June 10, 2005
Permit Number: 05 00142
Project Name:
Project Type,,
Review Action
Madison Ridge Chiropratic
Commercial New
Review Item
Fire Department Review
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Marr System
Other Comments
Parcel #'s
RPRVLYWO020010
IM
Actions Required for Approval
2,000 GPM/TWO HOURS
ESTABLISHED
ESTABLISHED
EXTINGUISHERS SHOWN, PROVIDE ONE
EXTINGUISHER NEAR FRONT COMMON
AREA
NOT REQUIRED
NOT REQUIRED
A KNOX BOX IS STRONGLY
RECOMMENDED. CONTACT THE FIRE
DEPARTMENT FOR INFORMATION.
l�
P-0 Box 0
19 F. Main St.
Rexburg, Idaho 83440
Phone (208) 359-320
Fax (208) 359-322
.-Approved
05/18/2005
05/18/2005
05/18/2005
05/18/2005
05/18/2005
05/18/2005
05/18/2005
05/18!2005
05/18/2005
CITY OF
.�f�-E,XB'U'Po,,-G
June 10, 2005
Permit Number: 05 00142
Project Name:
Project Type:
Review Item
Review Action
Madison Ridge Chiropratic
Commercial New
Plumbing Storm Drain Review
Plumbing Potable Water Review
Building Code Fire Compliance Review
Structural Review
Parcel #'s R-PRVLYWO020010
Actions RgqmfireA—for AWroval
Shower required to have minimum of 3011 circle
for shower staff.
Treatment roams may be required to have hand
wash sinks.
Provide plans showing roof drain locations and
sire for review. All piping is to be
instalied ,tested and inspected before covering.
NQ Plumbing plans provided. Please submit
details for plumbing system.
Show location of mechanical ream.
Show backflow device locations.
Basement must be sprinklerec# as per Section
aus.Z. i U Wine zuu3 International Building Code
The structural calculations were made using
" exposure g" for wind evalution. The location of
the building necessitates a C exposure.
Special inspections are required for high
strength bolting and for on site welding. Provide
letter from the special insnertFnn firm that
identifies the frequency of the inspections.
Provide truss details prior to frame inspection,
RO Box 280
1 E. Main St.
Rexburg, Idaho 83440
Phone (los) 359-3020
Fax {248} 359-3022
1 0
CITY OF
f�.,EXBUR.G-
XNAFFLICA',S
F&%JJJ Y CDf1AMUN,]Ty
June 10, 2005
Permit Number: 05 00142
Project Name:
Project Type:
Review Action
Madison Ridge Chiropratic
Commercial New
Review Item
Building Department Review
Height and Area Review
Building Type Compliance
interior Environment,
Water and Sewer Service
Complies with approved Site Plan Review
Accessibility Review
Energy Conservation ComplianceReview
Mechanical Review
Exiting Review
Plumbing Sewer Drain Review
Actions Required for Approval
The upper floor meets the requirements of the
IBC.
Building is Type VB.
Wall and ceiling finishes must meet the
requirements of Section 803 of the IBC.
% � � W In, R
19 E. Main St.
Rexburg, Idaho 8344
Prone (208) 359-3020
fax (20$) 359-3022
06/0112005
06/01/2005
06/01/2005
All Plumbing services are required to be 06I0112005
installed Jested and inspected before covering.
Whit is the height of the water table at the
building site? Will a basement be pratical?
Provide details for attic ventilation as per
Section 1203,2 of the 113C. Identify weepholes
and flashing at bottom of brick veneer. Provide
two restrooms as per Section 2901. 1. The " dr.
Bathrm" is private and will not taunt against this
requirement.
Site plan has been reviewed and we are waiting
dor revisions.
Provide accessible access to the public right-
of-way.
Meets the requirements of the International
Energy Conservation Code for envelope and
lighting. Please provide mechanical.
Provide details dor mechanical. Where are the
HVAC units? How is the crawl space
mechanically vented? Provide design info as
per the 2003 iEnergy Consrevation
Code and the 2003 Mechanical Cade, Haw will
the requirements of Section 1203.4 of the IBC
be addressed?
M
Provide plans for drainage system.
All drains are required to be bested and
inspected before covering.