Loading...
HomeMy WebLinkAboutRESCHECK - 05-00102 - 362 Oaktrail Dr - New SFRREScheck Compliance Certificate 2000 I ECC RESchectSQ ware Version 3.3 Release le Data filename: Un itledrek CITY: Rexburg STATE_ Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family DATE: 04/05/05 DATE OF PLANS: P_pri15, 2005 PROJECT DESCRIPTION; Parade Home "Winchester' Oakbrook Subd. Lot:12 362 Oakbrook Dr Rexburg 11) 83440 DESTGNEi/CO-NTR1 CTOR: Kartchner How -as 3456 E. 17 Street Suii 210 Ammon City. LD 83406 COMPLIANCE: Passes Maximum UA = 426 'Four Home UA = 359 15,7% Better T_1:in Code (UA) Attic Ceiling: Flat Ceiling or Scissor Truss Attic -trusses: Wood Frame, 24" o .c, Window 1: Vinyl Frame0ouble Pane Ceiling 2; Flat Ceiling or Scissor Truss Wall 2: Wood Frames 16" o.c. Window 2: Vinyl Frame -Double Pane Door 1: Solid Door 2: Glass Basement Wail 1: Solid Concrete or Masonry Wall height: 9,0' Depth below ;rode: 70' Insulation death: 8.0' Window 3: Viml Frame:Double Pane Furnace 1: Formed Hni Air 9n AMTF 198-9 900/100'd 919-1 ti901 992 get+ Permit Number Checked By/Dale 0500102 SUR Karlchncr llunws RECEIVED APR / g 1005 CITY OF REXBURG Gross GIazing Area or Cavity Cont or Door Perimeter R-Value R-Valne U-Factor UA 345 40.0 0.0 10 631 24.0 0,0 32 12 0.490 6 1382 40.0 0.0 40 1456 24.0 0.0 67 141 0.490 69 37 0.200 7 33 0.490 16 1444 13.0 0,0 81 64 0,490 31 S310H UNH718VM-IMi Wa00!l1 900i-go-idV COlkeLIANCE STATEMENT: The proposed building design domcn'bed here is consistent with the building pl=, specifications. and other calculations submitted with the permit plication. The proposed building has born designed to meet the 2000 IECC requirements in RES heck i 3,5 del a (formerly NIBCehecA) and to comply with the mandatory requiren=is listed in the REScheckInspection ' Builder/Designer •C 196-� 90012OO'd 919-I V90L 991 get+ S3hOH UNHOISO-WOJ� W800:1i 900Z-90-idY REScheck Inspection Chehlsst 2000 IECC REScheckSoftwam Version 3.5 Release le DATE; 04/05/05 Bldg. Dept. Use ( Ceilings'. r [ ] I 1. Attic CdEng: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation ( Comments: [ ] I 2. CeiLng 2: Flat Ceiling or Scissor Truss. R-40.0 cavity insulation I Comments: ( ( Above -Grade Mails: J ; 1. Attic Trusses: 'Wood Frame. 2418 o x, R-24.0 cavity insulation ( Comments: [ j ( 2. Wail 2: Wood Frame:. 16" o.c.; R 24.0 cavity insulation Coimnent:s: I Basement Walls: j ( 1. Basement Wall 1: Solid Concrete or Masomy, 8.0' ht17.0' bg/8.0' insuL ( R-110 cavity insulation ( Commcn! S I Windows.- 1. Window 1: Vmyl Frame:Double Pane, U-factor. 0.490 ( For windows without labeled U-factors; describe features: ( # Panes",,, Frame Type_ _ _ _ _ _ _ -- Thermal Break?( ] 'Y'es [ j No ( commems: [ ] I 2. Window 2: Vinyl Frame:Double Pang. U factor. 0.490 For windows without labeled U factors; describe !features: ( ;,Uanes Frame Type Thermal Break? [ ] Yes [ ] No Comments: L 1 I 3. Window 3: Vinyl Frame:boubie Pane U factor. 0.490 j For windows without labeled U-fadom dcscn-be Features: i ;9 Pares Frame Type Thermal Break? [ ] Yes [ ] No I Comments; I I Doors: [ 1 J 1. Moor 1: Solid: U Factor: 0.200 J Cominews: [ 1 J 2. Door 2: ClaSs, U-factor: 0.490 j Comments: I Heating and Cooling Equipment; L ] I 1. Furnace 1: Forecd Hot Air. 90 AF'tJE or higher j Make and Model Number I Air Leakaga: I 1 I Jain! s, pencuidons_ and all other such openings in the building envelope that are sources of air I leakage must be scaled. [ ] ( Recessed lights must be 1) Type IC rated. or 2) installed inside an appropriate air -tight assembly I with a 0.5" clearance from combustible materials. If non-TC rated, the fixture must be installed with a ( 3" clearance from insulation. I 198-1 900/800'd 919-1 V801 991 95t+ SaiOH N3NH31SVA- O1 j W900:11 900Z-90-Jdy Vapor Retarder: Required on the warm -in -winter side of all non -vented framed ceilings; walls; and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacluror+s installation instructions. Materials and equipment must be identified so that compliance can be dctcrmine d. Manufacturer manuals for all installed heating and cooling cquipmeni and service water beating equipment must be provided. Insulation R values: glazing U-factors. and heating equipmend efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces mist be insulated to !t 5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All joints, seams_ and connections must be sacu re y fastened with welds; gaskets; mastics (adhesives). mastic -plus -embedded -fabric or taps. Duct tape is not permitted. ,exception: Continuously welded and looking -type longitudinal joints and seams on ducts operating at less Than 2 in. w.g. (500 Pa). Ducts shaiil be supported every 10 feet or in accordance with the manufactur&s instructions. Cooling ducts with oxterior insulation must be covered with a vapor retarder. Air filters are required in the rm m air System. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermost-rits are required for each separate HVAC system. A manual or automatic means to parially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Headw. Water heaters with vertical pipe risers mW have a heat trap on bath the inlet and owlet unless the water heater has an integral heat trap or is part of a circulating system. Trisuls tc arculatirg hot water pipes to the levels in Table 1. Circulating Hot Water 5yste uq: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an onloff heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a fm a ciock. Heating and Cooling Piping Lsalation: I j j HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. 196-d 900/VOO'd 919-1 V901 991 9£ti+ S30 S3NH3J V%-WOE J Ma00: I I 5002-9O-lay Table 1: Ninintum Insulation Thidmess for Circulating Hot Water Pipes ImIation Thiokn in incli Pi Svcs He ated dater Non-Cizculdiing R mouls Circulating Mains and Runouts Lem crature (F) iJ�a= ITv 1.5" to 2.4" Over Z" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2 Minimum Inbuladen 7'hkicness for BVAC Papas. Fluid Tamp. I.nsWattion ThUness in,_Inch_ es by- Pip-$ Sizes+,, ��..,�,,,, �iVtnQ-r System. Types � 2" Runouts 1" and Less 1.2.51 ..... 1 to 2- 2.5to 4 1fg systems Law Pressure/TempemL=e 201-250 1.0 1.5 1.5 2.0 Low Tempemnve 120-200 0.5 1.0 1.0 1.5 Stmm Condensate (far feed water) Any 1.0 1.0 1.5 2.0 Gaoling Systems Chilled Water. Red"rigmitt: 40-55 0.5 0.5 0,75 1.0 and Bribe Below 40 1.0 1.0 1.5 l .5 WO TES TO FMLD (Building Department Use Wy) 19H 900/900' d 919-1 tool 292 ask+ S3g0f1 83RH318V1-Waj � Es 10:11 900z-90-AV