Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 05-00106 - Rexburg Rehab - Tenant Finishc ty o f fc�xb �y C' 5-8 3836 1 CS18 3n$7 Permit N ber Envelope Compliance Certificate 2001 IECC COMcheck-EZ Software Version 3.0 Release 2 Data filename: Untitled.cck Section 1: Project Information Project Name: Rexburg Rehab Inside Strip Mall Designer/Contractor. Blanc Robbins Electric, Inc Document Author. Jeff Robbins Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Window / Wall Ratio: 0.00 S Checl6e By/Date Building Tne Floor Area Medical and Clinical Care 2500 Section 3: Requirements Checklist Bldg. Dept. Use Air Leakage, Component Certification, and Vapor Retarder Requirements [ ] 1 1. All joints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed. [ ] 2. Windows, doors, and skylights certified as meeting leakage requirements. [ ] 3. Component R-values & U-factors labeled as certified. Clintate-Specific Requirements Gross Area or Cavity Cont. Proposed Budget Component Name/Description Perimeter R-Value R- al e iJ Factor L1-Factor (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Envelope PASSES: Design 0.0%better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans, specilications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2001 lECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2 and to comply with the mandatory requirements in the Requirements Checklist. Principal Envelope Designer -Name Si� Date Lighting Compliance Certificate 2001 IECC COMcheck EZ Software Version 3.0 Release 2 Data filename: Untitled.cck Section 1: Project Information Project Name: Rexburg Rehab Inside Strip Mall Designer/Contractor. Blanc Robbins Electric, Inc. Document Author. JeffRobbins Section 2: General Information Building Use Description by: Whole Building Type Project Type: New Construction Permit Number Checked By/Date Building Type Floor Area Medical and Clinical Care 2500 Section 3: Requirements Checklist Bldg. Dept. Use Interior Lighting [ ] I 1. Total actual watts must be less than or equal to total allowed watts I Allowed Watts Actual Watts Complies(Y/N) 4000 3936 YES Exterior Lighting [ ] I 2. Efficacy greater than 45 lumens/W I Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring [ ] I 3. Independent controls fDr each space (switch/occupancy sensor). Faciption: Areas that must be continuously illuminated. [ ] ( 4. Master switch at entry to hotel/motel guest mom. [ ] I 5. Two switches or dimmer in each space to provide unifbrm light reduction capability. Exceptions: I Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, or lobby; Areas that must be continuously illuminated; Areas greater than 250 sq. I. Lighting Application Worksheet 2001 IECC COMcheck--EZ Software Version 3.0 Release 2 Section 1: Allowed lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Building Type (0 Lwatts/$2) fB x Cl Medical and Clinical Care 2500 1.6 4000 Section 2: Actual Lighting Power Calculation A B Fixture Fixture Description / iD Lamp Description / Wattage Per Lamp / Ballast 1 48" T8 32W / Electronic 2 Incandescent 60W Total Allowed Watts = 4000 C D E F Lamps/ # of Fixture Fixture Fixtures Watt- x E 3 31 96 2976 1 16 60 960 Total Actual Watts = 3936 Section 3: Compliance Calculation Ifthe Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 4000 Total Actual Watts = 3936 Project Compliance = 64 Lighting PASSES: Design 2% better than code 6. Automatic lighting shutoff control in spaces greater than 250 sq.1 in buildings larger than 5,000 sq.8. 7. Photocell/astronomical time switch on exterior lights. Exceptions: Areas requiting lighting during daylight hours 8. Tandem wired one -lamp and three -lamp ballasted luminaires. Exceptions: Electronic high -frequency ballasts; Luminaires not on same switch Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2001 IECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2 and to comply with the mandatory requirements in the Requirements Checklist. Principal Lighting Designer -Name ignature Date