Loading...
HomeMy WebLinkAboutTRUSSES - 05-00041 - 587 Johnson St - New SFR03/25/2005 14:35 425869790� TRUS JOIST PAGE 01/05 r✓ � AWeyerhaeuser Business Northwest Region ♦ 8650 154th Avenue Northeast ♦ Redmond, WA 98052 Phones: 425-869-9700 6 800-648-3936 6 Fax: 425-869-7900 DATE: March 25, 2005 TO: Bob Mortensen BMC West Idaho Falls, ID FAX: 208-522-2106 CC: Lloyd Ayers FROM: Jim Anderson, PE SUBJECT: 587 Johnson Rexburg, ID Trent Harris Construction Number of Pages: 5 This facsimle may contain confidential Information that Is not Intended for distribution to any one other than the Intended recipient listed above. In the event the Intended recipient or an employee responsible for delivering this facsimile to the Intended recipient Is unavailable, please do not disMbute this Iacslmlle, notify us In medlately by telephone, and retum this facsimile by mail. Thank you. COMMENTS: Bob, The (2)11 7/8" TJI®110 joists at 16" on center will be structurally adequate with the notches to the top flange as detailed in the TJ-Beam calculations. The calculations, based on spans and loads you provided, can be identified by the following date and time shown in the upper left hand comer of the calc: 3/25/2005 2:20:10 PM 3/25/2005 2:20:50 PM Please call with any questions. Thank you Si ere] James M.Anerson Trus Joist Engineering 03/25/2005 14:35 42586979R" TRUS JOIST PAGE 03/05 t TJ48eam® 6.16 Serial Number; 7000 008000 beer 4 _q"rm05 2:20'10 PM 11 7/8" TJI@ 110 @ 16" We Pege2 ft1naverstoml.1e5 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED A,R_DITIONAL NOTES: -IMPORTANTI The analysis presented is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with current TJ materials and code accept d design values. TJ Engineering has verified the analysis. The Input loads and dimensions have been provided by others ( 2o1� Vkx--�cni .r� w and must be verified and approved for the specific application by the design professional for the project. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above. Operator Notes: -The 11 7/8" TJI6110 joist at 16" on center will be structurally adequate with the 1/4" notch as detailed. -Any deviation will require further analysis r ,r 2-6 y N oTCH 1 N'N SIDE-, ( 1_0 fu (' 1110 -50).S-F AT- PROJECT INFORMATION: 687 Johnson Street Rexburg, ID copyright CD 2004 by True Joist, a Neyarhaeeser Business TJI6 and TJ-BeasM are registered trademarks of Trus Joist. e-I Joistw,Prol" and TJ-Prow are trademarks of Tres Joist. D:\UserData(Northwest)\Jobs\TJ-Beam12005\S87 Johnson.sms OPERATOR INFORMATION: Jim Anderson Trus Joist 8650 154th Ave. Northeast Redmond, WA 98052-9805 Phone: 888-448-4856 Fax :425-869-7900 AndersJ@trusloist.com 03/25/2005 14:35 42586979P— TRUS JOIST PAGE 02/05 O nw A'ifkyerha¢uur Businm U-Beam06.16 serial Number. 7000000000 11 7/8" Tile 110 @ 16" o/c P ge; �neVention:l s.5 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED yeti D ETAI L N IV �'2 Product Diagram Is Conceptual. LOADS- Analysis. Is for a Joist Member. Primary Load Group - Residential - Living Areas (psf): 40.0 Live at 100 % duration,10.0 Dead SUPPORTS: Input Bearing Vertical Reactions (Ibs) Width' Length Live/Dead/Upllft/Total 1 Plate on masonry wall 5.50" 4.25" 407 / 102 / 0 / 508 2 Plate on masonry wall 5.50" 4.25" 407 1102 / 0 i 508 Detail Other A& Rim Board 1 Ply 1 1/4" x 11 7/8" 1.3E TlmberStrandO LSL A& Rim Board 1 Ply 1 1/4" x 11 7/8" 1.3E TimberStrand® LSL -CAUTION: Required bearing length(s) exceed the minimum shown in the TJ Builder's guide for single family residential applications. Limits: