HomeMy WebLinkAboutPLANS - 21-00422 - 261 Seagull Dr - Solar PanelsN 4 6 ' - 2 " 39'-7" 24'-0" 12'-7" 92'-2" 1 0 6 ' - 1 " 92'-2" 1 0 6 ' - 1 " R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " P V 0 . 0 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 S H E E T I N D E X : P V 0 . 0 : C O V E R S H E E T P V 1 . 0 : S I T E P L A N S 1 . 1 : M O U N T D E T A I L S E 1 . 1 : 3 - L I N E D I A G R A M E 1 . 2 : N O T E S E 1 . 3 : W A R N I N G L A B E L S - E Q U I P M E N T S P E C S H E E T C O V E R S H E E T S C A L E : N T S 2 S A T E L L I T E V I E W P V 0 . 0 S C A L E : N T S 3 V I C I N I T Y M A P P V 0 . 0 SCALE: 1/16" = 1'-0"1PLOT PLANPV 0.0 GENERAL NOTES:a.INSTALLATION OF SOLAR PHOTOVOLTAICSYSTEM SHALL BE IN ACCORDANCE WITHNEC ARTICLE 690, AND ALL OTHERAPPLICABLE NEC CODES WHERE NOTEDOR EXISTING.b.PROPER ACCESS AND WORKINGCLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENTWILL COMPLY WITH NEC ARTICLE 110.c.ALL CONDUCTORS, INCLUDING THEGROUNDING ELECTRODE CONDUCTORSHALL BE PROTECTED FROM PHYSICALDAMAGE IN ACCORDANCE WITH NECARTICLE 250.d.THE PV MODULES ARE CONSIDEREDNON-COMBUSTIBLE; THIS SYSTEM ISUTILITY INTERACTIVE PER UL 1741 ANDALSO INCLUDE STORAGE BATTERIES OROTHER ALTERNATIVE STORAGESOURCES.e.ALL DC WIRES SHALL BE SIZEDACCORDING TO [NEC 690.8]f.DC CONDUCTORS SHALL BE WITHINPROTECTED RACEWAYS INACCORDANCE WITH [NEC 690.31]g.ALL SIGNAGE TO BE PLACED INACCORDANCE WITH LOCALJURISDICTIONAL BUILDING CODE.h.PV MODULES TO BE RATED UL 1703CLASS C FIRE RATING OR BETTER.i.ALL EQUIPMENT TO BE CERTIFIED BY ANATIONALLY RECOGNIZED TESTINGLABORATORY.PROTECTION OF EMERGEN C Y R E S P O N D E R S ALL SHARP EDGES AND FA S T E N E R T I P S S H A L L B E COVERED OR CRIMPED OV E R T O E L I M I N A T E S H A R P EDGES, TO MINIMIZE RISK O F I N J U R Y T O E M E R G E N C Y R E S P O N D E R S . ALL ROOF MOUNTED COND U I T S , B O X E S , A N D E Q U I P M E N T CROSSING PATHWAYS ARE T O B E C L E A R L Y I D E N T I F I E D B Y A R E D / W H I T E REFLECTIVE TAPE OR OTH E R A P P R O V E D M A T E R I A L . R O O F A C C E S S P O I N T R O O F A C C E S S P O I N T S H A L L N O T B E L O C A T E D I N A R E A S T H A T D O N O T R E Q U I R E T H E P L A C E M E N T O F G R O U N D L A D D E R S O V E R O P E N I N G S S U C H A S W I N D O W S O R D O O R S , A N D L O C A T E D A T S T R O N G P O I N T S O F B U I L D I N G C O N S T R U C T I O N I N L O C A T I O N S W H E R E T H E A C C E S S P O I N T D O E S N O T C O N F L I C T W I T H O V E R H E A D O B S T R U C T I O N S S U C H A S T R E E L I M B S , W I R E S O R S I G N S . SYSTEM SIZE: 5.355 kW DC5.000 kW ACMODULE TYPE & AMOUNT:(17) JINKO SOLAR JKM315M-60HLMODULE DIMENSIONS:(L/W/H) 66.3"/39.45"/1.38"INVERTER:(01) SOLAREDGE SE5000H-US [240V]INTERCONNECTION METHOD: LOAD BREAKER PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLT A I C R O O F M O U N T S Y S T E M 17 MODULES-ROOF MOU N T E D - 5 . 