HomeMy WebLinkAboutREVIEW ACTION - 05-00142 - Madison Ridge Chiropractic - New BuildingCITY O f EXBU' R.G June 10, 2005 Permit Number: 05 00142 Project Name: Project Type,, Review Action Madison Ridge Chiropratic Commercial New Review Item Fire Department Review Required Fire Flow Water Supply Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Commercial Cooking Marr System Other Comments Parcel #'s RPRVLYWO020010 IM Actions Required for Approval 2,000 GPM/TWO HOURS ESTABLISHED ESTABLISHED EXTINGUISHERS SHOWN, PROVIDE ONE EXTINGUISHER NEAR FRONT COMMON AREA NOT REQUIRED NOT REQUIRED A KNOX BOX IS STRONGLY RECOMMENDED. CONTACT THE FIRE DEPARTMENT FOR INFORMATION. l� P-0 Box 0 19 F. Main St. Rexburg, Idaho 83440 Phone (208) 359-320 Fax (208) 359-322 .-Approved 05/18/2005 05/18/2005 05/18/2005 05/18/2005 05/18/2005 05/18/2005 05/18/2005 05/18!2005 05/18/2005 CITY OF .�f�-E,XB'U'Po,,-G June 10, 2005 Permit Number: 05 00142 Project Name: Project Type: Review Item Review Action Madison Ridge Chiropratic Commercial New Plumbing Storm Drain Review Plumbing Potable Water Review Building Code Fire Compliance Review Structural Review Parcel #'s R-PRVLYWO020010 Actions RgqmfireA—for AWroval Shower required to have minimum of 3011 circle for shower staff. Treatment roams may be required to have hand wash sinks. Provide plans showing roof drain locations and sire for review. All piping is to be instalied ,tested and inspected before covering. NQ Plumbing plans provided. Please submit details for plumbing system. Show location of mechanical ream. Show backflow device locations. Basement must be sprinklerec# as per Section aus.Z. i U Wine zuu3 International Building Code The structural calculations were made using " exposure g" for wind evalution. The location of the building necessitates a C exposure. Special inspections are required for high strength bolting and for on site welding. Provide letter from the special insnertFnn firm that identifies the frequency of the inspections. Provide truss details prior to frame inspection, RO Box 280 1 E. Main St. Rexburg, Idaho 83440 Phone (los) 359-3020 Fax {248} 359-3022 1 0 CITY OF f�.,EXBUR.G- XNAFFLICA',S F&%JJJ Y CDf1AMUN,]Ty June 10, 2005 Permit Number: 05 00142 Project Name: Project Type: Review Action Madison Ridge Chiropratic Commercial New Review Item Building Department Review Height and Area Review Building Type Compliance interior Environment, Water and Sewer Service Complies with approved Site Plan Review Accessibility Review Energy Conservation ComplianceReview Mechanical Review Exiting Review Plumbing Sewer Drain Review Actions Required for Approval The upper floor meets the requirements of the IBC. Building is Type VB. Wall and ceiling finishes must meet the requirements of Section 803 of the IBC. % � � W In, R 19 E. Main St. Rexburg, Idaho 8344 Prone (208) 359-3020 fax (20$) 359-3022 06/0112005 06/01/2005 06/01/2005 All Plumbing services are required to be 06I0112005 installed Jested and inspected before covering. Whit is the height of the water table at the building site? Will a basement be pratical? Provide details for attic ventilation as per Section 1203,2 of the 113C. Identify weepholes and flashing at bottom of brick veneer. Provide two restrooms as per Section 2901. 1. The " dr. Bathrm" is private and will not taunt against this requirement. Site plan has been reviewed and we are waiting dor revisions. Provide accessible access to the public right- of-way. Meets the requirements of the International Energy Conservation Code for envelope and lighting. Please provide mechanical. Provide details dor mechanical. Where are the HVAC units? How is the crawl space mechanically vented? Provide design info as per the 2003 iEnergy Consrevation Code and the 2003 Mechanical Cade, Haw will the requirements of Section 1203.4 of the IBC be addressed? M Provide plans for drainage system. All drains are required to be bested and inspected before covering.