Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SHORT FORM - 05-00102 - 362 Oaktrail Dr - New SFR
_ . RECEIVED Job: Winchester Short Form Date: Nov 09, 2004 Entire House '? / 6 2005 By: BGJ CITY OF REXBURG Project Info For: Kartchner Homes Rexberg, 0500102 SFR Karichner I Ionics Design I 1 • 6.r-.uu Htg Clg Infiltration Outside db (OF) -6 89 Method Simplified Inside db (OF) 72 72 Construction quality Average Design TD (OF) 78 17 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -24 HEATING EQUIPMENT Make BRYANT HEATIN Trade Bryant, Plus 90 Model 350MAV036080 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 93.1 AFUE 80000 Btuh 75000 Btuh 75 OF 1087 cfm 0.029 cfm/Btuh 0.40 in H2O COOLING EQUIPMENT Make Bryant Trade Cube 561 W Cond 561WP036-D Coil FG3AAA036+TDR Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 10 EER 22820 Btuh 9780 Btuh 32600 Btuh 1087 cfm 0.182 cfm/Btuh 0.40 in H2O 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) future bed 208 1792 143 53 26 fut bath 65 567 24 17 4 future family ro 660 5850 378 172 69 m bed 176 2745 558 81 102 Bonus 264 5502 712 162 130 bed 3 132 2588 525 76 95 bath 66 221 96 7 18 family room 319 3963 966 116 176 dining 192 3432 801 101 146 kitch 180 3594 660 106 120 m bath wic 169 1492 367 44 67 bed 2 156 2705 535 79 97 Mech 48 0 0 0 0 fut bed 195 2532 206 74 37 ....,...y.. �..., Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrtghtsoft Right Suite Residential 6.0.05 RSR40767 2005-Apr-0613:51:16 /ICE I'Minchester.up Calc= MJ8 Onentation= NW - Page 1 Entire House 3028 36983 5972 1087 1087 Other equip loads 3020 658 Equip. @ 0.94 RSM 6232 Latent cooling 0 1 T/1T A l G+ 1 7APY0 I AAA9 M-0113 f 4 A47 4 AQ7 I V I ^ %Jo JVLV 'TVVVJ VL JL 1 VV! 1 vvl Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,4ii., wrightS(:) t Right -Suite Residential 6.0.05 RSR40767 2005-Apr-0613:51:16 ACCA FAWinchester.rrp Calc = MJ8 Orientation = NW Page 2 Job: Winchester Date: Nov 09, 2004 By: BGJ Building Analysis Entire House Pro ect Information For: Kartchner Homes Rexberg, Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID US Elevation: 4' 41 ft Indoor temperature (°F) Design TO (N 72 78 50 72 17 50 Latitude: 440N Relative humidity (% Outdoor: Heating Cooling Moisture difference (Igr/Ib) 66.1 -23.8 Dry bulb (°F) -6 89 Infiltration: Daily range (°F) - 34 (H) Method Simplified Wet bulb (° ) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 "Heating Component Btuh/ft' Btuh % of load Walls 4.4 15267 38.2 Glazing 35.1 8541 21.4 Doors 30.4 1278 3.2 Ceilings 2.0 3354 8.4 Floors 1.8 3456 8.6 Infiltration 2.5 5087 12.7 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 3020 7.6 Adjustments 0 Total 40003 100.0 Component Btuh/ft2 Btuh % of load Walls 0.2 835 12.6 Glazing 9.0 2179 32.9 Doors 8.4 352 5.3 Ceilings 1.2 1935 29.2 Floors 0.1 117 1.8 Infiltration 0.3 554 8.4 Ducts 0 0.0 Ventilation 658 9.9 Internal gains 0 0.0 Blower 0 0.0 Adjustments 0 Total 6630 100.0 Overall U-value = 0.060 Btuh/ft'--°F Data entries checked. Glazn9 wnghtsoft RightSu@e Residential6.0.05RSR40767 2005-Apr-06 13:51 17 ACCA FAWinchester.np Calc= MJ8 Orientation= NW Page 1 