3 5 5 k W D C , 5 . 0 0 0 k W A C , 2 6 1 S E A G U L L D R , R E X B U R G , I D 8 3 4 4 0 ROOF ACCE S S P O I N T R O O F # 1 ( 1 1 ) J I N K O S O L A R J K M 3 1 5 M - 6 0 H L S L O P E : 3 1 ° A Z I M . : 9 0 ° M FRONT OF HOUSE SEAGULL DR M A I N H O U S E G A R A G E DRIVEWA Y E X I S T I N G E X T E R I O R M A I N S E R V I C E P A N E L T I E D T O E X T E R I O R U T I L I T Y M E T E R # 6 6 7 9 9 0 6 9 P R O P E R T Y L I N E GOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES·2018 INTERNATIONAL BUILDING CODE·2018 INTERNATIONAL RESIDENTIAL CODE·2015 INTERNATIONAL FIRE CODE·2018 INTERNATIONAL MECHANICAL CODE·2019 INTERNATIONAL FUEL GAS CODE·2018 INTERNATIONAL ENERGY CONSERVATION CODE·2017 NATIONAL ELECTRICAL CODE·2018 INTERNATIONAL EXISTING BUILDING CODEPROPERTY LINEPROPERTY LINE P R O P E R T Y L I N E R O O F # 2 (06) JI N K O S O L A R J K M 3 1 5 M - 6 0 H L S L O P E : 3 1 ° A Z I M . : 1 8 0 ° N 6'-5"13'-5 " 1 0 ' - 1 " NEW PV ATTACHMENT AT 4'-0" O.C. 8'-8"23'-6"7'-10" R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " P V 1 . 0 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 E Q U I P M E N T L A Y O U T S I T E P L A N SCALE:1/8" = 1'-0"1SITE PLANPV 1.0 R O O F S E C T I O N ( S ) M O D U L E - 0 6 S L O P E - 3 1 ° A Z I M U T H - 1 8 0 ° M A T E R I A L - C O M P O S I T I O N S H I N G L E T R U S S S I Z E & S P A C I N G - 2 " X 4 " @ 2 4 " O . C . M O D U L E - 1 1 S L O P E - 3 1 ° A Z I M U T H - 9 0 ° M A T E R I A L - C O M P O S I T I O N S H I N G L E T R U S S S I Z E & S P A C I N G - 2 " X 4 " @ 2 4 " O . C . R O O F # 0 1 R O O F # 0 2 M O D U L E , A R R A Y W E I G H T ( L O A D C A L C ' S ) N u m b e r o f M o d u l e s 1 7 M o d u l e W e i g h t 4 1 . 9 L B S T o t a l M o d u l e ( A r r a y ) W e i g h t 7 1 2 . 3 0 L B S N u m b e r o f A t t a c h m e n t p o i n t 4 1 M o u n t i n g S y s t e m W e i g h t ( P e r M o d u l e ) 1 . 5 L B S M o u n t i n g S y s t e m W e i g h t 6 1 . 5 0 L B S T o t a l S y s t e m W e i g h t ( M o d u l e W e i g h t + M o u n t i n g S y s t e m W e i g h t ) 7 7 3 . 8 0 L B S W e i g h t a t E a c h A t t a c h m e n t P o i n t ( A r r a y W e i g h t / N u m b e r o f A t t a c h m e n t P o i n t ) 1 7 . 3 7 L B S M o d u l e A r e a ( 6 6 . 3 " x 3 9 . 4 5 " ) 1 8 . 1 6 S q F t T o t a l A r r a y A r e a 3 0 8 . 7 8 S q F t D i s t r i b u t e d L o a d ( T o t a l S y s t e m W e i g h t / T o t a l A r r a y A r e a ) 2 . 3 9 P e r S q F t T o t a l R o o f A r e a 1 4 3 4 S q F t T o t a l P e r c e n t a g e o r R o o f C o v e r e d T o t a l A r r a y A r e a / T o t a l R o o f A r e a ) * 1 0 0 2 1 . 