CITY O F
REXBURG
OW
Americas Family Community
December 15, 2005
� P.o Box 280
lq ■ 19 E Main St.
Rexburg, Idaho 83"0
Phone (208) 359-3020
Review Action Fax (208) 359-3022
Permit Number: 05 00105
Project Name: Mama K's Tenant Finish
Project Type: Commercial Tenant Finish
Review Item Actions Required for Approval Ap roved
uil _.eQ pa`"rtiler_
Building Type Compliance Building type approved with building review. OK 04/07/2005
Height and Area Review Building height and area submitted with 04/07/2005
building. Construction with this area non-
structural -tenant finish.
Structural Review Structural details submitted with building. OK 04/07/2005
Complies with approved Site Plan Review
Accessibility Review
Exiting Review
Energy Conservation Compliance Review
Building Code Fire Compliance Review
Interior Environment
Mechanical Review
Site plan reviewed with origional building.
Restroom compartments are not ADA
compliant. Toilet compartment must be 60"
wide minimum. Door can not swing into the 59"
clear floor space (from the back wall of the
toilet) of the ada compartment.
Show details of ADA restroom - height and
location of accessories -sink, mirrors, grab
bars, and compartment details.
Exit doors must swing out of the building. Exit
doors must have exit signs and emergency
lighting. Post occupancy loads at exit doors
and doors to each of the rooms.
Provide energy talc's forMechanical,
and Electrical.
Need details of the oven hood system and
required chase protection.
Oven and hood details need to be submitted
showing hood and protection details.
Mechanical plans and details need to be
submitted showing talc's for FAU/AC and
ducting.
Details need to be submitted on dish washer
and hood system and if required.
04/07/2005
12/01 /2005
12/01 /2005
P.O Box 280
C� pexeugC,o CITY OF
19 E Main St.
REXBURG Rexburg, Idaho 83440
`1W Phone (208) 359-3020
'. Americas Family Community
' Review Action Fax (208) 359-3022
December 15, 2005
Permit Number: 05 00105
Project Name: Mama K's Tenant Finish
Project Type: Commercial Tenant Finish
Review Item Actions Required for Approval AR roved
Required Fire Flow 1500 GPM/TWO HOURS 05/14/2005
Water Supply ESTABLISHED 05/14/2005
Standpipes
Alarm Systems
Other Comments
Fire Access Roads
Fire Extinguishers
Commercial Cooking
Automatic Fire Extinguishing Systems
Parcel Vs RPRPNRV010040A
NOT REQUIRED 05/14/2005
NOT REQUIRED 05/14/2005
05/14/2005
ESTABLISHED 05/14/2005
CRY OF
RFYBURG
nmcxrns F,uur cawnunirc
Review Action
April 8, 2005
P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 3593020
Fax (208) 359-3022
Permit Number: 05 00105
Project Name: Mama K's Tenant Finish
Project Type: Commercial Tenant Finish
Review 1_tem
Actions Required for Approval
Approved
Building Department Review
Building Type Compliance
Building type approved with building review. OK
04/07/2005
Height and Area Review
Building height and area submitted with
04/07/2005
building. Construction with this area non-
structural -tenant finish.
Structural Review
Structural details submitted with building. OK
04/07/2005
Complies with approved Site Plan Review
Site plan reviewed with origional building.
04/07/2005
Energy Conservation Compliance Review
Provide energy calc's for Envelope, Mechanical,
and Electrical.
Accessibility Review
Restroom compartments are not ADA
compliant. Toilet compartment must be 60"
wide minimum. Door can not swing into the 59"
clear floor space (from the back wall of the
toilet) of the ada compartment.
Show details of ADA restroom - height and
location of accessories -sink, mirrors, grab
bars, and compartment details.
Mechanical Review
Mechanical plans and details need to be
submitted showing calc's for FAU/AC and
ducting.
Details need to be submitted on dish washer
and hood system and if required.
Interior Environment
Oven and hood details need to be submitted
showing hood and protection details.
Building Code Fire Compliance Review
Need details of the oven hood system and
required chase protection.
Exiting Review
Exit doors must swing out of the building. Exit
doors must have exit signs and emergency
lighting. Post occupancy loads at exit doors
and doors to each of the rooms.
CITY OF
REXBURG
a• S .B MtiR"$ "ILY CJ UNU7
Review Action
April 8, 2005
Permit Number: 05 00105
Project Name: Mama K's Tenant Finish
Project Type: Commercial Tenant Finish
Parcel #•s RPRPNRV010040A
P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
s CRY OF
REXBURG
A KL 5 FAMILY Cx)MMUN"
Review Action
April 8, 2005
Permit Number: 05 00105
Project Name: Mama K's Tenant Finish
Project Type: Commercial Tenant Finish
P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Review Item Actions Required for Approval Approved
Fire Department Review
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Other Comments
Parcel #'s RPRPNRV010040A
i CITY OF
REXBURG
A IUS FAMLY CAlr Mn
Review Action
April 7, 2005
Permit Number: 05 00106
Project Name: Rexburg Rehab
Project Type: Commercial Tenant Finish
P.O Box 280
19 E Main St.
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
Review Item Actions Required for Approval Approved
Fire Department Review
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Other Comments