Loading...
HomeMy WebLinkAboutSTRUCTURAL ENGINEERS - 05-00027 - 366 Talon Dr - New SFRTelephone: (208) 523-6918 ba G & S Structural Engineers 1600 John Adams Parkway Suite 200 Idaho Falls, ID 83401 E-mail: gs@dataway.net Tony Jenks .Teaks Brothers Construction and Remodeling 562. Legacy Lane Rexburg, II] 83440 Re: New Residence 36b Talon Drive Rexburg, Idaho Dear Mr, Seeks, Fax: (208) 523-6922 March 17, 2005 #05097 This letter is to Onfoi-n-1 you that G&S Structural Engineers performed an evaluation of the exterior perimeter walls located at the family room and the adjacent dining room and bedroorn of the above referenced residence. The wars have been evaluated based upon the 20(33 International Building bode (IBC) with a 90 -MPH wind speed, exposure C. and seismic design category D, using 35 psf ground snow load and 15 psf roof dead load. Reasonable professional effort has been made to comply with other codes and regulations in effect at the time of the review, The following items are identified as a result of the wall evaluation: I . The wall is to be constructed of 2x6 wall studs spaced at 24 inch centers. The studs are to be Doug-Fidr-Larch.) construction Grade or better, 2. The walk shad be sheathed in accordance with the attached wall schedule. 3. Two Simpson HDQS-SDS3 hold downs shad be added as shown on the attached red line plan. 4. Window openings shall be reinforced with a minimum of 3 studs on each side. 5. Girder Trusses GR02 and GR03. shown in the BMC truss layout package, shall be connected to the wallswith Simpson DSC drag strut connectors. 6. Girder Trusses GR02 and GR03 shall be design to resist a 4360 pounds of lateral force. 7. Roof sheathing shall be attached to Girder Trusses GR02 and GR03 with 8d nails spayed at 4 inch centers. At this time, G&S will not be performing any construction observation. Included with this letter are a redline markup of the main floor plan, a girder truss detail markup and a wall schedule. This letter and the evaluation apply only to the -walls mentioned above and do not cover any other framing or structural components of the house, nor mechanical, electrical or architectural 0 zea�ures. Due to the limited 'involvement and lack of control over both the drawings and the coi�struc�ion, G&S Structural Engineers is limiting our liability to $3 000.00 If these are any questions or if I can be of further assistance please don't hesitate to call, Sincerely, Kendall Phillips, P. E. .0 ;lu 31 - EZ O. -F I 0 4(y- 0 1 CT -b -00 I i B1 2093-4 Truss T Type jF TRUSS BMC WET (IDAHO FALLS), IDAHO FALLS, ID 8 1 UZ.s c - '- 7-2-4 -- aty lPly ��..... 2 %J%io Reference c tional - 100 s Sep 17 2004 MiTek Industries, Inc_ Tue Mar 15 09.