LOAD SHORT FORM - 21-00431 - 811 S 2315 W - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:19 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Load Short Form Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C* AHRI ref 2002183 Coil Capf3030bx AHRI ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh69000 Sensible cooling Btuh16100 Heating output Btuh52440 Latent cooling Btuh6900 Temperature rise °F62 Total cooling Btuh23000 Actual air flow cfm920 Actual air flow cfm767 Air flow factor cfm/Btuh0.026 Air flow factor cfm/Btuh0.054 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 604 14506 4917 372 267 Room2 52 0 0 0 0 Room3 150 2249 279 58 15 Room4 250 4404 2415 113 131 Room5 242 2040 1414 52 77 Room6 169 2805 1442 72 78 Room7 50 749 165 19 9 Room8 154 2146 1116 55 61 Room9 132 2793 1153 72 63 Room10 35 969 596 25 32 Room11 82 3198 646 82 35 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:19 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2 S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W Entire House d 1920 35859 14143 920 767 Other equip loads 1821 335 Equip. @ 0.94 RSM 13610 Latent cooling 0 TOTALS 1920 37680 13610 920 767 2021-Jun-11 14:01:19 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Building Analysis Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation:5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F)SimplifiedMethod)H(34-Daily range (°F) AverageConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing DoorsCeilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 27.6104134.9Walls 21.4805622.8Glazing 2.490022.0Doors 4.717771.5Ceilings 12.246003.93.9Floors 26.8101144.0Infiltration 00Ducts00Piping00Humidification4.81821Ventilation0Adjustments100.037680Total Cooling Walls Glazing Other Ceilings InfiltrationVentilation % of loadBtuhBtuh/ft²Component 6.910000.5Walls 74.91083930.7Glazing 1.52195.4Doors 6.89820.8Ceilings 0.91340.1Floors 6.79690.4Infiltration 00Ducts2.3335Ventilation00Internal gains 00Blower0Adjustments100.014478Total Latent Cooling Load = 0 BtuhOverall U-value = 0.070 Btuh/ft²-°F Data entries checked. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Component Constructions Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) AverageConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2730.4728454.9422.00.065576n 2330.4724214.9422.00.065490e 2470.4725694.9422.00.065520s 2480.4725774.9422.00.065522w 10000.47104134.9422.00.0652108all Partitions (none) Windows 61C: 61C; NFRC rated (SHGC=0.32); 6.67 ft head ht 0.3009n 9210.320522.80 460934.1307822.800.300135e 120918.6148222.800.30065s 492834.1329122.800.300144w 1083930.7805622.800.300353all Doors11P0: Door, mtl pur core type 2195.3790022.010.50.29041e Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 9820.8417771.5250.00.0201169 Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 1/2" gypsum board int fnsh 1340.407292.1730.00.034336 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh 00377727.010.00.355140 009427.010.00.3553 00387127.010.00.355143all Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Project Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75Design TD °F76 Design TD °F14Daily range HRelative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh35859 Structure Btuh14143DuctsBtuh0DuctsBtuh0Central vent (26 cfm)1821 Btuh Central vent (26 cfm)Btuh335Outside air Outside airHumidificationBtuh0Blower Btuh0PipingBtuh0Equipment load Btuh37680 Use manufacturer's data nRate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh13610 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh-1347Ducts Btuh0Central vent (26 cfm)Btuh-466CoolingHeatingOutside air19201920Area (ft²)Equipment latent load Btuh01728017280Volume (ft³)Air changes/hour 0.260.50 Equipment Total Load (Sen+Lat)Btuh13610Equiv. AVF (cfm)75144 Req. total capacity at 0.70 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI...Model GMH950703BX Cond GSX130241C*AHRI ref 2002183 Coil Capf3030bxAHRI ref 4765510Efficiency95 AFUE Efficiency 11.0 EER, 13 SEERHeating input Btuh69000 Sensible cooling Btuh16100Heating output Btuh52440 Latent cooling Btuh6900Temperature rise °F62 Total cooling Btuh23000Actual air flow cfm920 Actual air flow cfm767Air flow factor cfm/Btuh0.026 Air flow factor cfm/Btuh0.054Static pressure in H2O0.70 Static pressure in H2O0.70Space thermostat Load sensible heat ratio 1.00 2021-Jun-11 14:01:20 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:AED Assessment Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F))H(34-Daily range (°F) 60-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 25.8%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Entire House Room1 2 Exposed wall 278.0 ft 101.0 ft3Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft604.0x1.0 5 Room area 1920.0 ft²604.