INSPECTION TICKETS - 05-00101 - 649 Johnson St - New SFR
110 INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fire Inspection Request: Rec'd By Qy;e Date O/6 Req.By ,)AyPA Phone No. Project Permit No. D S 00 10 Address%'*f 01 'JL Lil�Sa v-� Inspection Type T1 -04 Day /Time Req. DL+ Inspector's Report j2f Res. ❑ Comm. INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPE OR-S ACTION ��A�PPROVED Tom" P ( 6. (FINAL) ACTION REQUIRED: _ ❑ DISAPPROVED ❑ NOT APPLICABLE ❑Y ❑N ❑NIA FINAL ❑ DID NOT INSPECT -- rrn;sk a(voye- i(ems. call bIWK Recl Acknowledged WM1ee � puce Copy YeNow - Job Copy Pk* - Impus" Copt F FIR C000 INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fire Inspection Request: Req. By L�:r1 Project Address 1>{1 Rec'd By Date b iV oS Phone No. i� i 3 —c55S Permit No. b>-Gl l01 Inspection Type t td i Day Mine Req. 10 � 11 (� I (_31l \nJI�11 I.IS�_ Inspector's Report ❑ Res. ❑ Comm. Y INSPECTED ITEMS CONFORM TO APPROVED DWGS []Y ❑ N ❑ N/A INSPECTOR'S ACTION ,j jAPPROVED [) DISAPPROVED Ll FINAL L] C.O. (FINAL) ❑ NOT APPLICABLE ❑ DID NOT INSPECT ACTION REQUIRED: Signed //�/ice lL� ReCt Acknowledged WIAe - Cpke Copy F-FIR C003 �lG�',l<5. Inspector YeNow - Job Cop F r* - Inspecim's Copy INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fire Inspection Request: Rec'd By Date 5 Req. By C1 � fit Phone No. Sl 0 " 0435 Projcc:l WeVX\ex56A S:),1ock v%i\siCn Pennit No. 65 OO l Address io Ltq InspectionType Day (rime Req. 51 G1 Inspector's Report ❑ Res. ❑ Comm. ()-K-- 4e:T av r- INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPECT 'S ACTION APPROVED El DISAPPROVED I] C.O. (FINAL) ❑ NOT APPLICABLE ACTION REQUIRED: DY El 0NIA 0 FINAL ❑ DID NOT INSPECT Rec't Acknowledged WMG - Office Copy F-FIR•CO03 Mow - Job Copy Ffaic - I upsdor's Copy INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fim Inspection Request: Rec'd By kk) Date it vo - Req. By Phone No. Prujccl Permit No. © CC I % Address Inspection Type -k Day /Time Req. V _ Inspector's Report Res. ❑ Comm. INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPECT R'S ACTION APPROVED [j DISAPPROVED 0 C.O. (FINAL) ❑ NOT APPLICABLE ACTION REQUIRED: Signed Rec't Acknowledged WMe - Office Copy F-FfR•0003 D Y ❑ N ❑ N/A L] FINAL ❑ DID NOT INSPECT Yleflow - Job Copy F%* - tnapedoft Copy INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fee Inspection Request: Rec'd By olo_Date y,?9 Ds- Req. By Phone No. Project 1_upUG/ss / Permit No. �S-G»/d/ Address _� 0 Inspection Type Day /Time Req. 6df�/ Inspector's Report Res. ❑ Comm. 0v_ INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPECFOR"S ACTION APPROVED UC.O. (FINAL) ACTION REQUIRED: El DISAPPROVED ❑ NOT APPLICABLE ❑Y ❑N QN/A U FINAL ❑ DID NOT INSPECT inspector ReCt Acknowledged WIMe - CnKe Copy YeRm . Job Copy Pik - Ilgimcia s Copy F-FIR C000 INSPEC�iON TICKET ❑ Bldg. Qf Plumb. ❑ Elect. ❑ Mech. ❑ Fire Inspection Request: Rec'd By V2 Date Req . By Phone No. T Prujcct •'^j49�ig1r CL Permit No. Address(,,00jej vsCjej GY�ISO Inspection Type lQ� lk Day crime Req. Inspector's Report 3 Res. ❑ Comm. INSPECTED ITE S CONFORM TO APPROVED DWGS INSPECT S ACTION PPROVED [j DISAPPROVED 0 C.O. (FINAL) ❑ NOT APPLICABLE ACTION REQUIRED: Signed Rec't n�Wledged White - Office Copy F•F(R•C003 [] Y ❑ N ❑ N/A 0 FINAL ❑ DID NOT INSPECT • Job Copy Pink - Inspector's Copp INSPECTION TICKET Bldg. ❑ Plumb. ❑ Elect. A Mech. ❑ Fire Inspection Request: Rec'd By Kl Date g Req. B Phone No. -:t) Projccl Pennit No.