5 3 % SYSTEM SIZE: 5.355 kW DC5.000 kW ACMODULE TYPE & AMOUNT:(17) JINKO SOLAR JKM315M-60HLMODULE DIMENSIONS:(L/W/H) 66.3"/39.45"/1.38"INVERTER:(01) SOLAREDGE SE5000H-US [240V]PHOTOVOLTAIC SYSTEM SPECIFICATIONS: S Y S T E M L E G E N D E X I S T I N G E X T E R I O R M A I N S E R V I C E P A N E L & P O I N T O F I N T E R C O N N E C T I O N . T I E D T O E X T E R I O R U T I L I T Y M E T E R # 6 6 7 9 9 0 6 9 . N E W P H O T O V O L T A I C U T I L I T Y D I S C O N N E C T S W I T C H . M A C N E W 0 1 - S O L A R E D G E S E 5 0 0 0 H - U S [ 2 4 0 V ] I N V E R T E R . I = C O N D U I T E X T E R I O R R U N = R O O F T O P J U N C T I O N B O X = A T T A C H M E N T P O I N T S = T R U S S = R O O F O B S T R U C T I O N S = F I R E P A T H W A Y = R A C K I N G S Y S T E M 1 7 N E W J I N K O S O L A R J K M 3 1 5 M - 6 0 H L M O D U L E S W I T H S O L A R E D G E O P T I M I Z E R M O U N T E D O N T H E B A C K O F E A C H M O D U L E S . ROOF #01 ACI NEW PV AC DISCONNECT GR O U P E D W I T H SERVICE EQUIPMENT (VISIB L E , LOCKABLE, LABELED)NEW SOLAREDGE SE5000 H - U S [ 2 4 0 V ] I N V E R T E R M EXISTING EXTERIOR MAIN SERVICE PANEL& POINT OF INTERCONNECTION. TIED TOEXTERIOR UTILITY METER #66 799 069 36" FIRE SETBACK 1 8 " F I R E S E T B A C K FRONT OF HOUSE SEAGULL DR 1 8 " F I R E S E T B A C K ROOF #02 S T R I N G # 2 - 0 8 M O D U L E S S T R I N G # 1 - 0 9 M O D U L E S S T R I N G ( S ) R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " S 1 . 1 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 M O U N T D E T A I L SCALE: NTS 2ATTACHMENT DETAIL ENLARGED VIEWS 1.1 SCALE: NTS 1ATTACHMENT DETAIL (SIDE VIEW)S 1.1 GENERAL STRUCTURAL NOTES:1.THE SOLAR PANELS ARE TO BE MOUNTED TO THEROOF FRAMING USING THE IRONRIDGE RACKINGSYSTEM WITH FLASH FOOT 2 ATTACHMENTS. THEMOUNTING FEET ARE TO BE SPACED AS SHOWNIN THE DETAILS, AND MUST BE STAGGERED TOADJACENT FRAMING MEMBERS TO SPREAD OUTTHE ADDITIONAL LOAD.2.UNLESS NOTED OTHERWISE, MOUNTINGANCHORS SHALL BE 5/16" LAG SCREWS WITH AMINIMUM OF 2-1/2" PENETRATION INTO ROOFFRAMING.3.THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THEROOF FRAMING SYSTEM.4.ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDERNEW PV SYSTEM.5.GROUND SNOW LOAD = 0 PSF6.WIND SPEED = 115 MPH7.EXPOSURE CATEGORY = B8.RISK CATEGORY = II P V M O D U L E ( E ) S I N G L E L A Y E R O F C O M P S H I N G L E R O O F I R O N R I D G E I N T E G R A T E D G R O U N D I N G & E N D / M I D C L A M P P V M O D U L E S I R O N R I D G E X R - 1 0 R A I L F L A S H I N G 2 " X 4 " T R U S S @ 2 4 " O C 5 / 1 6 " x 3 " S S L A G B O L T W I T H M I N 2 - 1 / 2 " T H R E A D E M B E D M E N T , S E A L E D P E N E T R A T I O N SEE (2/S 1.1) FORENLARGED VIEW I R O N R I D G E F L A S H F O O T 2 2 " X 4 " T R U S S @ 2 4 " O C R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " E 1 . 1 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 3 - L I N E D I A G R A M R o o f t o p c o n d u c t o r a m p a c i t i e s d e s i g n e d i n c o m p l i a n c e w i t h a r t . 