Component Constructions Entire House For: Kanchner Homes Rehberg, Job: Winchester Date: Nov 09, 2004 By: BGJ Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 72 72 Elevation: 4741 ft Design TD (°F)) 78 17 Latitude: 440N Relative humldlty N 50 50 Outdoor: Heating Cooling Moisture difference (grllb) 66.1 -23.8 Dry bulb (°F) 6 89 Infiltration: Daily range (°F) - 34 (H) Method Simplified Wet bulb (°F) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain (R') (BtuM -F) (WP-F/Btuh) (Btuml) (Muh) (Btuw) (Btuh) Walls 12F-Obw: Wood stud frame, brick veneer, no board insulation, R-21 cavity insulation 15B11-Owc-10: Basement - W concrete, wood framing, interior finish, R-11 cavity, no board insulation, 10' Partitions 12C-Osw: Wood stud frame, siding or stucco, no board insulation, R-13 cavity insulation Windows 61 B: Vynal windows duel glazeds, clear Doors 11 DO: Wood door, solid core, no stone Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation n 20 0.065 21.0 5.07 100 0.36 7 ne 365 0.065 21.0 5.07 1851 0.36 133 e 20 0.065 21.0 5.07 100 0.36 7 se 496 0.065 21.0 5.07 2515 0.36 181 sw 420 0.065 21.0 5.07 2129 0.36 153 nw, 484 0.065 21.0 5.07 2454 0.36 176 all 1804 0.065 21.0 5.07 9148 0.36 657 ne 376 0.047 11.0 3.67 1378 0.00 0 se 304 0.047 11.0 1.93 587 0.00 0 sw 424 0.047 11.0 2.35 997 0.00 0 nw 288 0.047 11.0 3.67 1056 0.00 0 all 1392 0.047 11.0 2.89 4018 0.00 0 296 0.091 13.0 7.10 2101 0.60 178 n 9 0.450 0.0 35.1 322 7.65 70 ne 99 0.450 0.0 35.1 3475 7.65 757 ne 48 0.450 0.0 35.1 1685 7.65 367 e 9 0.450 0.0 35.1 322 7.65 70 sw 50 0.450 0.0 35.1 1755 7.65 382 nw 12 0.450 0.0 35.1 421 7.65 92 nw 16 0.450 0.0 35.1 562 7.65 122 all 243 0,450 0.0 35.1 8541 7.65 1862 sw 42 0.390 0.0 30.4 1278 8.38 352 1654 0,026 38.0 2.03 3354 1.17 1935 wrtghtsoft RightSuBe Residential6.005RSR40767 2005-Apr-0613:5117 ACCAF9Winchesternp Calc=MJ8 Orientation = NW Page 5loore 20P-30v: Vinyl floor over open crawllgarage, R-30 blanket insulation 264 0.035 30.0 2.73 721 0.17 21 A-20c: Carpeted basement floor, No insulation, 20' wide 1390 ' 0.027 0.0 1.73 2409 0.00 19CA 9cscp: Carpeted floor over tight enclosed crawl, R-11 wall, 246 0.049 19.0 1.32 326 0.29 R-19 blanket 46 71 1Ate�---- VVrjgJ tSO't Right -Suite Residential 6.0.05 RSR40767 2005-Apr-0613:51:17 fiC..CA F:1Winchester.rrp Calc = MJ8 Orientation = NW Page 2 Job: Winchester Date: Nov 09, 2004 By: BGJ Project Summary Entire House Project Information For: Kartchner Homes Rexberg, Notes: Design• • Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 OF Outside db 89 OF Inside db 72 OF Inside db 72 OF Design TD 78 OF Design TD 17 OF Daily range H Relative humidity 50 % Moisture difference -24 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 36983 Btuh Structure 5972 Btuh Ducts 0 cfm Ducts 0 Stuh Central vent (42 cfm) 3020 Btuh Central vent (42 cfm) 658 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40003 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 6232 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -480 Btuh Ducts 0 Btuh Heating Cooling Central vent (42 cfm) -570 Btuh Area (ft') 2782 2782 Equipment latent load 0 Btuh Volume (fP) 