HomeMy WebLinkAboutRESCHECK - 05-00102 - 362 Oaktrail Dr - New SFRREScheck Compliance Certificate
2000 I ECC
RESchectSQ ware Version 3.3 Release le
Data filename: Un itledrek
CITY: Rexburg
STATE_ Idaho
HDD: 8693
CONSTRUCTION TYPE: Single Family
DATE: 04/05/05
DATE OF PLANS: P_pri15, 2005
PROJECT DESCRIPTION;
Parade Home
"Winchester'
Oakbrook Subd.
Lot:12
362 Oakbrook Dr
Rexburg 11) 83440
DESTGNEi/CO-NTR1 CTOR:
Kartchner How -as
3456 E. 17 Street
Suii 210
Ammon City. LD 83406
COMPLIANCE: Passes
Maximum UA = 426
'Four Home UA = 359
15,7% Better T_1:in Code (UA)
Attic Ceiling: Flat Ceiling or Scissor Truss
Attic -trusses: Wood Frame, 24" o .c,
Window 1: Vinyl Frame0ouble Pane
Ceiling 2; Flat Ceiling or Scissor Truss
Wall 2: Wood Frames 16" o.c.
Window 2: Vinyl Frame -Double Pane
Door 1: Solid
Door 2: Glass
Basement Wail 1: Solid Concrete or Masonry
Wall height: 9,0'
Depth below ;rode: 70'
Insulation death: 8.0'
Window 3: Viml Frame:Double Pane
Furnace 1: Formed Hni Air 9n AMTF
198-9 900/100'd 919-1 ti901 992 get+
Permit Number
Checked By/Dale
0500102
SUR Karlchncr llunws
RECEIVED
APR / g 1005
CITY OF REXBURG
Gross
GIazing
Area or
Cavity
Cont
or Door
Perimeter R-Value
R-Valne
U-Factor
UA
345
40.0
0.0
10
631
24.0
0,0
32
12
0.490
6
1382
40.0
0.0
40
1456
24.0
0.0
67
141
0.490
69
37
0.200
7
33
0.490
16
1444
13.0
0,0
81
64 0,490 31
S310H UNH718VM-IMi Wa00!l1 900i-go-idV
COlkeLIANCE STATEMENT: The proposed building design domcn'bed here is consistent with the building pl=, specifications.
and other calculations submitted with the permit plication. The proposed building has born designed to meet the 2000 IECC
requirements in RES heck i 3,5 del a (formerly NIBCehecA) and to comply with the mandatory requiren=is listed in
the REScheckInspection '
Builder/Designer •C
196-� 90012OO'd 919-I V90L 991 get+ S3hOH UNHOISO-WOJ� W800:1i 900Z-90-idY
REScheck Inspection Chehlsst
2000 IECC
REScheckSoftwam Version 3.5 Release le
DATE; 04/05/05
Bldg.
Dept.
Use
( Ceilings'. r
[ ] I 1. Attic CdEng: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation
( Comments:
[ ] I 2. CeiLng 2: Flat Ceiling or Scissor Truss. R-40.0 cavity insulation
I Comments:
(
( Above -Grade Mails:
J ; 1. Attic Trusses: 'Wood Frame. 2418 o x, R-24.0 cavity insulation
( Comments:
[ j ( 2. Wail 2: Wood Frame:. 16" o.c.; R 24.0 cavity insulation
Coimnent:s:
I
Basement Walls:
j ( 1. Basement Wall 1: Solid Concrete or Masomy, 8.0' ht17.0' bg/8.0' insuL
( R-110 cavity insulation
( Commcn! S
I Windows.-
1. Window 1: Vmyl Frame:Double Pane, U-factor. 0.490
( For windows without labeled U-factors; describe features:
( # Panes",,, Frame Type_ _ _ _ _ _ _ -- Thermal Break?( ] 'Y'es [ j No
( commems:
[ ] I 2. Window 2: Vinyl Frame:Double Pang. U factor. 0.490
For windows without labeled U factors; describe !features:
( ;,Uanes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
L 1 I 3. Window 3: Vinyl Frame:boubie Pane U factor. 0.490
j For windows without labeled U-fadom dcscn-be Features:
i ;9 Pares Frame Type Thermal Break? [ ] Yes [ ] No
I Comments;
I
I Doors:
[ 1 J 1. Moor 1: Solid: U Factor: 0.200
J Cominews:
[ 1 J 2. Door 2: ClaSs, U-factor: 0.490
j Comments:
I Heating and Cooling Equipment;
L ] I 1. Furnace 1: Forecd Hot Air. 90 AF'tJE or higher
j Make and Model Number
I Air Leakaga:
I 1 I Jain! s, pencuidons_ and all other such openings in the building envelope that are sources of air
I leakage must be scaled.