6 9 0 . 8 , T a b l e s 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) , 3 1 0 . 1 5 ( B ) ( 3 ) ( a ) , 3 1 0 . 1 5 ( B ) ( 3 ) ( c ) , 3 1 0 . 1 5 ( B ) ( 1 6 ) , C h a p t e r 9 T a b l e 4 , 5 , & 9 . L o c a t i o n s p e c i f i c t e m p e r a t u r e o b t a i n e d f r o m A S H R A E 2 0 1 7 d a t a t a b l e s A M B I E N T T E M P ( H I G H T E M P 2 % ) R E C O R D L O W T E M P - 2 6 ° C 3 3 ° C C O N D U I T H E I G H T 0 . 5 " R O O F T O P T E M P 5 5 ° C C O N D U C T O R T E M P E R A T U R E R A T E 9 0 ° C INVERTER CHARACTERISTICS - SOLAREDGE SE 5000H-USMAX OUTPUT POWER5000WSYSTEM OPERATING VOLTAGE380VMAX CONTINOUS OUTPUT CURRENT21AMAX INPUT VOLTAGE480VSYSTEM SHORT CIRCUIT CURRENT15AMAX EFFICIENCY99%OPTIMIZER SPECIFICATIONSMANUFACTURERDC INPUT POWER320 W SOLAREDGE P320DC MAX INPUT VOLTAGEDC MAX INPUT CURRENTDC MAX OUTPUT CURRENT 48V13.75A15A P H O T O V O L T A I C S Y S T E M D C S Y S T E M S I Z E ( W A T T S ) N O M I N A L A C V O L T A G E 2 4 0 V 5 3 5 5 W A C S Y S T E M S I Z E ( W A T T S ) 5 0 0 0 W T O T A L N U M B E R O F M O D U L E S 1 7 1 2 0 % R U L E B U S B A R R A T I N G X 1 2 0 % ) - M A I N B R E A K E R R A T I N G = M A X . P V O C P D ( 1 2 5 A x 1 2 0 % ) - 1 0 0 A = 5 0 A WIREQTYWIRETAG #CONDUITWIRE TYPE S T R I N G W A T T A G E O P E R A T I N G V O L T A G E C O N D U I T F I L L : TEMPRATING:WI R E A M P T E M P D E - R A T E : W I R E O C P : M A X S Y S T E M V O L T A G E G R N D S I Z E WIREGAUGE: T E R M I N A L 7 5 ° C R A T I N G : N E C : M A X A M P S x x = / x = 1 . 2 5 3 8 0 V 2 8 3 5 W 9 . 3 3 A 3 8 . 4 0 A 3 5 A 90°C 3 5 A / x = 1 . 2 5 3 8 0 V 2 8 3 5 W 9 . 3 3 A x x = 2 4 . 3 2 A 90°C 5 0 A / x = 1 . 2 5 2 6 . 2 5 A x x = 4 7 . 0 0 A 75°C 4 0 A #104 0 A #105 0 A #8 3/4" EMT3/4" EMT WIRE FROM - -JUNCTION BOX TOINVERTERINVERTER TO MSP ARRAY TOJUNCTION BOX123PV WIRETHWN-2THWN-2 4 N / A 4 0 . 8 0 3 1 . 0 0 IN AIR / = = = = S T R I N G A M P S 7 . 4 6 A 7 . 4 6 A 2 1 A x = G R N D W I R E T Y P E 4 8 0 V 4 8 0 V 2 4 0 V # 6 # 8 # 8 S B C T H W N - 2 T H W N - 2 0 . 9 6 0 . 7 6 0 . 9 4 PV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC) 9 . 4 9 A M P S JINKO SOLAR J K M 3 1 5 M - 6 0 H L 3 3 . 2 V O L T S 4 0 . 7 V O L T S 1 0 . 0 4 A M P S NOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT 3 1 5 W A T T 1 0 0 0 V - 0 . 2 8 % / ° C MODULE:(17) JINKO SOLAR JKM315M-60HLINVERTER:(01) SOLAREDGE SE5000H-US [240V ] (N) SOLA R E D G E S E 5 0 0 0 H - U S [ 2 4 0 V ] I N V E R T E R O U T P U T : 2 4 0 V A C , 2 1 A 99% CE C W E I G H T E D E F F I C I E N C Y NEMA 3R, U L L I S T E D , I N T E R N A L G F D I WITH INT E G R A T E D D C D I S C O N N E C T ( U L 1 7 4 1 C E R T I F I E D ) G N ( N ) L O C K A B L E B L A D E T Y P E N O N - F U S I B L E A C D I S C O N N E C T N E M A 3 R 3 0 A - 2 P 1 2 0 / 2 4 0 V A C ( U L 1 7 4 1 C E R T I F I E D ) P O