HomeMy WebLinkAboutRESCHECK - 05-00155 - 544 Golden Willow Dr - AdditionRecheck Compliance Certificate 2000 IECC RASeheckSoftware vetsian 3. 6 Release 1 Data filename: C:lPROGRA---I1C,hecklRESc.hecklSpec # 14.rck PROJECT TITLE.- Spec # 14 CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW /WALL RATIO: 0. 14 DATE.- 05110105 DATE OF PLANS: Apri19 2005 PROJECT DESCRIPTI(7N. 1895 sq ft on main floor with full basement and 702 sq ft on garage DESIGNER/CONTRACTOR: David Harris C(3MPLIANCE: Passes. Maximum UA:;-- 373 Your Home UA = 3 10 16.E°/a Better Than Code (UA) Ceifing'l: Flat Ceiling or Scissor Truss Wail i : Wood Frame, 24" o C. Window 1. Vinyl FrameDouble Pane with Low -E Door I.- Sofid Basement Wall 1 Solid Concrete r Masonry Wall height: 8,01 Deptb below grade.- 6.8' Insulation depth: 7.91 FuniaceI : Forced Hot Air, 90 AFUE Gross Area r Permit Number Checked By/Date azin. Cavity Cont. or poor Perimeter R:Yalue R-YA.We U -Factor 4-1.898 �r I5 84 227 60 1584 y 0 "e, Wt,� a); ^-a[ M. 0.0 2,31.0 38.0 47 0.0 69 0.35a 79 0.240 1.4 0.0 iot COMPLIANCE STATEMENT: The proposed bufld'x�g des' gn descr"bed dere is consistent with the building plans, Specifications, and other calculations submitted with the permit application. The praposed building his been designed to meet the 2400 TECO requirements in RES checkVersion 3.6 Release ] (formerly MECchec)4 and to comply with the mandatory requirements listed in the RES checkinspectian Checklist. REScpheck Inspection Checkli'st 2000 IEC REScheckSoflware Version 3.6 Release 1 BATE: 05110105 PROJECT TITLE: Spec # 14 Dept. Use f i � Ceilings: Ceiihig 1; Fiat Ceiling or Scissor Truss, R-38.0 continuous insulation C Comments-. � Above -Grade Walls: 1, VG'aJd 1; Woad Frame,, 24" Q .c., R-23.0 cavity uIsulatian Comments - Basement Walls: [ ] � 1. Basement Wall I: Solid Concrete or Masozu-y, 8.0` 17116.8' bg,'7.9` 1*nsul; J R-1 1.0 cavity �nsulativrl � Comments: f I Windows: � ] � I, Window I: Vinyl Frame, -,Double Pani with Law -E, U -factor: x.350 � For windows without labeled U -factors, describe features-. � # Panes Frame Type Thermal Break? Yes. [ ] No j Comments-, � Doors: 1. Door 1: Solid, U -factor: 0.240 � Comments., � Heating and Cooling Equipment: � ] f I . Furnace l :Forced Not Air, 90 AFUE 4r hider � Make and Model Number. � Air Leakage: f Joints, penetrations, and all ether such openings in the building envelope that are sources of au � leakage must he sealed. [ ] � Recessed lights must be .1} Type IC raked, or 2} installed inside an appropriate air -tight assembly � with a D.SrR clearance from combustible materials. If non -IC rated, the fixture must be installed with a � 3" clearance from insulation. � 'Vapor Retarder: [ ) � Required an the warm -in -winter side of all non -vended framed ceilings, walls, and floors. � Materials Identification: [ ] � Materials and equipment must be �nstalled in accordance with the manufacturer's installation instructions. [ � J Materials and equipment must be identified so that compliance can be determined. [ � � Manufacturer maiivals for all, installed heating and cooling equipment and service water heating equipment must be provided. [ ] � Iusulation R -values, glazvig U-factoxs, and beating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ) � Ducts in unconditioned spaces, must be insulated to R-5. Ducts outside the building must be insulated to R-8,0. Duct Construction - It [ ] j All ,points, seams, and connections must be securely fastened with welds-, gaskets, mastics (adhesives), I mast] c-pl us -embedded -fabric, or tapes. Tapes and mastics must be rated UL 18 1A or UL 1 8 1 B. Exception.- Continuously welded and locking -type longitudinaljots and seams on ductsoperating at less than 2 in. w.g.- (500 Pa).. � ] � he HVAC system must provide a means for balancing air and water systems. Temperature Controls: � � j Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ � � Water beaters with vertical pipe risers must have a heat tra on both the ��tP0 ss the water beater has an integral beat trap or is part of a circulatm�g system - Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems. � ] f Insulate circulating hot water pipes to the levels in Table I Swimming Pools: [ � I All heated swimming pools must have an on/off beater switch and require a cover unless over 20% of the heating energy i's -from non-depletable sources. Pool pumps require a time clock. Heating and COORR9 Piping Insulation: � � ! HVAC pxpmg conveying fluids above, 105 OF or chilled fluids below 55 T must be insulated to the levels 'in Table 2. Table Minimum Insulation Thicknessfor Circulating Hot Water Pipes. Heated Water jLisulation Thickness in hiches by..PIP�L.Size� L!on-Ci,,. Runouts Circulatina.e ains and T'em erature F 170-I8Q 140-1G0 104-13Q t 1.251t .1t - '� It to 2.0;1 Over r 0.5 1. 0.5 . 1.0 1.5 0.5 0.5 0.5_ TaUle 2: Minimum Insulation Thicknessfo r H VAC Fres. Fluid Temp. Insulation Thicknevc in Tnrhpc hAina 1Q;�a� Pi!)�RM m e� R e --- Heating Systems Low Press ure1Temperature Low Temperature Steam Condensate (for feed water) Cooling systems Chilled Water, Refrigerant, and rifle 2" Runouts I " and Le 1625" to 200. 2-5 It to " 201-250 Lo 1.5 1.5 2.0 120-200 0.5 1.0 1.0 1. Any 1.0 1.0 1.5 2. 40-55 0.5 0.50.75 1.0 Below 1.0 1.0 1,5 1.5 NUTS TO FIELD (Building Department Use flnJy)