HomeMy WebLinkAboutPLAN REVIEW RESPONSE - 05-00142 - Madison Ridge Chiropractic - New Buildingif June 6, 2005) City of Rexburg 19 E. Main St. Rexburg, ID. 83440 OS 0014"? 'Revised 6/9'().' Madison Ridge Chiro R Re: Plea Review Response for Madison Ridge Chiropractor Site Plan Pen -nit 905-00142 & OS 0014-) The fallowing items are modifications to the Bid Set Plans , as required b Y the City of Rexburcy building and fire departments. The information below and the drawings attached Will be incorporated into the contract documents. Item #S - 1Vliscelianeaus: a. Wader table/basement. Our research shows that there are established houses north of our site (between Highway 33 and tete Teton River) that have basements. Also, there are houses south of aut� site with basements. Per our submitted g��adrn��lan, we are building up our site which will reduce the depth of our basement. b. Attic ventilation details c. Identify weep holes and flashing at masonry veneer. Please refer to attached drawing sheet A-5, building sections. d. Provide two restrooms as per Section 290 1. 1. A second accessible restroom has been added, please refer to attached drawing sheets-1. e. X -Ray wail shielding. ,4n x-ray manufacturer and model has not been selected by the Ckwner at this time. Upon selection, the manufacturer's physicist will determine the required amount of shielding needed fog th is application_ Please refer to attached drawing t1- 1. stern #6 -- Site Pian Review-, a. Miscellaneous: 1. WiM their be a garbage dumpster. No 2. Provide handicap access from building to p.r.w. Please see attached drawingSD-j. b. 15' Setback from north property line. Per City ordinance the north side is a side yard per definition o, f a front y. c. identify Snow Storage. Please see drawing sheet SD- ], note X11 d.. End parkina spaces require back out area. Acknowledged, see attached df -awing SI] -1. Item 47 -Provide accessible access to the public right-of-way. accessible access has been added foam the properly to the right-of-way on highway 33, Please refer to attached drawing sheet SIS -1. Item #8 - IEEC Mechanical Analysis. Please refer to attached. 1152 Bond Avemia (208) 359-2309 'k - + 4*40 V rkfjgd BoraE _ Y N.C.A.R.B. Fax 359 - 2271 NATIONAL COUNCIL Off' RGHITE TU RE GI )'T:ATION BCARDS NIN'al3M wt; i C)jTSWjrXYC k 0 idem #9 - Mechanical Review: a. HVAC locations. Please see attached drcrw ing A -2. b.- Crawl space venting. Ventilation will be achieved with exhaust fans and humidistat. c. Section 1203.4 Natural ventincj. X411 occupied spaces tivithin the building will be vented mechanically per LVC. Item # 10 -- Plumbing'Sewer Drain Review a. Provide pians for drainage system. Please see attached drawing. b. All drains are required to be Tested and inspected before covering. Acknowledged. C. Shower required to have rr�inimum of 3 d" circle for shower sta�i. Showers shown do sheet A-1 are 34 "X34 " clear_ d. Treatment rooms may be required to have hand wash sinks. The treatments administered do not necessitate the need of a hand wash stations in the treatment rooms. Item 411 — Plumbing Storm Drain a. Show roof drain locations & size. Please refer to drawing A-9for roof drain location See .attached sheet P- 1 fo-r size. b. All pipingis to be installed, tested and inspected before covering. Acknowledged. Item #12 — Potable Maier Review a. Plumbing plans. Please .see attached drawing. b. Shove locat" of mechanical room. Please see attachedfloor plan A-2. c. Show backflow device location. Please see attached drawing. Item # 13 — Building Code, Fire Compliance a. Basement mist be sprinkler as per Section 903.2.,.10 IBS. The basement arevi be seduced to 1, 4 75 sq, ft. Please refer to drawing GI and A 2. Item # 14 — Structural Review a. Wind exposure `C' in lieu of `$'. Acknowledged. b. Special'inspection h.s. bolting & field welding. Prov-1de letter from special inspect�n firm identifying frequency of inspections. acknowledge, T2ATwill he retained as the special inspectors. Inspections will be periodic per AISCfor bolts and 14 WSfor welds. e. Provide truss details prior to frame inspections. Acknowledged. Should you have any further concerns or questions- pease do no hesitate to contact me or Johnny Watson. S incerely, Brent A. McFarland, A.I.A. t