I N T O F I N T E R C O N N E C T , L O A D S I D E E X I S T I N G 2 4 0 V / 1 2 5 A B U S B A R R A T I N G , M A I N S E R V I C E P A N E L , S I N G L E P H A S E , W I T H A 1 0 0 A M A I N D I S C O N N E C T U T I L I T Y C O M P A N Y : R O C K Y M O U N T A I N P O W E R U T I L I T Y M E T E R # 6 6 7 9 9 0 6 9 3 17 NEW JINKO SOLAR JKM315M-60HL (UL1703CERTIFIED) MODULES WITH SOLAREDGEOPTIMIZER MOUNTED ON THE BACK OF EACHMODULES. 3 ( N ) P V B R E A K E R G N 1 0 0 A M 3 0 A ( E ) L O A D S ( E ) L O A D S E X I S T I N G G R O U N D I N G E L E C T R O D E S Y S T E M (N) JUNCTION BOX600 V, NEMA 4UL LISTED(UL1741 CERTIFIED)1 = A C D C 2 -++-+++---======-+2081 -++-+++---======-+2091 1 STRING OF 09 MODULES CONNECTED IN SERIES.1 STRING OF 08 MODULES CONNECTED IN SERIES. R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " E 1 . 2 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 N O T E S SITE NOTES:1.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.THE PV MODULESARECONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AUTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.3.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL,OR BUILDING ROOF VENTS.4.PROPERACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSEDELECTRICAL EQUIPMENT WILL BE PROVIDED AS PERSECTION NEC 110.26.5.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.EQUIPMENT LOCATIONS:1.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.2.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTEDOPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES310.15 (B)(2)(A) AND 310.15 (B)(3)(C).3.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.4.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOTWITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BEINSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NECAPPLICABLE CODES.5.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOORUSAGE WHEN APPROPRIATE.STRUCTURAL NOTES:1.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATEDSPACE BETWEEN MODULES, AND RAILS MUSTALSO EXTEND A MINIMUM DISTANCEBEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIMANUFACTURER’S INSTRUCTIONS.2.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IFROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.3.ROOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETED AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR.4.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHENPOSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGEREDAMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES:1.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS AREBASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.3.VOLTAGE DROP LIMITED TO 1.5%.4.DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.5.