Loading...
HomeMy WebLinkAboutRESCHECK - 05-00087 - 637 Autumn Ct - New SFRREScheck Compliance Certificate 2000 IECC RES checkSoftware Version 3.5 Release 1 b Data filename: C:1Frogram FileslChecklRESchecklcall.rck T'IT'LE; Jensen Batt CITY: Rexburg STATE:,fdabo II+ 8693 CONSTRUCTION TYPE: Single Family DATE: asr1-3ios DATE OF PLANS: 411145 PROJECT nyFoxMAT-ION: Jensen /coil COMPANY INFORMATION: Brett Jensen Construction Inc. COMPLIANCE: Passes Maximum UA = 596 Your Hume UA = 477 24.{]°lo Better Than Cade (UA) e�S— e�yro 6 7 Permit Number Checked By'Date Gross Glazing Area or Cavity Cont. or Door Perimeter --Value R -Val -Factor UA Ceiling I Flat Ceiling or Scissor Truss2597 45.0 0.0 Wall I '.mood Frame, 16 11 O.C. 2735 2 2 Window 1: Vinylftu%l Pane with Low -E 4 0." 0.340 137 Door 1 -1 Solid 110 0.340 7 Basement Wall 1 Solid Concrete or Masonry Wall height: 8.01 736 19.0 0.0 32 Depth below grade: .t6' Insulation depth:8.0' Basement Wall 2-. Solid Concrete or Masonry 1486 19.0 0.0 74 Wall height: 4.0 Depth below grade-. 3.67 Insulation depth; 4.0' Air Conditioner 1- Electric Central Air, 10 SEER Frac : Forced. Hot Air, 90 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building pians, speczfi�ations, and other calculations submitted with the permitt application. The proposed bu�ldi�g has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly 1V(ECcdxecl� and ifl comply with the mandatory requirements fisted in the REScheckInspectzan Checklist. Date REScheck Inspection Checklist 200.0 IECC UScheck5oftware Version 3.5 Release ib DATE: 06/23/05 TITLE: Jensen / Brett Brag. � Dept. � Use � Ceilings: [ J � 1. ceiling Z: Flat Ceiling or Scissor Truss, R-45. 4] cavity ins ulaixon � Comments.- Above-Grade omments:Above-Grade Walls: 1. Wall I � Wood Frame, lb" ox.,, R-21.0 cavity itisulation J Comurxa.ents: � Basement Wails: � ] i 1. Basement Wall 1: Sapid Concrete or Masonry, 8.0' htl7.6' bg18,,O' insul, j R-19.4 cavity insulation � Comments: [ ] ! 2. Basement Wall 2: Solid Concrete or Masonry, 4.0' ht13.6' bg14.Q` insul, R- ]. 9.0 c�viiy insulation � Comments: � Windows; f I { i . Window l : Vinyl Frame:Double Pane with Low -E, U -factor: 0.340 � For windows without labeled U -factors, describe features:. � # .Panes Frame Type Thermal Break? [ 1 Yes [ j No Comments-- f J Doors. [ ] j 1. Ivor 1: Solid, U -factor: 0.340 � Comments: � heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 10 SEER or higher � Make and Madel Number [ ] j 2. Furnace 2: Forced Hod Air, 90 AFUE or higher � Make and Model Number � Air Leakage: Joints, pettetrations, and all other such openings in the building envelope that are soul -cep of a.ir � leakage must be sealed. [ ] � Recessed lights must he 1) Type IC rated., or 2) installed inside an appropriate air -tight assembly � with a 0.5" clearance from combustible materials. If non -IC rued, the fixture must be installed with a � 3" clearance from insulation. � Vapor Retarder: [ ] � Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. f � Materials Identification: [ ] � Materials and equipment must be installed in accordance with the manufacturer's installation instruciions. � ] � Materials and equipment must be idenfified so that compliance can be determined. ] � Manufacturer manuals for all installed heating and cooing equipment and service water heating equipment must be provided. { ] � Insulation R -values, glazing U -factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] � Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] � All joints, seams,, and connections must be securely fastened with welds gaskets, mastics (adhesives), mastic-plus-embeddedis inot permitted. -fabric, or tapes. Duct tape Exception.