Envelope Compliance Certificate
2001 IECC
COMcheck-EZ Software Version 3.0 Release 2
Data filename: Untitled.cck
Section 1: Project Information
Project Name: Rexburg Rehab
Inside Strip Mall
Designer/Contractor. Blanc Robbins Electric, Inc
Document Author. Jeff Robbins
Section 2: General Information
Building Location (for weather data): Rexburg, Idaho
Climate Zone: 16
Heating Degree Days (base 65 degrees F): 8693
Cooling Degree Days (base 65 degrees F): 143
Project Type: New Construction
Window / Wall Ratio: 0.00
S
Checl6e By/Date
Building Tne Floor Area
Medical and Clinical Care 2500
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Air Leakage, Component Certification, and Vapor Retarder Requirements
[ ] 1 1. All joints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed.
[ ] 2. Windows, doors, and skylights certified as meeting leakage requirements.
[ ] 3. Component R-values & U-factors labeled as certified.
Clintate-Specific Requirements
Gross
Area or Cavity Cont. Proposed Budget
Component Name/Description Perimeter R-Value R- al e iJ Factor L1-Factor
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
Envelope PASSES: Design 0.0%better than code
Section 4: Compliance Statement
The proposed envelope design represented in this document is consistent with the building plans, specilications and other
calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2001
lECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2 and to comply with the mandatory requirements
in the Requirements Checklist.
Principal Envelope Designer -Name Si� Date
Lighting Compliance Certificate
2001 IECC
COMcheck EZ Software Version 3.0 Release 2
Data filename: Untitled.cck
Section 1: Project Information
Project Name: Rexburg Rehab
Inside Strip Mall
Designer/Contractor. Blanc Robbins Electric, Inc.
Document Author. JeffRobbins
Section 2: General Information
Building Use Description by: Whole Building Type
Project Type: New Construction
Permit Number
Checked By/Date
Building Type Floor Area
Medical and Clinical Care 2500
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Interior Lighting
[ ] I 1. Total actual watts must be less than or equal to total allowed watts
I Allowed Watts Actual Watts Complies(Y/N)
4000 3936 YES
Exterior Lighting
[ ] I 2. Efficacy greater than 45 lumens/W
I Exceptions:
Specialized lighting highlighting features of historic buildings; signage; safety or security lighting;
low -voltage landscape lighting.
Controls, Switching, and Wiring
[ ] I 3. Independent controls fDr each space (switch/occupancy sensor).
Faciption: Areas that must be continuously illuminated.
[ ] ( 4. Master switch at entry to hotel/motel guest mom.
[ ] I 5. Two switches or dimmer in each space to provide unifbrm light reduction capability.
Exceptions:
I Only one luminaire in space; An occupant -sensing device controls the area;
The area is a corridor, storeroom, restroom, or lobby; Areas that must be continuously illuminated;
Areas greater than 250 sq. I.
Lighting Application Worksheet
2001 IECC
COMcheck--EZ Software Version 3.0 Release 2
Section 1: Allowed lighting Power Calculation
A B C D
Total
Floor Allowed Allowed
Area Watts Watts
Building Type (0 Lwatts/$2) fB x Cl
Medical and Clinical Care 2500 1.6 4000
Section 2: Actual Lighting Power Calculation
A B
Fixture Fixture Description /
iD Lamp Description / Wattage Per Lamp / Ballast
1 48" T8 32W / Electronic
2 Incandescent 60W
Total Allowed Watts = 4000
C D E F
Lamps/ # of Fixture
Fixture Fixtures Watt- x E
3 31 96 2976
1 16 60 960
Total Actual Watts = 3936
Section 3: Compliance Calculation
Ifthe Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies.
Total Allowed Watts = 4000
Total Actual Watts = 3936
Project Compliance = 64
Lighting PASSES: Design 2% better than code
6. Automatic lighting shutoff control in spaces greater than 250 sq.1 in buildings larger than 5,000 sq.8.
7. Photocell/astronomical time switch on exterior lights.
Exceptions: Areas requiting lighting during daylight hours
8. Tandem wired one -lamp and three -lamp ballasted luminaires.
Exceptions:
Electronic high -frequency ballasts; Luminaires not on same switch
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans, specifications and other
calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2001
IECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2 and to comply with the mandatory requirements
in the Requirements Checklist.
Principal Lighting Designer -Name ignature Date