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACKPHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3-BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TOBE MARKED ORANGE [NEC 110.15].GRO U N D I N G N O T E S : 1. G R O U N D I N G S Y S T E M C O M P O N E N T S S H A L L B E L I S T E D F O R T H E I R P U R P O S E , A N D G R O U N D I N G D E V I S E S E X P O S E D T O T H E E L E M E N T S S H A L L B E R A T E D F O R S U C H U S E . 2. P V E Q U I P M E N T S H A L L B E G R O U N D E D A C C O R D I N G T O N E C 6 9 0 . 4 3 A N D M I N I M U M N E C T A B L E 2 5 0 . 1 2 2 . 3. M E T A L P A R T S O F M O D U L E F R A M E S , M O D U L E R A C K I N G , A N D E N C L O S U R E S C O N S I D E R E D G R O U N D E D I N A C C O R D W I T H 2 5 0 . 1 3 4 A N D 2 5 0 . 1 3 6 ( A ) . 4. E Q U I P M E N T G R O U N D I N G C O N D U C T O R S S H A L L B E S I Z E D A C C O R D I N G T O N E C 6 9 0 . 4 5 A N D M I C R O I N V E R T E R M A N U F A C T O R E R S ’ I N S T R U C T I O N S . 5. E A C H M O D U L E W I L L B E G R O U N D E D U S I N G W E E B G R O U N D I N G C L I P S A S S H O W N I N M A N U F A C T U R E R D O C U M E N T A T I O N A N D A P P R O V E D B Y T H E A H J . I F W E E B S A R E N O T U S E D , M O D U L E G R O U N D I N G L U G S M U S T B E I N S T A L L E D A T T H E S P E C I F I E D G R O U N D I N G L U G H O L E S P E R T H E M A N U F A C T U R E R S ' I N S T A L L A T I O N R E Q U I R E M E N T S . 6. T H E G R O U N D I N G C O N N E C T I O N T O A M O D U L E S H A L L B E A R R A N G E D S U C H T H A T T H E R E M O V A L O F A M O D U L E D O E S N O T I N T E R R U P T A G R O U N D I N G C O N D U C T O R T O A N O T H E R M O D U L E . 7. G R O U N D I N G A N D B O N D I N G C O N D U C T O R S , I F I N S U L A T E D , S H A L L B E C O L O R E D G R E E N O R M A R K E D G R E E N I F # 4 A W G O R L A R G E R [ N E C 2 5 0 . 1 1 9 ] 8. T H E G R O U N D I N G E L E C T R O D E S Y S T E M C O M P L I E S W I T H N E C 6 9 0 . 4 7 A N D N E C 2 5 0 . 5 0 T H R O U G H 2 5 0 . 1 0 6 . I F E X I S T I N G S Y S T E M I S I N A C C E S S I B L E , O R I N A D E Q U A T E , A G R O U N D I N G E L E C T R O D E S Y S T E M P R O V I D E D A C C O R D I N G T O N E C 2 5 0 , N E C 6 9 0 . 4 7 A N D A H J . 9. G R O U N D - F A U L T D E T E C T I O N S H A L L C O M P L Y W I T H N E C 6 9 0 . 4 1 ( B ) ( 1 ) A N D ( 2 ) T O R E D U C E F I R E H A Z A R D S DISC O N N E C T I O N A N D O V E R - C U R R E N T P R O T E C T I O N N O T E S : 1. D I S C O N N E C T I N G S W I T C H E S S H A L L B E W I R E D S U C H T H A T W H E N T H E S W I T C H I S O P E N E D T H E C O N D U C T O R S R E M A I N I N G E N E R G I Z E D A R E C O N N E C T E D T O T H E T E R M I N A L S M A R K E D “ L I N E S I D E ” ( T Y P I C A L L Y T H E U P P E R T E R M I N A L S ) . 