HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 05-00101 - 649 Johnson St - New SFRCGenerated by REScheck Package Generator
�(J Compliance Certificate
Energy Code:
Location:
Construction Type:
Window4o-Wall Ratio:
Heating Degree Days:
Report Date:
1993 MEC
Rexburg, Idaho
Single Family
0.15
8693
Date of Plains: April 6, 2005
Project Information:
Rexburg Idaho 83440
Project Notes:
Builder Information:
Donald Ruud
Ruud Enterprise, L.L.C.
16 Mill Race Road
208-313-0555
OS cn�o
Pe i Number
y
Checked By/Date
Ceiling:
49.0
0.0
Wall:
19.0
0.0
Basement;
15.0
0.0
Window:
0.350
Door:
0.350
Floor.
19.0
0.0
Slab -on -Grade:, Insulation Depth: 4.0'
9.0
Furnace:: 80 AFUE
Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and
other calmlations submitted with the pemrit application. The proposed building has been designed to meet the 1993 MEC
rT
nfs in REScheck Package Generator and to comply with the mandatory requirements listed in the REScheck
JCh 1'' t.
Builde r C pany Name Da D
Page 1
AIL
CGenerated by REScheck Package Generator
�jr REScheck Inspection Checklist
Ceilings:
Ceiling: , R-49.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall:, R-19.0 cavity insulation
Comments:
Basement Walls:
❑ Basement: , 8.0' htf5.0' bg18.0' insul, R-15.0 cavity insulation
Comments:
Windows:
Wmdow: , U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes �- Frame Type ll..r ,f f Thermal Break? Yes No
Comments:
Doors:
J Door: , U-factor: 0.350
Comments: Front door exempt
Floors:
LI Floor: , R-19.0 cavity insulation
Comments:
❑ Slab-0rFGrade: , 4.9 insulation depth, R-9.0 continuous insulation
Comments: Unheated 48 inch depth
Slab insulation to extend down from the top of the slab to at least 4.0 fL OR down to at least the bottom of the slab then
horizontally for a total distance of 4.0 ft.
Heating and Cooling Equipment:
U Furnace:: 80 AFUE or higher
Make and Model Number:
Air Leakage:
0 Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
• Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture most be installed with a 3" dearance from insulation.
Vapor Retarder.
❑ Required on the wane -in -winter side of all ran -vented framed ceilings, walls, and floors.
Materials Identification:
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Page 2
Duct insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous duds. Duct tape
is not permitted.
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 120OF or chilled fluids below 55OF must be insulated to the levels in Table 2.
'Rage 3
0
Table 1: Minimum Insulation Thicimess for Circulating Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature (OF)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thic/mess for HVAC Pipes. Hot Water Pipes
Fluid Temp.
Piping System Types
Range(OF)
Heating Systems
Low Pressure/Temperature
201 250
Low Temperature
120-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Rehigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
Insulation Thickness In Inches by Pipe Sizes
2" Runouts
1" and Less
1.25" to 2.0"
2.5" to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
Page 4