HomeMy WebLinkAboutRESCHECK - 05-00156 - 524 Golden Willow Dr - New SFRREScheck Compliance C.-Wer�i�cate
2U04 IEC
KEScheck-Software Version 3.G Release I
Data filename.- C:\PROGRA— 11ChecklRESchecklSpec## 13.rck
PROJECT TITLE: Dave Harms 413
CITY: Rexburg
STATE: Idaho
HDD: 8693
CONSTRUCTION TYPE: Single FamiIy
WINDOW 1 WALL RATIQ: x.10
DATE: 05,110105
DATE OF FLANS: May 6, 2005
PROJECT UESCRI�'T1t7N:
Main Floor 2205 sq ft with hi I I basement (2205)
DESIGNER/CON TRT
Ntwl lIr
COMPLIANCE. Passes
Maximum STA = 3 94
Your Nome UA = 307
22. I %Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
�q 2�
Wall [.-Wood Frame, 24" O.C.
Window I'VinylV41 Frame. -Double Pane with Low -E
Dove I: Solid
Basement Wall 1: Solid Concrete or Masonry
Wall beight: 8.01
Depth below grade: 6.8'
Msulativn depth-- 7.9`
Fumace 1 Forced Hot .ire 90 AFUE
Gress
Area or
0:�r_
Fermat Number
�O s
Cfiecked Bv/Date
Cavity Cont.
Glazing,
or Door
Perimeter- aiu Rte- t�e -Factor �A
2205 � 0.0 38.0 55
1647 23.0 0.0 75
166 0.350 58
60 � 0.240 14
1647 1 LO 0.0 105
a"
45?
COMPLIANCE STATEMENT.- The proposed building designdescried here is consistent with the building plans,
specifications, and other calculations submWed with the permit application. The proposed building has been designed to
meet the 2004 IEGG requirements m SES checkVersion 3.6 Release I (fonnerly MECcliecl� and to comply with the
mandatary requirements listed. in the RES cheeklns�aection Check�isf.
"EScheck Inspection Checklist
2000 IECC
RES check Svffivare Version 3.6 Release
DATE. 05I10145
PROJECT TITLE: Dave Harris #13
:bldg,
Dept.
Use
Ceilings:
I. Ceilhlg 1: Flat Ceilingr Scissor Truss R-38.0 cont n us insulation
Comments-*
Above -Grade Walls:
I Wal I I - Wood Fram e 24 0 C., R-23 0 .�ttn
Comments
1
Basement Watts:
I. Basement Wall 1: Solid Concrete or Masora -y, 8.0'ht/6.8'bg/7.9ins-u1,
R- I 1 .0 cavity insulation
Comments.-
Windows:
omments.Win;
1. Window I Vinyl Frame:'Double Pwi withLow-E.U-factor: 0.350
For window. without labeled -factors describe features.
Panes FrameThermal Yes
� Break? � � +.�•
Corrments.
Doors
I , moor I-_ Sofid, U -factor. 0.24
FConu-nents-,
heating and Cooling Equipment;
[ � f 1 . Furnace I : Forced Hot .Air, 90 AFUE or higher
' Malo and Model Number
� Air Leakage:
faints, penetrations, and all ocher such openings in the building envelope that are; sources of air
� leakage must be sealed.
[ � � Recessed lights must be I ) Type IC rated, or 2} installed inside an appropriate air -tight assembly
� with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
�
311 clearance from insulation -
Vapor Retarder:
[ ) �
Required on the warm -ars. -winter side of all non -vested framed ceilings, wads, and floors..
�
Materials Identification:
] i Materials and equipment mist be installed is accordance with the maaufacturer's installation instruct -ions.
e
� ] J Materials and equipment must be identified so that compliance can be detennl*ned,
� ] I
Manufacturer mailtials for all instal -led heafiD.gaiid cooling equipment and service water heating
�
equipment must be provided.
[ � �
Insulation R -values, gfazing U -factors, and heating equipment ef�icienay mush be clearly marked on
� the building pans or specifications.
i
� Duct Insulation:
� 1 f
Ducts in unconditioned spaces must be insulated to R-5.
r Ducts outside the building must be insulated to R-8.0.
I?UCt CQIIStiuCilOn:
[ � � Ail joins, seams, and connections must be securely fastened with welds, baskets, mastics (adhesives),
� mastic -plus -embedded -fabric, or tapes. Tabes and mastics must be rated UL 181 A or LTL, 1$1 B.
j Exception.• Continuously welded and locking -type. longitudinal joints and seams on ducts
� operating at less than 21n- w.g. (500 Pa).
� ] i The HVAC system must provide a meas foirbalmicig sir and water systems.
Temperature Controls:
[ ] � 'Thermostats are required for each separate HVAC system. A manual 4r automatic means to
J partially restrict or shit off the heating and/or cooling input to each none or floor shall be provided.
� Service Water Heating:
Water beaters with vertical pipe risers mush have a heat trap on bath the inlet and outlet mless the
j water heater has an integral heat trap or is pact of a circulating system.
[ J � Insulate circulating hot wader pipes to the levels in Table 1.
i
j Circulating Hit Wader Systems:
[ � � insulate circulating hot water pipes to the levels in Table 1 _
� Swimming Pools:
[ ] � All heated swimming pools must have an onlvffheater switch and require a cover unless over 20°r0
�
of the heating energy is from non-depletaale sources. Pool pumps require a time eIock.
( Heating and Cooling Piping Insulation:
[ � � HVAC pip
Ing conveying fluids above 105 OF or chilled fluids below SS OF must be insulated to the
� levels in Table 2.
Table 1: Minimum Insulalion Thickness_ for Circulating Hat Water Pipes.
InsuIatian Thickness in Inches bv Pine �i
Heated Water
Tern erature F
170-180
X40-160
100-I30
Npn-C,i-rcu1afinv,.R,ung=Ci,rculatinfz I
!.
L12, LO -1j2
to a � . It
to
1„
1.5
0.5 0.5 1.
0.5 0.
A.
nd Runoi
Table 2.- Minimum Insulation Thicknessfor HVA C Pipes.
Fluid Temp. Insulation Thickness al Inches bv pine Sr
Pi* S stem TVDeS Ranae, f F
Heating Systems
Low Pressure/Temperature
Law Temperature
Steam Condensate (for Feed water)
Coling Systems
Chilled 'Water, Refrigerant,
and Brine
2v' unIItanLess 1,25"Lo211 2`511 to 411
201-250
1.0
1.5
1.5
2.0
120-200
0.5Lo
1.5
Any
1.0
Lo
1.5
.
40-55
0.5
0.5
0.75
L
Below 40
Lo
11.5
1.5
NOTES 7`U FIELD (Building Department Use Only)