End supports, 31/2" . Intermediate supports, 31/2" with web stiffeners and 51/4" without web stiffeners. -See TJ SPECIFIER'S / BUILDERS GUIDE for detaii(s): A3: Rim Board .00 TION ANALYSI& User Location "X" (Horiz.) Dimension Comment 1 2' 6" 114" into side of top flange DESIGN CONTROLS: Maximum Design Control Control Location Shear (Ibs) 483 478 1560 Passed (31 %) Lt. end Span 1 under Floor loading Vertical Reaction (Ibs) 483 483 1350 Passed (36%) Bearing 1 under Floor loading Moment (Ft-Lbs) 1752 1762 3015 Passed (58%) MID Span 1 under Floor loading Live Load Defl (in) 0.199 0.363 Passed (11873) MID Span 1 under Floor loading Total Load Defl ((n) 0.249 0.725 Passed (L1698) MID Span 1 under Floor loading TJPro 51 Any Passed Span 1 -Deflection Criteria: STANDARD(LL:U480,TL:U240). -Deflection analysis is based on composite action with single layer of 23/32" Structurwood Edge Gold (24" Span Rating) GLUED & NAILED wood decking. -Bracing(Lu): All compression edges (top and bottom) must be braced at T 6" old unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. PROJECT INFORMATION: 587 Johnson Street Rexburg, ID Copyright 0 2004 by Trus Joist, a Weyerhaeuser Business TJ10 and TJ-Beam are registered trademarks of Trus Joist. e-I Joist",Pro" and TJ-Pro" are trademarks of Trus Joist. Ds \UsarData (garthwogt)\Jobs kr s-Room\7nn5\RR 7 .inhnRnn . Rme OPERATOR INFORMATION: Jim Anderson Trus Joist 8650 154th Ave. Northeast Redmond, WA 98052-9805 Phone: 888448-4856 Fax :425-869-7900 AndersJ@trusjoist.com 03/25/2005 14:35 42586979P" TRUS JOIST 7 AAW TJ-BeamG 6.16 Serial Humber.77d 00DOOD `� 91 7/8" TJI®11 O @ 1 S" o/c User: 4 Pagel Engne6VwWcn 10 sg THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED PAGE 04/05 OvemBn mmensim:19' 3" I �� ;® Pit D.iogram is Conceptual. LQ80s: Analysis Is for a Moist Member. Primary Load Group - Residential - Living Areas (psi): 40.0 Live at 100 % duration, 10.0 Dead SUPPORTS: Input Bearing Vertical Reactions Ply Depth Nailing Detail Other Width Length (Ibs) Depth Live/Desd/UpliftlTotal 1 Plate on 5.50" 4.25" 267 / 63 / 0 / 330 N/A NIA N/A A3: Rim Board 1 Ply 1 1/4" x 11 7/8" 1.3E masonry wall TmberStrand® LSL 2 Stud wall 3.50" 3.50" 631 / 158 / 0 / 788 NIA NIA N/A 83 None 3 Mlcrollam LVL 5.50" Hanger 205 / 361-261241 1 11.88" N/A H1: Face Mount None beam Hanger -CAUTION: Required bearing length(s) exceed the minimum shown In the TJ Builder's guide for single family residential applications. Limits: End supports, 31/2" . Intermediate supports, 31/2" with web stiffeners and 51/4" without web stiffeners. -See TJ SPECIFIER'S I BUILDERS GUIDE for detall(s): A3: Rim Board,B3,H1: Face Mount Hanger HANQERS: Simpson Stronn-Tie® Connectors Support Model Slope Skew Reverse Top Flange Top Flange Support Wood Flanges Offset Slope Species 3 Face Mount Hanger IUT11 0/12 0 No N/A NIA NIA -Nailing for Support 3: Face: 10-N10 , Top N/A, Member: 2-N 10 LOCATION ANALYSIS: User Location "X" (Horiz.) Dimension Comment 1 5' 1I2 of the top flange removed, 6" long PROJECT INFORMATION: 587 Johnson Street Rexburg, ID OPERATOR INFORMATION: Jim Anderson Trus Joist 8650154th Ave. Northeast Redmond, WA 98052-9805 Phone: 888-448-4856 Fax :425-869-7900 AndersJ@trusjoist.com Copyright 0 2004 by Trus Joist, a Weyerhaeuser Business TJI6,TJ-Beam and HicrollamS are registered trademarks of Trus Joist. e-I Joist'",Pro" and TJ-Pro" are trademarks of Trus Joist. Simpson Stronq-TieO Connectors is a registered trademark of Simpson Strong -Tie Company, Inc. D:\UaarDate(Northuest)\Jobs\TJ-Beam\2005\Sa7 JohnsonA.sms 