2. D I S C O N N E C T S T O B E A C C E S S I B L E T O Q U A L I F I E D U T I L I T Y P E R S O N N E L , B E L O C K A B L E , A N D B E A V I S I B L E - B R E A K S W I T C H 3. P V S Y S T E M C I R C U I T S I N S T A L L E D O N O R I N B U I L D I N G S S H A L L I N C L U D E A R A P I D S H U T D O W N F U N C T I O N T O R E D U C E S H O C K H A Z A R D F O R E M E R G E N C Y R E S P O N D E R S I N A C C O R D A N C E W I T H 6 9 0 . 1 2 ( A ) T H R O U G H ( D ) . 4. A L L O C P D R A T I N G S A N D T Y P E S S P E C I F I E D A C C O R D I N G T O N E C 6 9 0 . 8 , 6 9 0 . 9 , A N D 2 4 0 . 5. M I C R O I N V E R T E R B R A N C H E S C O N N E C T E D T O A S I N G L E B R E A K E R O R G R O U P E D F U S E S I N A C C O R D A N C E W I T H N E C 1 1 0 . 3 ( B ) . 6. I F R E Q U I R E D B Y A H J , S Y S T E M W I L L I N C L U D E A R C - F A U L T C I R C U I T P R O T E C T I O N A C C O R D I N G T O N E C 6 9 0 . 1 1 A N D U L 1 6 9 9 B . INTE R C O N N E C T I O N N O T E S : 1. L O A D - S I D E I N T E R C O N N E C T I O N S H A L L B E I N A C C O R D A N C E W I T H [ N E C 7 0 5 . 1 2 ( B ) ] 2. T H E S U M O F T H E U T I L I T Y O C P D A N D I N V E R T E R C O N T I N U O U S O U T P U T M A Y N O T E X C E E D 1 2 0 % O F B U S B A R R A T I N G [ N E C 7 0 5 . 1 2 ( D ) ( 2 ) ( 3 ) ] . 3. T H E S U M O F 1 2 5 P E R C E N T O F T H E P O W E R S O U R C E ( S ) O U T P U T C I R C U I T C U R R E N T A N D T H E R A T I N G O F T H E O V E R C U R R E N T D E V I C E P R O T E C T I N G T H E B U S B A R S H A L L N O T E X C E E D 1 2 0 P E R C E N T O F T H E A M P A C I T Y O F T H E B U S B A R , P V D E D I C A T E D B A C K F E E D B R E A K E R S M U S T B E L O C A T E D O P P O S I T E E N D O F T H E B U S F R O M T H E U T I L I T Y S O U R C E O C P D [ N E C 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ] . 4. A T M U L T I P L E E L E C T R I C P O W E R S O U R C E S O U T P U T C O M B I N E R P A N E L , T O T A L R A T I N G O F A L L O V E R C U R R E N T D E V I C E S S H A L L N O T E X C E E D A M P A C I T Y O F B U S B A R . H O W E V E R , T H E C O M B I N E D O V E R C U R R E N T D E V I C E M A Y B E E X C L U D E D A C C O R D I N G T O N E C 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( C ) . 5. F E E D E R T A P I N T E R C O N E C T I O N ( L O A D S I D E ) A C C O R D I N G T O N E C 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) 6. S U P P L Y S I D E T A P I N T E R C O N N E C T I O N A C C O R D I N G T O N E C 7 0 5 . 1 2 ( A ) W I T H S E R V I C E E N T R A N C E C O N D U C T O R S I N A C C O R D A N C E W I T H N E C 2 3 0 . 4 2 2 . 7 . 8 B A C K F E E D I N G B R E A K E R F O R E L E C T R I C P O W E R S O U R C E S O U T P U T I S E X E M P T F R O M A D D I T I O N A L F A S T E N I N G [ N E C 7 0 5 . 