HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE - 05-00101 - 649 Johnson St - New SFRCGenerated by REScheck Package Generator �(J Compliance Certificate Energy Code: Location: Construction Type: Window4o-Wall Ratio: Heating Degree Days: Report Date: 1993 MEC Rexburg, Idaho Single Family 0.15 8693 Date of Plains: April 6, 2005 Project Information: Rexburg Idaho 83440 Project Notes: Builder Information: Donald Ruud Ruud Enterprise, L.L.C. 16 Mill Race Road 208-313-0555 OS cn�o Pe i Number y Checked By/Date Ceiling: 49.0 0.0 Wall: 19.0 0.0 Basement; 15.0 0.0 Window: 0.350 Door: 0.350 Floor. 19.0 0.0 Slab -on -Grade:, Insulation Depth: 4.0' 9.0 Furnace:: 80 AFUE Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calmlations submitted with the pemrit application. The proposed building has been designed to meet the 1993 MEC rT nfs in REScheck Package Generator and to comply with the mandatory requirements listed in the REScheck JCh 1'' t. Builde r C pany Name Da D Page 1 AIL CGenerated by REScheck Package Generator �jr REScheck Inspection Checklist Ceilings: Ceiling: , R-49.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall:, R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement: , 8.0' htf5.0' bg18.0' insul, R-15.0 cavity insulation Comments: Windows: Wmdow: , U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes �- Frame Type ll..r ,f f Thermal Break? Yes No Comments: Doors: J Door: , U-factor: 0.350 Comments: Front door exempt Floors: LI Floor: , R-19.0 cavity insulation Comments: ❑ Slab-0rFGrade: , 4.9 insulation depth, R-9.0 continuous insulation Comments: Unheated 48 inch depth Slab insulation to extend down from the top of the slab to at least 4.0 fL OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 ft. Heating and Cooling Equipment: U Furnace:: 80 AFUE or higher Make and Model Number: Air Leakage: 0 Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. • Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture most be installed with a 3" dearance from insulation. Vapor Retarder. ❑ Required on the wane -in -winter side of all ran -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Page 2 Duct insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: ❑ All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous duds. Duct tape is not permitted. ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 120OF or chilled fluids below 55OF must be insulated to the levels in Table 2. 'Rage 3 0 Table 1: Minimum Insulation Thicimess for Circulating Hot Water Pipes Insulation Thickness In Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (OF) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thic/mess for HVAC Pipes. Hot Water Pipes Fluid Temp. Piping System Types Range(OF) Heating Systems Low Pressure/Temperature 201 250 Low Temperature 120-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Rehigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness In Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 Page 4