- Continuously welded and locking -type longitudinaljoints and seams on ducts operating at less than 2 in. w.g. (500 Pa).[ � � Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] J Cooling ducts with exterior insulation mist be covered with a vapor retarder. [ ] � Air filters are required in the return air system. [ ] j The HVAC system must provide a means for balancing air and water systems. Temperature Controls: � � J Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or coaling input to each zone or floor shall be provided. Service Water Heating: � ] � Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral beat trap or is part of a circulating system. [ ] � Insulate circulating hot water pipes to the levels M' Table 1. Circulating Hot Water Systems: [ ] p Insulate CJ*_rculat'M_g hot water pipes to the levels in Table 1. Swimming Pools: [ J j 0 All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. -Pool pumps require a time clock. Heating and Cooling Piping Insolation; [ ] � HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table I: Minimum Insulation Thicknessfor Circulating Insulation Inickness in Inches by Pipe Sizes Heated Water Temperature F) 170-180 140-160 goo -13o Non-Circulatin Up to I a.5 0.5 0.5 Runouts Circulating Mat'ns and Runouts 1.511 L 2.011 1. Over " 1 1. Table 2= Minimums Insulation Thickness}or HVAC Pipes. Fluid Temp_ Insulation thickness in Inches Piping System Tes Ran e F -- Heating Systems Law Pressure/Temperature Low Temperature Steam Condensate (dor feed. water) Coaling Systems Chilled Water, Refrigerant, and Brine " nut I" and Less Ploe Sizes 201-250 1.0 1.5 1.5 . 120-200 0.5 1.0 1.0 1. Any Lo 1.0 1.5 2.0 40-55 0.5 0J 0.75 1. Below 40 .1.0 1.0 1.5 1.51 NATES TO FIELD (Building Department Use Only) REScheck Compliance Certificate 1995 MEC RES checkSOftware Version 3.5 Release I b Data filename: C:\Program Files\Check\RESchecklSpec 14.rck TITLE: Jensen ! Brett CITY: Rexburg STATE,-, Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family DATE: 03/14!05 DATE OF PLANS: 3/12/05 PROJFECT INFORMATION: Jensen Eagle wood seliars COMPANY INFORMATION* Bret Jensen Construction Inc. COMPLIANCE,-- Passes Maximum UA = 605 Your Home UA = 447 26. 1%Better Than Code (UA) Ceiling 1 - Flat Ceilm*,a; or Scissor Truss Wali 1: Wood Frame, 16" O.Q. Windavv 1: Vinyl Frwne:Double Pane with Law --,E Door 1: Solid Ficor L. A1l•Vood JoistiTruss:over Unconditioned Space CmW1 1: Solid Concrete or Masonry Wall height: 4,2r Depth below grade: 3.0' Insulation depth-. 3.0' Furnace 1: Forced Hot Au, 85 AFtJE Air Conditioner 1,', ElecUic Central A' 10 10SEER Permit Nmber Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R -Value R -Value U-1actor UA 2597' 45.0 0.0 70 1,512 21.0 21.0 32 A03 4.340 137 110 0.340 37 2597 25.0 25.0 49 1512 0.0 19.0 122 COMPLIANCE STATEMENT: Thi proposed building design described here is �ansist�n� with the bu��ding plans, specifications, and other calculations submitted with the permit application. The proposed build"M g has been designed to meet the 1995 NMCrequirements m' RESclieckVersian 3.5 Re1ease l b (formerly MECcheck and to comply with the mandatory requirements fiested in the RE5checklnspection Checklist. Buiflder/De,sigmer date REScheck Inspection Checklist 1995 MEC RES checksoftware Version 3.5 Release I b DATE: 03!14/05 TITLE: Jensen Bre Bldg. I Dept. Use � I Ceilings: [ � � 1. Ceiling 1: Fiat Ceiling or Scissor Truss, R-45,0 cavity irtsu}.ation � Comments& I Above,. -Grade Walls: f Wall 1: 'V4�ood Frame, 1611 o.c., R-2.1.0 