(", Address InspectionType ar Yr� Day /Time Req. Inspector's Report Res. ❑ Comm. 124 w olt l a1L 4 INSPECTED ITEMS CONFORM TO APPROVED DWGS 0 Y 0 N 0 N/A INSPE S ACTION APPROVED [j DISAPPROVED 0 FINAL (] C.O. (FINAL) ❑ NOT APPLICABLE 0 DID NOT INSPECT ACTION REQUIRED: Signed Inspector Rec't Acknowledged Whhe - dlke Copy Yelow - Job Copy P" Irgwfor'e Copy F FIR-CO03 INSPECTION TICKET ). Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fire Inspection Request: Rec'd By <=b� Date � Z3 Req. By Phone No. 3!-5 —o S�s6 Projcct_ C�4_ Zyo Perini( No. OS col 01 Address S�Y Inspection Type MAIAL_v� Day !Time Req. 1 - 0 ekv% Inspector's Report ❑ Res. ❑ Comm. 4''t�w 10 Al INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPECTOR'S ACTION /APPROVED Ej DISAPPROVED L7 C.O. (FINAL) ❑ NOT APPLICABLE ACTION REQUIRED: Signed Rec't Acknowledged White - 011ke Copy F•FIR-CO03 [J Y ❑ N [] NIA tj FINAL ❑ DID NOT INSPECT Yettow • Job Copy PM - h,Spedor's (.on INSPECTION TICKET U Bldg. ❑ Plumb. ❑ Elect. ❑ Mech. ❑ Fa Inspection Request: Rec'd By 9c, Date to I Z Req. By T� Q-11m Phone No. S13-65SS Project {;vA&.A ,x � Permit No. 05-00101 Address Vie-1 JDhCWn 5k(ee� Inspection Type Ctdrc,\fso Day (rime Req. Lo IZI IF 2.30 em Inspector's Report ❑ Res. ❑ Comm. �JP D Tans Lk l c� INSPECTED ITEMS CONFORM TO APPROVED DWGS INSPECTOR'S ACTION j_]APPROVED 0DISAPPROVED 0C.O.(FINAL) El NOT APPLICABLE ACTION REQUIRED: ❑Y nN ❑N/A O FINAL O DID NOT INSPECT ReCtAcknowh Wide - ofka Copy F FIFbCOD3 Yellow - Job Copy Pink Impodw's Copy FRAMING/MECH. CHECKLIST Date: Project: Job Address: 6Vy7 L/o,rs� Building Permit Number: 65 -a0 /d1 The following comments based on the 2003 edition of the International Residential Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state or local regulations. Exterior Concrete Slabs (3 1/2" min. thickness & 4" gravel base min.) R606.1 ,ZBraced Wall Panels (sheathing) (nail or staple - 6" o. c. at edges & 12" o. c. in field) Table 602.3(1) ,ZAdequate uplift control at floor line (sheathing split on plate or 1 %2 X 36" straps 4' o. c. mudsill to studs) ,Seismic hold-downs at garage panels <4' wide (APA narrow panel design if <2'8"), hold-downs must be on double stud or 3X with all nail holes filled. R602.10.4 Foundation waterproofing to finish gradeR406.1 ::"—Crawl space ventilation 1 sf per 150sf (w/ vapor barrier 1 sf per 1500sf) within 3' of comer R408.1-2 —Cripple Walls (over 4' sized as 2 story, under 14" must be solidly sheathed one side) R602.9 /Mud Sill (bolts in proper location, nuts tightened, 2"x2"x3/16" washers (conditional), pressure treated or redwood, joints blocked or under studs at wall and gaps grouted or shimmed) R403.1.6.1 / R602.11.1 Frame Floor Sheathing and nailing Typ. 3/4" T&G - 6" on edges & 12" in field (perpendicular to joist) Joist Spacing and Size (as per plans) Baring (1-1/2" min.) & Lapping (3" min. where joists lap over wall or beam) 7 ZNotching (depth-1/6 max., length-1/3 depth