-47-56 2005 Page 1 r 0-- 14-4-8 3-7- `- -7- .7 5x15 PA 112D R le: am -=I Pinter r)ff��+.e f �- LOADING (pso TOLL 35.0 TCDL 7.0 BOLL 0.0 BCCL 7-0 i 1 SPACING -0-0 Flates Increase 1.1 Lumber Increase 1,1 Rep Stress 1 ncr N Code II2000/Ah119 LUMBER TOP CHORD 2 X 4 SPF 165OF 1.6,E BCT CHORD 1.5 X 9.5 LSL Truss Grade VVEBS 2 X 4 SPF Stud/ td *Except* '1 2 X 4 SPF 1OI= 1,6E BIZACIN TO P CH ORD Shea.th ed of 5-9-14 oc purlins. BOT H O D Rigid cei1Jng directly appiied c 1 G-0-0 oo -bracing. REACTIONS (lb/,size) F = 5804/0-7-1 B 3611/0-7-12 Max Horz B 2 (load case 4) Max uplift F _ -29-19 (l.d case 6) B - -1 9 10(1oad case 5) FORCES (1b) Maximum Compressionimaximum Tension TOP CHORD A-E = 0197 11defl -428312266 D -4574/2527 D -E = -4551/2515 F - F = -6993/3561 BCT CHORD 18 B- I = -1590/2851 H-1 = -1590/2851 H -i = -2383/4710 J = -2383/4710 G -K = -2393/4710 G -L = -238314710 F -L = -2383/4710 WEBS -t = 8570 -H = -363688 D -H _ -342415975 E -H - -2160/1114 E- -1505/3117 TC 0.49 BC 0.33 WB 0.94 (Mathx). NOTES 1)2 -ply truss to be connected together with 0.1 31"x3' Na[ls as follows. Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 0c, Bottom chords connected as follows: 1.5 X 9,5 - 4 roe's at 0-4-0 m Webs connected as follows: 2 X 4 - 1 row at 0-9-0 . All loads are considered" equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CSA E($) section. Ply to ply nneot[ons have been provided to distribute only loads noted as (F) or (.13), unless otherwise indicated. 3) Unbalanced roof Ilya loads have been considered for this design, 4) Wind: ASCE 7-98; 0mph; hi b ; T C L;--4. p sf, E C L=4.2psf; Category 11, Exp C, enclosed; MWFRS gable end zone cantilever Cott and right exposed porch left and right exposed: Lumber D L=1.33 plate inip -L=1.33. This truss has been d .igned for a 10.0 psf bottom chard live load non nuLirrent with any other live loads. Provide mechanical connection (by others) of truss t0 bearing plate capable of withstanding 291 Ib uplift at joint F and 1'910 Ib uplift at joint B_ 7) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 48471b down and 29501b up at -1-8, and 1 8 1b down and 641lb Grp at 10-0-12, and 15831b down and 617Eb up at 12-0-12 -1 on bo om chord. The design/selection of such special connection device(s) i the responsibility of others. LOAD GASES) Standard 1) I egufar: Lumber lei ease=1.15, plate Increase=115 Uniform Loads (p1 Vert. A - D=-84, 4, -F 4, B-17=-14 Concentrated Loads (lb) Fort: d=- 7(F) K=-158 3(F) L=-1 583(F) -- DEFL in (10c) 11defl Lid Vert(LL) -0,07 -H X 9 9 9 240 Vert(TL) -0.10 -H >099 18 Horz(TL) 0.01 F n/a n1a US 7/ � `QTS 3� -73 a e. � 1 0-1-8 sr�ale '1- PLATES GRIP Ml 120 1871144 Weight' 229 Ib s F__7 21q pte- qc_ f,�' IAII (SEE FRAM&'C-_, PLAN' FOR SHEAR WALL HOLDONN5) A 3 ==;=;; --�WL (SEE APFFOPRIATE SEGTIONS FOR BOTTOM NAILIN61 MAR< ISTUDS MALL (I} 2xb 241[ O.G. SILL PLATE /BOTTOM PLATE OR E301 -TING) ANC,HOR 2x2x3/16 PLATE V4ALL TOP PLATE -7/16 (7)1 NA I L I N r-,? 150LTN A H E R 5 BLOGKIN6 DETA I L APA RATED (0--1 51 (P x 2 1/2 M I Nj (5) (4) (5) BREATH 16 Ep6ES '11- NTFRMED.Il _ 5/8 11 (p 5x 21-oll ars. -711 EED :2 x6 a PANEL JT. (CC41) BOTH 51DIES @ 61, C.G. I (1) USE C,0N5TRlUC-,T10N GRADE DCUC-_-;LA5 FIR. (2) USE PRESSURE TREATED HOOD NHEN lNc_-/0NTACT NITH CONCRETF. (3) USE A30-7 TEEL. DO NOT REGESS NUT ANE) VIASHER INT1L PLATE. MINIMUM 2 ANCHOR BOLTS FER PIEGE. LOGATE ANCHOR E30LTS 10 11 FROM EACH END OF 'IE E. GONTRACTOR MAY, U!5E 51IMPSONSET H 167 STRENOTH EPDX"-r hl 6'' MIN. E1 ED. IN LIEU OF ANGHOR BOLTS. USE THREADED ROD N/ SAME DIAMETER SPAGINC:7 AS ANGHOR F30LT. 1 (4) USE A36 STEEL. DO NOT REGESS INTO 5ILL PLATE. ILTE