cavity + R..2 1.O cantinuous irnsulation j Comments-. I j windows: [ � � 1. Window I Vinyl Frame:Double Pane with Low -E, U -factor: U.340 � For windows without labeled U -Victors, describe features: j # Pangs Frame Type Thermal Break? des [ ) No � Comments.6.6 i j Doors: Door 1:Solid,, U-Lfactor: 0,340 Conunents: Floors: I . Floor 1:,All-'Wood Joist/Truss #over Unconditioned Space, � R-25,0 cavity + R-25.4 continuous insulation � Comments: � Crawl Space Walls,, I. Crawl 1: Solid Concrete or Masonry, 4.2' bt/3.0'bg/3.0' insul, � R- 19.0 continuous insulation � comments: � Applies to walls o€unventilated crawl spares. 1 � Heating and Cooling Equipment..4L ( � � 1. Furnace 1: Forced Hod Airy 85 AFUE or higher ( Make and Model Number 2. Aff'o Condit*oner I - electric Central Air, 10 SEER or higher � Make and Madel Number Air Leakage: [ � j Joints, pene=ions, and all other such openings ire the building envelope that are sources of air j leakage must b;e seated, � ] j Recessed lights must be 1) Tye IC rated, or 2) installed inside an appropriate air -fight a��sembly j with a 0_5" cleamnce from combustible materials. if non -IC rated, the fixture must be installed with a j 3" ,�.tearan�e from insulation. i � Vapor Retarder: ] J Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. 1 { Materinis Idea tifiration : [ � � Materials and equipment mush he identifiedso that compliance can be determined. [ � � Manufacturer manuals fourinani stalled heating and cooling �c�u�pxne�t and se��ce �va�e� heating � equiprner�t must be provided. Insulafion R. -values, glazing U*factors, and heading equipment efficiency must be clearly marked on � the building plans or specifications. I � Duct Insulation: � ] j Ekuctsm"* unconditioned spaces must be insulated to R-5. � Ducts outside the buiIding must be insulated to R-$.0. � Duct Construction. All ducts must be sealed with manic and fibrous backing tape. Pressure -sensitive ape may be used � for fibrous ducts. Duct taps is not permitted. � ] � The HVAC system must provide a meas for balancing air and water systems. � Temperature Controls: ] f Thermostats are required for each separate HVAC system. A manual or automatic means to � partially restrict or shut off the heating and/or cooling input to each ,gone or floor shill be provided. j Ciarcula#�ng Hat Water Systems: � ] � Insulate circulating hot water pipes to the levels in Table 1. j Swimming Pools: All heated SWiri1mll1ppDlS must have an OI]IOff heater switch and require S cover Li.RleSS over 20% � of the heading energy is from non-depletable sources, fool pumps require ac time clock. � Heating and Coving piping insulation* [ ] � HVAC piping conveying fluids shove 120 T or chaIied fluids below 55 �F must be insulated to the � levels in Table 2. Table 1: Afinhmm Ii7sulation jrfilckniessforr Cirejulating flW IF afer Pipes. tnsu�araan � � ic�cness in inches by. Lpe Sims Heated WaterNI3R-GU�afin2 Rw outs A �,,..,...�.. TgmPeratwe.(F) 170-180 i40 -I6[} 100-130 vpto l " 0.5 0.5 0.5 Up to 1.25OWN" 1.0 0.5 0:.5 Table 2: minimum Insudajion Thicknm far )TVA C pipes. Fluid Temp. �i in S stern TypesIn MPMrRae(Fj Heating Systems Low Pressure/Temperature Low Temperature Steam condensate (for feed water) C0011'ag Systems Chided Water, Refrigerant, and Brine .+�g .rauuau GUILLIIVLLW 1.5" to 2.0" Over 2" 1.5 2.0 1.0 1.5 0.5 1.0 Insulation Thickness in Inches by Pi Sizes 2 " nouts I " and Less 1.2 5 11 t # -to 4" 201.4-250 I.0 1.5 1.5 2.0 ]20-200 0.5 E.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 aass 0.5 os 0.75 Lo Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use, Only)