max., not in middle 1/3, ends- 1/4 depth max.) TJI-NO /Boring (1/3 "d" max, >2" of top or bottom or another hole or notch) TJI see chart Cantilevers- Blocking, reinforcement, span andspacing as per plans. Joists Under Load Bearing Partitions (shall be doubled as per Section 502.3.3, if plumbing space needed, the joists shall be blocked 4' o. c.) Girders and Beams (as per plans, nailed or mechanically connected to frame and proper bearing) /Joist Hangers (check location & nailed properly) _Draft Stop (required for over 1000 sq ft. of unusable space at floor/ceiling) /Basement Walls (pressure treated or redwood sill plate properly fastened to slab) -/ Stair Opening (as per plan & properly supported with hangers or walls) Stairs (check rise- 7 3/4" max., run-10" min., vari.- 3/8" max, width-3' min. & headroom- 6-8") Wall Layout (as per plans) _�terior Wall Stud Spacing (load bearing is same as exterior), 24" o.c. max.) _ZBearing Wall Window and Door Headers Nailing (edge /ends) Exterior Bearing Wall Stud Spacing - walls carrying roof load only' 2x4-16" o.c. 12' max 2x4-24" o.c. 10' max,- 2x6-16" o.c. 18' max,- 2x6-24" o.c. 16' max, one floor & roof: - 2x4 16" o.c. 10'max., two floors & roof: 2x4-12" max 10' (Fig 602.3.2.(1-3)) Double Top Plate Qoints lapped min. 2') or Single Top Plate (bearing Win 1" & adequately tied at joints by 3"x6" steel plates w/ 6 8d on nails each side) R602.3.2 Stud Notching (bearing 25% max.) Boring 40% max, 5/8" min. to edges (60% if doubled) Fire Blocking (roof space line at wall, concealed spaces & at studs over 10') Firewalls (between duplexes & garage/home) , £rewall penetrations - elec. boxes- rated, ducts — 26 gauge & not open to garage, door-20 minute rated min. Roof /Truss details (35# snow load and 90 mph winds) See truss details ,/Roof Trusses (spaced and braced as per manufacturer) Rafter and Truss Tie -Downs and hangers Rafters Lateral Support (block at bearing when exceeding 5 to 1 rule (2x12) _Roof Sheathing: Nailing ("H" clips w/ 7/16"), edges-6" o.c., Feld-12" o.c. /ttic Access (provide 22" x 30" min. access where clear height > 30") Roof Ventilation (standard 1 /150 or 1 /300 if 50 - 80% is 3' above eaves) Me hanical (Rough Plumbing Insp. Done? Manufacturer's installation instructions are with the appliance (IRC 106.1.2/M1307.1) Equipment gas shutoff valves in same room (FP exception) and within 6' of appliance (IFGC 409.5) Sediment Traps (if not built into appliance) at Furnace & W.H. (IFGC 408.4) �ct Supports and sealed metal - < 10' spacing & Flexible — < 4' max — (2" sag in 4') /,-/Clothes Dryer Ducts (solid metal ducts, no screws extending into duct & vent directly to outside) /eeDuct insulation ( insulation in non -conditioned Space) Room access 24" min width / Attic access clear opening 20x30 min (Under floor is 22x30)(IMC 306) --Pressure Regulators (access, vented, tee fitting each side) (IFGC 410) ZGas pipes not in ventilating or circulating air duct (IFGC 404.1) Metallic gas pipe bends are smooth & free from buckling, cracks, or other damage (IFGC 405.2) r Pressure Test: .