13232 13232 Air changes/hour 0.32 0.16 Equipment total load 6232 Btuh Equiv. AVF (cfm) 71 35 Req. total capacity at 0.70 SHR 0.7 ton Heating Equipment Summary Cooling Equipment Summary Make BRYANT HEATIN Make Bryant Trade Brryyant, Plus 90 Trade Cube 561 W Model 350MAV036080 Cond 561WP036-D Coil FG3AAA036+TDR Efficiency 93.1 AFUE Efficiency 10 EER Heating input 80000 Btuh Sensible cooling 22820 Btuh Heating output 75000 Btuh Latent cooling 9780 Btuh Temperature rise 75 OF Total cooling 32600 Btuh Actual air flow 1087 cfm Actual air flow 1087 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.182 cfm/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrghtsoft Right -Suite Rmidentia16.0.05 RSR40767 2005-Apr-0613:51:17 ACCK F:lwinchmtecrrp Calc=MJ8 Onentation = NW Pagel Main floor Job #: Winchester Performed by BGJ for: Kartchner Homes Rexberg 7„ Scale: 1 : 95 Page 1 Right -Suite Residential 6.0.05 RSR40767 2005-Apr-0613:51:51 F:1Winchester.rrp 16 1r Job M Winchester Performed by BGJ for: Kartchner Homes Rexberg Basement 53'-0" -1 Scale: 1 : 95 Page 2 Right -Suite Residential 6.0.05 RSR40767 2005-Apr-06 13:51:51 F:1Winchester.rrp bonus room Bon ® 162 Om Job M Winchester Performed by BGJ for: Kartchner Homes Rexberg Scale: 1 : 95 Page 3 Right -Suite Residential 6.0.05 RSR40767 2005-Apr-0613:51:51 FAWinchester.rrp Duct System Summary Entire House ProjectInformation For: Kartchner Homes Rexberg, External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual air flow Total effective length (TEL) Heating 0.40 in H2O 0.00 in H2O 0.40 in H2O 0.30 / 0.10 in H2O 0.132 in/100ft 1087 cfm 303 ft Job: Winchester Date: Nov 09, 2004 By: BGJ Cooling 0.40 in H2O 0.00 in H2O 0.40 in H2O 0.30 / 0.10 in H2O 0.132 in/100ft 1087 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) Rect Size (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk future bed h 1792 53 26 0.150 4 Ox 0 ShMt 33.0 170.0 st2A fut bath h 567 17 4 0.133 4 OxO ShMt 29.0 200.0 st26 future family ro h 5850 172 69 0.170 6 OxO ShMt 9.0 170.0 stl m bed o 558 81 102 0.158 5 Ox 0 ShMt 33.0 160.0 st2 Bonus h 5502 162 130 0.132 7 OxO ShMt 41.0 190.0 st4 bed 3 c 525 76 95 0.157 5 OxO ShMt 24.0 170.0 st2 bath c 96 7 18 0.160 4 Ox 0 ShMt 11.0 180.0 st2 family room a 966 116 176 0.151 7 Ox 0 ShMt 12.0 190.0 st2 dining c 801 101 146 0.173 6 Ox 0 ShMt 16.0 160.0 stl Hitch c 660 106 120 0.136 6 Ox 0 ShMt 24.0 200.0 stl B in bath wtc c 367 44 67 0.156 5 Ox 0 ShMt 26.0 170.0 st2A bed 2 c 535 79 97 0.147 5 OxO ShMt 38.0 170.0 st2A fut bed h 2532 74 37 0.147 5 Ox 0 ShMt 37.0 170.0 st2A Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk stl B Peak AVF 106 120 0.136 541 6 8 x 4 ShtMetl stl A st1A Peak AVF 267 250 0.132 802 8 8 x 6 ShtMetl st1 st1 Peak AVF 540 464 0.132 608 12 8 x 16 ShtMetl st2 Peak AVF 547 623 0.133 700 12 8 x 16 ShtMetl st2A Peak AVF 267 232 0.133 801 8 8 x 6 ShtMetl st2 st2B Peak AVF 17 4 0.133 150 4 8 x 2 ShtMetl st2A st4 Peak AVF 162 130 0.132 485 7 8 x 6 ShtMetl st1A Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) RectSize I (in) Stud/Joist Opening (in) Duct Mat! Trunk rb1 Ox0 1087 1087 72.0 0.132 615 18 Ox 0 1 ShMt