HASHERS ARE NOT REOUIRED , U STANDARD lIASHER5. (5) AT BEARIN6 N.LL 5 (E3N) ONLY, BLING MAS BE ELIMINATED IF HALL SHEATHINe-2 15 APDL IF -D. THERE TOP PLATE 1!5 CUT OR D15GONTINIJOUL; STRAF A(,'RCS!5 BREA< NITH SISON MST3_7 STRAIN. (1) SHE^THIN6 TO BE PL-r�00P OR OSE3. SET IGAL OR HORIZONTAL ORIENTATION.) PRO\/I:DE BLOGKIN6 AT ALL UNSUFFORTED PANEL E 5 FOR NAILING, 111CLUDIN6 PANEL E 5 AE30VE AND BELON OPENIN65. (b) NAIL5 SHALL BE 15TA667E.EI AT PANEL JOINTS AND SILL PLATE EDGES. PANEL JOINTHALL BE OFFSET TO FALL ON DIFFERENT FRAMIN6.7 MEMBERS. FLOOR OR ROOF LINE 41-0" MIN. LAP lbd NAI[ -5 (g 4" STAGGERED 41 DOUBLE TOP PLATE GHORD MEMBER J015T SPAC,,E L=AF 1 --FL Coe -OF TOF L A 6 1 5 STRU6TURAL ENC"INEERTIF LE; 600 JOHN APAH5 PrKIAY', 5UITE 200 IDAHO FALLS,![). 8340I,(_20b)523-6ql8 366 TALON DRIVE aF?,Q_JECT No. 0150cl-7 DATE: SHEET No, R.EXBU,RG I S 1"AC AMERICKS FANVULYCONWLINTY March 21, 2005 Permit Number: 05 00-027 Project Name: Project Type: Review Action SFR Single Family Residential _MW1 19 EMain St. Review Item Actions Re 1red for Approval uildincl Department review Complies with approved Site Plan Review Exiting Review Mechanical Review Height and Area Review Structural Review Energy Conservation Compliance Review Interior Environment Parcel #'s RPREGLWO020030 Need Mech info and licience Need plumbing sig & licience - cannot use journey min as signature Need engineering on entire back waft and lower garage (prestressed panels and their support)• Truss details also required before framing. REScheck errors. Glass doors not included, No Bonus roam floor insulation shown. Total wall area tow (either framed portion or concrete wall). Insulation approximately R-88 in attic, R- 41 in framed walls, and R--30 at basement foundation walls_ 24" Clearance in front of upstairs shower door. What is bonus roam to be used for? Rexburg, Idaho $3440 Phone (208) 359-3020 Fax (20$) 359-3022 _ Approved 03/21/2005 03121/2005 03121/2005 03/21/2005 Feb OB 05 10:34a Lo(i 1-208-466-5341 P.1 F�41 BOX 3185 Umpa, Id. SM 1-208-4124741 WW 1-20"12-2965 Sy I E 46&5341 F 3x I 4 X.- Jeff Hackworth of 5 & B Plumbing of Rexburg is allowed -to pull, pay and sign on all permits. If youhave any questions please call me. State of Iftho - [Arvisicaof Building Saftty 1090 E. WaRMowm Slrai6l -Weddian ID 83642 (208) 334.,3950,'. wwWZs1aWjd.vLs1d bs STEVEN -'S-'SPE NGE'., 1swed sgkjeck 16 1higi pr of IdahGC,We Thanks 7 )ave u L rk Kempthorne Wffinistrator Govemor Llexerswo issued res 9773 Ogn6a7r un 1007 a &— . 6 -ClIq 440 dk;4 1p:s COMPANr PROTBUr NOc C -I 7 its WE ARE SEM)M Yo(y. w L c" -M-1; S�IVCL��:2 POR YCKJR USE AS FJKPMTM FOR RMIEW ANDamoom Ji v I W -d ol blk R �)TTOlam[ OPENING 12EINFOIZGEMENT IN 81' GONGRETE 6�RAC�E WALL G- I S STRUGTURAL EN&INEERS TI 600 JOHN AD5 PKNY. %ITE 200 IDAHO FALLS, U. b3401', (20b)525-6ql8 566 TALON DRIVE EXTEND 24" MIN. F�ST OPEN I NC:;7 f FROJEGT No. 5HEET NO. DATE ,,/2 /05 LU T �LUW T- () OPENING 12EINFOIZGEMENT IN 81' GONGRETE 6�RAC�E WALL G- I S STRUGTURAL EN&INEERS TI 600 JOHN AD5 PKNY. %ITE 200 IDAHO FALLS, U. b3401', (20b)525-6ql8 566 TALON DRIVE EXTEND 24" MIN. F�ST OPEN I NC:;7 f FROJEGT No. 5HEET NO. DATE ,,/2 /05