s 0.75 1.0 Below 40 1.4 1.0 1.5 1.5 NOTES TQ FIELD (Building Department Use Only)