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 585 576 2845 273 180 180 889 85.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 9 0 205 92 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 666 490 2421 233 216 140 692 67 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 135 0 3078 4609 35 0 798 1195 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 41 41 900 219 41 41 900 219 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 585 520 2569 247 297 267 1319 127 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 65 0 1482 1209 30 0 684 558WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 666 522 2577 248 216 144 710 68 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 144 0 3291 4928 72 0 1649 2470CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 1169 1169 1777 982 22 22 33 18 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 336 336 729 134 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 773 140 3777 0 604 101 2725 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 60 3 94 0 0 0 0 0 6 c) AED excursion 0 -269 Envelope loss/gain 25745 13174 10400 4538 12 a)Infiltration 10114 969 3675 352 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)35859 14143 14074 4890 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution004312714Subtotal3585914143145064917 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 35859 14143 14506 4917 Air required (cfm)Air required (cfm)920 767 372 267 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room2 Room3 2 Exposed wall 17.0 ft 25.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft4.0x13.0 ft15.0x10.0 5 Room area 52.0 ft²150.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 36 36 178 17 0 0 0 0.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 117 117 578 56 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 135 135 667 64 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 90 90 445 43 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 150 150 228 126 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 52 17 459 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -17 -41 Envelope loss/gain 1214 56 1339 192 12 a)Infiltration 618 59 910 87 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1833 115 2249 279 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution-1833 -115 0 014Subtotal002249279 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2249 279 Air required (cfm)Air required (cfm)0 0 58 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 3S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room4 Room5 2 Exposed wall 31.0 ft 14.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft250.0x1.0 ft242.0x1.0 5 Room area 250.0 ft²242.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 135 85 420 40 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 50 0 1140 1707 0 0 0 0 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 144 109 538 52 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 35 0 798 651 0 0 0 0WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 126 101 499 48 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 25 0 570 854CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 250 250 380 210 242 242 368 203 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 60 3 94 0 6 c) AED excursion -353 261 Envelope loss/gain 3276 2307 1530 1366 12 a)Infiltration 1128 108 509 49 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4404 2415 2040 1414 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal4404241520401414 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4404 2415 2040 1414 Air required (cfm)Air required (cfm)113 131 52 77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 4S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room6 Room7 2 Exposed wall 26.0 ft 5.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.0x13.0 ft5.0x10.0 5 Room area 169.0 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 117 117 578 56 45 36 178 17.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 9 0 205 92.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 117 92 454 44 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 25 0 570 854 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 169 169 257 142 50 50 76 42 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 50 50 108 20FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 257 -24 Envelope loss/gain 1859 1351 567 147 12 a)Infiltration 946 91 182 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2805 1442 749 165 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal28051442749165 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2805 1442 749 165 Air required (cfm)Air required (cfm)72 78 19 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 5S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room8 Room9 2 Exposed wall 14.0 ft 23.