03/25/2005 14:35 42586979r'� w■d TRUS JOIST PAGE 05/05 F! rr-eeaunme a.16 serrar Nn 000' 00000oo�"�" User. 4 3125=6 2:20:60 PM 11 7/8" TJ I®110 @ 16" We Paget r gtnevesrcn:l.16.5 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED P_ESIGN CONTROLS: Maximum Design Control Control Location Shear (Ibs) -434 -406 1716 Passed (24%) Rt. end Span 1 under Floor loading Vertical Reaction (Ibs) 788 788 1935 Passed (41%) Bearing 2 under Floor loading Moment (Ft Lbs) -776 -776 3015 Passed (26%) MID Span 1 under Floor loading Live Load Defl (in) 0.048 0.272 Passed (U999+) MID Span 1 under Floor ALTERNATE span loading Total Load Defl (in) 0.056 0.544 Passed (U999+) MID Span 1 under Floor ALTERNATE span loading TJPro 63 Any Passed Span 1 -Deflection Criteria: STANDARD(LUL1480JI-1/240). -Deflection analysis Is based on composite action with single layer of 23/32" Structurwood Edge Gold (24" Span Rating) GLUED & NAILED wood decking. -Brecing(Lu): All compression edges (top and bottom) must be braced at 5' 3" olc unless detailed otherwise. Proper attachment and positioning of lateral bracing Is required to achieve member stability. The load conditions considered in this design analysis include alternate member pattern loading. ADDITIONAL OTE • -IMPORTANTI The analysis presented Is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with current TJ terils n ad code accept design values. TJ Engineering has verified the analysis. The input loads and dimensions have been provided by others oe�. w and must be verified and approved for the specific application by the design professional for the project. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLYI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above. Opgrator Notes: -The 11 71W TJW 110 joist at 16" on center will be structurally adequate with the 1/2 the top flange removed as detailed. Any deviation will require further analysis EROJECT INFORMATION: 587 Johnson Street Rexburg, ID OPERATOR IN -FORMATION: Jim Anderson Trus Joist 8650154th Ave. Northeast Redmond, WA 98052-9805 Phone: 888-448-4856 Fax :425-869-7900 AndersJ@trusjoist.com Copyright 0 2004 by Trus Joist, a Weyerhaeuser Business TJIe9,TJ-8eata* and Microllam* are registered trademarks of Trus Joist. e-I Joist'",Pro- and TJ-Pro" are trademarks of rrus Joist. Simpson Strong -Tie® Connectors is a registered trademark of Simpson Strong -Tie Company, Inc. D:\UserData(Worthwestr\Jobs\TJ-Seam\2005\5e7 JohnsonA.sms I1 , I 3715 Bombardier Ave. YOUR TR US Idaho Falls, ID 83402 Office: (208) 523-6691 EXPERTS Fax: (208) 522£459 pI REXBURG, ID. SPECIAL INSTRUCTIONS: ORDER DATE 10/29/04 Confirmed 10/29/04 Date Roof Trusses FEB DELIVERY LIST TRENT HARRIS.. HENDERSON SPEC 7 0 Date 11/03/04 Page 1 JOB # 10146-04 BID # SALES REP JOHN ROBERTS BY DATE BID JR / / LAYOUT JR 10/29/04 ENG. BY JR 10/29/04 11/09/04 JOBSITE PHONE # PROFILE LABEL QTY TIC PITCH SPAN CANTILEVER OVERHANG BRACING NOTES BIC PITCH TIC LMI BIC LM LEFT RIGHT LEFT I RIGHT # ROWS Al 8 6.0.00 5-08-08 02-00-0 102-00-00 0 3.0.00 A1AS 1 6.0.00 5-08-08 04-00-1 02-00-0 02-00-0 0 AtAV 1 6.0-00 Sx08-08 02-00-0 3 I� 3.0.00 AIBS 1 6.0.00 3.0.00 5-08-08 04-OD-1 02-OD-0 02-00-09 2 2%4 A16V 1 3.0.00 Sx08-08 02-00-0 2 A1C 1 6.0.00 0.0.00 5-08-08 02-00-0 0 2x4 2x4 A1CS 1 6.0.00 3.0.00 5-08-08 zx4 zx4 04-00.1 02-00-0 02-00-0 2 AIDS 1 6.0.00 3.0.00 5-08-08 zx. zx. 02-00-0 102-00-00 0 Al E 2 6.0.00 0.0.00 5-08-08 zx. zx. 02-00-0 02-00-00 0 .