�/• 5 psi _ min duration -- lb pressure drop Gas Pipe Material: CSST 0 ch40 MP opper Main Line ,&ft Diameter.L Branch Lines: Length ft To POD ft ft ft ft ft ft ft ft ft ft ft ft ft __C) 5-L;eA4 Diameter Appliance/BTU's (if known) FINAL INSPECTION CHECKLIST Date: 10.-6 Project: %Zuu� Job Address: (gyp ,/�„Fn�,,t �,z Building Permit Number: 0S 00lo, The following comments based on the 2000 edition of the International Residential Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state or local regulation. OUTSIDE x/"House Numbers (visible from the street) -,Grade (yard is sloped away from foundation) Zidewalk & Landscape Strip 6' wide (W/ 6" of granular borrow (hill 12")) --7' LS strip _ZFront Setback Coverage 60% min green Windows - Covers and Screens (shall be releasable or removable from the inside for egress Window Wells min. 24" clear (out and above) well Exterior Steps (7 3/4 " max. rise & 10" min. tread) / S/tairway Handrails 4 or more risers or over 30" (<4" max. spacing of uprights) Guardrails (provide if over 30" above floor/grade & 4" max sphere spacing for uprights) landings (36" x 36" min., (not req. at the top of the stair if a door does not swing over stairs) TThresholds 1 1/2" max. above floor or landing (7 3/4" max if door does not swing over landing) /Posts (required to be treated, redwood or cedar if in contact of concrete / earth) Roofing (no apparent leaks, installed properly and roofing as per plans) Masonry (lintels as per table 703.7. 1) Roof Ventilation (as per plans) INSIDE _Egress Doors (all egress doors must be able to open from inside without use of keys or tools) / Window Energy calc's: match actual window Safety Glazing provided in all doors, within 24" of door arc and below 60", & in tub enclosure Xathroom Ventilation (either operable window or fan that vents directly to outside) .Sinks, Bathtubs and Showers (check for caulking, operation and leaks) _ZSstairway Illumination (switch at top and bottom) Stairs (7 3/4"max. riser, 10"' min. tread, (nosing 3/4"to 1 1/4" with solid risers) Handrails Cont (34" to 38", 1 1/2" to wall, and grip 1 1/4" to 2" dia. upright < 4",triangular space 6" max) .Guardrails 36" high and continuous, Req'd 30" or more above grade or floor(, uprights 4" sphere max spacing, triangular space 6" sphere max spacing) .Garage (Dry walled and taped, firewall penetrations and electrical boxes, door to house 20 min. rated, ducts penetrating firewall must be 26 gauge min. & not open to garage) S t-Egress Windows (clear 20" width and 24" height, 5.7 sf min. opening with 44" max. sill height) _Smoke Detectors (in each sleeping room, outside in immediate vicinity and on each story/basement- split levels (w/o doors), only on upper floor --all interconnected without a disconnecting switch) ' Foam Plastic (meets requirement of R318) Water Heater Anchorage as over 4' with flex water conn. shall be anchored or strapped to building) Water Heater Vent (check air flow with return in finished basement) Clothes Dryer Ducts (solid metal ducts, no screws in duct & vent directly to outside) /Duct Supports (metal ducts supported 10' min spacing & non metal as per manuf. installation instr.) _Duct Insulation (duct in non conditioned areas shall be insulated) _ZGas Line Supports spacing 10' for up to 3/4", 12' for over 1" and 6' for tubing up to 1 1/2"