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x11.0 ft12.0x11.0 5 Room area 154.0 ft²132.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 18 18 89 9 108 108 534 51.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 99 74 366 35 99 74 366 35 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 25 0 570 854 25 0 570 854 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 9 9 44 4 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 154 154 234 129 132 132 201 111 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 154 154 334 62 132 132 286 53FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -26 -31 Envelope loss/gain 1637 1067 1956 1073 12 a)Infiltration 509 49 837 80 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2146 1116 2793 1153 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2146111627931153 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2146 1116 2793 1153 Air required (cfm)Air required (cfm)55 61 72 63 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-11 14:01:20Right-Suite® Universal 2019 19.0.13 RSU20477 Page 6S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room10 Room11 2 Exposed wall 7.0 ft 15.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x7.0 ft82.0x1.0 5 Room area 35.0 ft²82.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 81 81 400 38.GG 61C61C 0.3000.300 nn 22.8022.80 10.2810.28 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 11 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0WWFrm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 63 51 252 24 54 44 217 21 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 12 0 274 410 10 0 228 341CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 35 7 189 0 82 15 405 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 137 105 Envelope loss/gain 714 571 1250 506 12 a)Infiltration 255 24 546 52 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)969 596 1796 558 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution0014028814Subtotal9695963198646 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 969 596 3198 646 Air required (cfm)Air required (cfm)25 32 82 35 Job #: SF9B13 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 62 Page 1 Right-Suite® Universal 2019 19.0.13 RSU20477 2021-Jun-11 14:03:25 ...\Wrightsoft\SF9B13 princeton.rup N 2nd Story Room3 Room4 Room5 Room6 Room7 Room8 Room9 77 cfm 61 cfm 171 cfm 86 cfm 65 cfm 58 cfm 65 cfm 78 cfm 19 cfm 61 cfm 72 cfm 78 cfm 72 cfm Job #: SF9B13 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 62 Page 2 Right-Suite® Universal 2019 19.0.13 RSU20477 2021-Jun-11 14:03:25 ...\Wrightsoft\SF9B13 princeton.rup N Main Floor Room1 Room2 Room10 Room11 36'-0" 6 " 93 cfm 93 cfm 93 cfm 93 cfm 32 cfm 82 cfm 479 cfm 6 " 14x3.25 6 " 2-14x3.25 12 x 8 6 " 14x3.25 6 "6 " 6 " 6 "6 " 6 " 6 "6 " 20 x 8 20 x 8 3-14x3.25 14x3.25 14x3.25 12 x 8 6 " 12 x 8 6 " 2021-Jun-11 14:01:21 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W SF9B13Job:Duct System Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.177 / 0.183 in H2O in H2O0.177 / 0.183 Lowest friction rate in/100ft0.081in/100ft0.081 Actual air flow cfm767cfm920 Total effective length (TEL)ft445 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1B180.039.0ShMt0x06.00.08167933626hRoom1 st1150.023.0ShMt0x06.00.10267933626hRoom1-A st1B170.049.0ShMt0x06.00.08167933626hRoom1-B st1A180.038.0ShMt0x06.00.08167933626hRoom1-C st1165.012.0ShMt0x06.00.1003225596cRoom10 st1175.011.0ShMt0x06.00.09535823198hRoom11 st1A150.038.0ShMt0x06.00.09415582249hRoom3 st1A170.041.0ShMt0x06.00.08465561208cRoom4 st1A160.046.0ShMt0x06.00.08665561208cRoom4-A st1130.025.0ShMt0x06.00.11477521414cRoom5 st1160.016.0ShMt0x06.00.10178721442cRoom6 st1175.09.0ShMt0x06.00.096919749hRoom7 st1140.033.0ShMt0x06.00.10261551116cRoom8 st1175.020.0ShMt0x06.00.09163722793hRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 920 767 0.081 828 13.7 20x8 ShtMetl st1A Peak AVF 450 346 0.081 675 10.7 12x8 ShtMetl st1 st1B Peak AVF 186 133 0.081 279 7.7 12x8 ShtMetl st1A 2021-Jun-11 14:01:21 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2 S:\High Country\Wrightsoft\SF9B13 princeton.rup Calc = MJ8 House faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 720 78 105.0 0.174 248 4.8 3.25x14 10x9 SJSp rt1 rb4 0x 550 61 96.0 0.190 191 4.2 3.25x14 10x9 SJSp rt1 rb3 0x 720 63 127.0 0.144 227 4.8 3.25x14 10x9 SJSp rt1 rb1 0x 4790 334 226.0 0.081 505 10.9 3-3.25x14 3-10x27 SJSp rt1 rb6 0x 720 86 141.0 0.130 271 5.2 3.25x14 10x9 SJSp rt1 rb5 0x 1710 146 194.0 0.094 270 7.2 2-3.25x14 2-10x18 SJSp rt1A Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 920 767 0.081 828 13.7 20x8 ShtMetl rt1A Peak AVF 171 146 0.094 256 7.2 12x8 ShtMetl rt1