HomeMy WebLinkAboutREVIEW ACTION - 05-00158 - Steel Line - Office Buildingko R,..,EXBUR.,G- June 7, 2005 Permit Number-,: 05 00158 Project Name: Project Type: Review Item Steel Line Commercial New Building Department Review Mechanical Review Height and Area Review Building fdin Type Compliance Miscellaneous Complies with approved Site Plan Review Energy Conservation Compliance Review Miscellaneous Accessibility Review Exiling Review Plumbing Sewer Grin Review Plumbing Stora Drain Review Plumbing Potable Water Review Water and Sewer Service Review Action Asti r Mechanical sizing meets code requirements. Height and area meet the requirements of the Code. Building is Type li B. Construction materials used must meet the requirements of Section 6D3 of the 2x03 International Building Code (1BC). Provide 4" gravel under concrete slab as per IBC. The windows next to the trona entrance must be safely glazing. As a note, male and female restrooms will be required if an occupancy of 15 is exceeded in either side of the building. Site plan has been reviewed. Waiting for revisions. Provide energy calculations as per the 20Q3 International Energy Conservation Cade (IECC), Review Action faxed to TriSteele - John M to review today 06/07/2005 Provide handicap parking space. This space must be on shortest route to entrance of building. Provide accessible route to public right-of-way as per Section 1104 of the 2003 International Building Code. Provide emergency lighting at foyers and hails, P.0 Box 280 Rexburg, Idaho 83440 Phone (2(i8) 359-3020 Fax (2a8) 359-3022 06/03/2005 06/03/2005 06/03/2005 CITY OF EXBUf.,G NMEMCA5 FAMILY CO MM QTY June 7, 2005 ig Permit Number: 05 00158 Project Name: Project Type: Review Item Steel Line Commercial New Building Code Fire Compliance Review Structural Review Parcel #'s RFR.XBCA0365440 Review Action RO Box 280 19 E. Main St. Rexburg, 1daha 8344 Phone (208) 359-3020 Fax (208) 359-3022 ions- Required dor Approval ApRroved Provide sectional view details to identify ceiling construction. Provide letter form special inspection firm identifying the inspections that will be performed and the frequency of the inspections. Special I nspections are required for high strength bolting, concrete, structural fill and any fend welding. CITY f- _ _ - URG EXB -y Lis" June 7, 2005 Permit Number: 05 00158 Project Name: Project Type: Review Item Steel Line Commercial New .. Fire Delpartment Review Fire Access Fid Automatic Fire Extinguishing Systems mrrir i I Cooking Other Comments Alarm Systems Standpipes Fire Extinguishers Required Fire Fiero Water Supply Parcel #'s RPRXBCA0365440 Review Action r PROVIDED NOT REQUIRED NOT REQUIRED WITH OCCUPANCY KNOX BOX STRONGLY RECOMMENDED. CONTACT FIRE DEPARTMENT FOR MORE INFORMATION. NOT REQUIRED NOT REQUIRED TWO FIRE EXTINGUISHERS, MINIMUM SIZE OF 2A1013C REQUIRED WITHIN TRAVEL DISTANCES. P.' Box 280 1 E. Main St. Rexburg, Idaho 83440 Phone (208) 359-302 Fax (208) 359-322 wil,9ifevka 05/24/2005 05/24/2005 05/24/2005 05/24/2005 05/24/2005 05/24/2005 05/24/2005 1500 GPM/TWO HOURS, MINIMUM DISTANCE 06/05/2005 FROM HYDRANT IS 500 FEET. SITE PLAN HAS NO FIRE HYDRANTS SHOWN. ADVISED BY CITY ATTORNEY STEVE ZOLLINGER TO APPROVE SUBMITTED PLANS WITHOUT REQUIRED WATER SUPPLY AVAILABLE AS PER MAYOR LARSEN. 06!05/2005