1 2 ( B ) ( 5 ) ] . N R e v JULENE BASSETT RESIDENCE 261 SEAGULL DR, REXBURG, ID 83440 PHONE: (801) 636-8170 EMAIL: JUJUBASSETT@HOTMAIL.COM D a t e D e s c r i p t i o n R E V I S I O N S S i g n a t u r e w i t h S e a l P r o j e c t N a m e & A d d r e s s S h e e t S i z e S h e e t N u m b e r A N S I B 1 1 " X 1 7 " E 1 . 3 S h e e t N a m e D R A W N B Y APN: RPRHNDS0050020 37 N 2ND E, REXBURG, IDAHO, 83440 (208) 417-9908 W A R N I N G L A B E L S C A U T I O N : P O W E R T O T H I S B U I L D I N G I S A L S O S U P P L I E D F R O M T H E F O L L O W I N G S O U R C E S W I T H D I S C O N N E C T S L O C A T E D A S S H O W N U T I L I T Y M E T E R & M A I N S E R V I C E P A N E L A C D I S C O N N E C T I N V E R T E R A C M I S E A G U L L D R ( 1 7 ) P V M O D U L E S MACINVERTERJ/B PV ARRAY P E R C O D E ( S ) : N E C 2 0 1 1 : 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( b ) , N E C 2 0 1 7 W A R N I N G ! D O N O T R E L O C A T E T H I S O V E R C U R R E N T D E V I C E I N V E R T E R O U T P U T C O N N E C T I O N ! WARNING: PHOTOVOLTAICPOWER SOURCE(PER CODE: NEC 690.31(G)(3)(4) & NEC 690.13(G)(4))PER CODE(S): NEC 2017: 690.13(B)ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITION WARNING!! P H O T O V O L T A I C A C D I S C O N N E C T ( P E R C O D E : N E C 6 9 0 . 1 4 ( C ) ( 1 ) ) S O L A R P H O T O V O L T A I C S Y S T E M S ( P E R C O D E : N E C 6 9 0 ) L A B E L L O C A T I O N : A C D I S C O N N E C T , P O I N T O F I N T E R C O N N E C T I O N ( P E R C O D E : N E C 6 9 0 . 5 4 ) P H O T O V O L T A I C S Y S T E M A C D I S C O N N E C T R A T E D A C O P E R A T I N G C U R R E N T 2 1 A M P S A C N O M I N A L O P E R A T I N G V O L T A G E 2 4 0 V O L T S I N V E R T E R # 1 ( S O L A R E D G E S E 5 0 0 0 H - U S [ 2 4 0 V ] ) PHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNLABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECTIF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS ASREQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2011: ARTICLE 690.56(C): NEC 2017 S O L A R P H O T O V O L T A I C S Y S T E M S ( P E R C O D E : N E C 6 9 0 ) S O L A R P H O T O V O L T A I C S Y S T E M S ( P E R C O D E : N E C 6 9 0 ) PHOTOVOLTAIC DC DISCONNECTMAXIMUM SYSTEM VOLTAGE:MAXIMUM CIRCUIT CURRENT:MAX RATED OUTPUT CURRENT OF THE CHARGECONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED):VDCADCADC48014.115 INVERTER #1 (SOLAREDGE SE5000H-US [240V])LABEL LOCATION:INVERTER(S), DC DISCONNECT(S).PER CODE(S): CEC 2016: 690.53, NEC 2017: 690.53, NEC 2014: 690.53,NEC 2011: 690.53 A S O L A R P V S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N T U R N R A P I D S H U T D O W N S W I T C H T O T H E " O F F " P O S I T I O N T O S H U T D O W N P V S Y S T E M A N D R E D U C E S H O C K H A Z A R D I N T H E A R R A Y S O L A R E L E C T R I C P V P A N E L S A T I N V E R T E R [ I F C 6 0 5 . 1 1 . 3 . 1 ( 1 ) & 6 9 0 . 5 6 ( C ) ( 1 ) ( a ) ] P E R C O D E : N E C 2 0 1 7