[ ] ( Recessed lights must be 1) Type IC rated. or 2) installed inside an appropriate air -tight assembly
I with a 0.5" clearance from combustible materials. If non-TC rated, the fixture must be installed with a
( 3" clearance from insulation.
I
198-1 900/800'd 919-1 V801 991 95t+ SaiOH N3NH31SVA- O1 j W900:11 900Z-90-Jdy
Vapor Retarder:
Required on the warm -in -winter side of all non -vented framed ceilings; walls; and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacluror+s installation instructions.
Materials and equipment must be identified so that compliance can be dctcrmine d.
Manufacturer manuals for all installed heating and cooling cquipmeni and service water beating
equipment must be provided.
Insulation R values: glazing U-factors. and heating equipmend efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces mist be insulated to !t 5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams_ and connections must be sacu re y fastened with welds; gaskets; mastics
(adhesives). mastic -plus -embedded -fabric or taps. Duct tape is not permitted.
,exception: Continuously welded and looking -type longitudinal joints and seams on ducts
operating at less Than 2 in. w.g. (500 Pa).
Ducts shaiil be supported every 10 feet or in accordance with the manufactur&s instructions.
Cooling ducts with oxterior insulation must be covered with a vapor retarder.
Air filters are required in the rm m air System.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermost-rits are required for each separate HVAC system. A manual or automatic means to
parially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Headw.
Water heaters with vertical pipe risers mW have a heat trap on bath the inlet and owlet unless the
water heater has an integral heat trap or is part of a circulating system.
Trisuls tc arculatirg hot water pipes to the levels in Table 1.
Circulating Hot Water 5yste uq:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an onloff heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a fm a ciock.
Heating and Cooling Piping Lsalation:
I j j HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
levels in Table 2.
196-d 900/VOO'd 919-1 V901 991 9£ti+ S30 S3NH3J V%-WOE J Ma00: I I 5002-9O-lay
Table 1: Ninintum Insulation Thidmess for Circulating Hot Water Pipes
ImIation
Thiokn
in incli Pi
Svcs
He ated dater
Non-Cizculdiing
R mouls
Circulating Mains
and Runouts
Lem crature (F)
iJ�a=
ITv
1.5" to 2.4"
Over Z"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2 Minimum Inbuladen 7'hkicness for BVAC Papas.
Fluid Tamp.
I.nsWattion ThUness in,_Inch_ es by-
Pip-$ Sizes+,,
��..,�,,,,
�iVtnQ-r System. Types
�
2" Runouts
1" and Less
1.2.51
..... 1
to 2- 2.5to 4
1fg systems
Law Pressure/TempemL=e
201-250
1.0
1.5
1.5
2.0
Low Tempemnve
120-200
0.5
1.0
1.0
1.5
Stmm Condensate (far feed water)
Any
1.0
1.0
1.5
2.0
Gaoling Systems
Chilled Water. Red"rigmitt:
40-55
0.5
0.5
0,75
1.0
and Bribe
Below 40
1.0
1.0
1.5
l .5
WO TES TO FMLD (Building Department Use Wy)