� A1F 2-2 6.0.00 0.0.00 5-08-08 zx. zx. 02-OG-0 02-00-00 0 A1V 5 6.0-00 5X4 02-00.0 1 3.0.00 ..4 61 3 6-0-00 7X4 7-08 02-00-0 02-00-00 0 0.0.00 .. BIG 1 6.0.00 7-07-08 02-00-0 02-00-00 1 0.0.00 zx. zx. B1GD 1-2 6.0.00 7-07-08 02-00-0 2 0.0.00 z%. CI 1 60.00 13-04-00 02-00-0 02-00-00 0 0.0.00 2x4 zx. c1G 1 0.0.00 13x04-004 02-00-0 02-00-0 0 ® HF 2 13-20 3 0.0.0019x08-004 A 25 6.0.00 8-00-00 02.00-0 0 0.0.00 z%. z%. J1A 6 6.0.00 5-11-114 02-00-0 0 24 JIB 6 6.0.00 3x11-11 02-00-0 0 0.0.00 ,%. J1c 6 0.0.00 1x11-11 02-00-0 o K1HJ 3 4.2.00 11x03-12. 02-09-1 0 0.0.00 V1 1 6x11-00 0 0.0.00 0.0.00 Items QTY ITEM TYPE DESCRIPTION NOTES Date 11/03/04 Page 2 DELIVERY LIST TRENT HARRIS 0 HENDERSON SPEC 7 iaano Fails, io eaaoi YOUR TRUSS Office: (208)523-6691 EXPERTS Fax: (208) 522-6459 DELIVERY & MISC INFO: r' REXBURG, ID 0 JOB # 10146-04 BID # SALES REP JOHN ROBERTS BY DATE BID JR LAYOUT JR 10/29/04 ENG. BY JR 10/29/04 SPECIAL INSTRUCTIONS: ORDERDATE 10/29/04 Items Confined 10/29/04 equested 11/09/04 JOBSITE PHONE# Date elivery Date CITY ITEM TYPE DESCRIPTION NOTES 3 KANT SAG HJC26 22 KANT SAG JUS24 9 KANT SAG THD26 Trusses can cause property damage or personal injury if improperly installed or braced. Customer's or his agent acceptance hereof shall constitute his affirmative representation that he is fully trained in proper safe methods of truss installation and bracing. Refer to the provided pamphlet entitled " Bracing Wood Trusses: Commentary and Recommendations", published by Truss Plate Institute, Inc. Do not cut, alter, or use damaged trusses without engineering approval. It is the customers responsibility to provide access to the job site. Trusses remain our property until full payment is made. Accepted By: Date: bow �71710 <-Ir .. MiTekl; pc�oM� Re: 10146-04 D EFR 005CITY EXBURG MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 9161676.1900 Fax 9161676-1909 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by BMC West -Idaho Falls, ID. Pages or sheets covered by this seal: R14144424 thru R14144447 My license renewal date for the state of Idaho is January 31, 2005 QQ�FQ &\ST6 C. ANC" November 3,2004 Anderson, Bob The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-2002 Chapter 2. 10146-04 IA1 BMC WEST (IDAHO FALLS), IDAHO SCISSORS 8 I 1 Job Re 6.100sSep 17 a R1414442 nc. Wed Nov 0311:23:52 2004 Panel -2-0-0 , 6-4-10 12-1-7 , 17-10-4 , 23-7-1 29-3-14 35 f3-8 , 37-8-8 2-0-0 6-4-10 5.8.13 5-8.13 5-8.13 5.8-13 6-4-10 2-0-0 Scale = 1:65.9 5x6 M1120 11 E 9.3.1 17-10-4 26-5-7 35-8-8 1 i 9-3.1 8.7-3 8.7-3 9.3-1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 35.0 • Plates Increase 1.15 TC 0.88 Vert(LL) -0.80 K L >527 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 1.00 Vert(TL) -1.16 J-K >365 180 BCLL 0.0 Rep Stress Incr YES WB 0.82 Horz(TL) 0.83 H n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 133lb LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E WEBS 2 X 4 SPF Stud/Std *Except* E-K 2 X 4 SPF 165OF 1.5E WEDGE Left: 2 X 4 SYP No.3, Right: 2 X 4 SYP No.3 REACTIONS (lb/size) B=1920/0-5-8, H=1920/0-5-8 BRACING TOP CHORD Sheathed or 2-1-6 oc pudins. BOT CHORD Rigid ceiling directly applied. Max Horz B=201(load case 5) Max Uplif!B=855(load case 5), H=-855(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/73, B-C=-5730/2372, C-D=-5212/2230, D-E=-3818/1440, E-F=-3818/1463, F-G=5212/2028, G-H=-5730/2177, H-1=0/73 BOT CHORD B-L=-2210/5114, K-L=-1674/4404, J-K=1411/4404, H-J=-1826/5114 WEBS E-K=-1145/2830, C-L=-445/237, D-L=-414/567, D-K=-1040/610, F-K=1040/616, F-J=-423/567, G-J=-445/246 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp Q enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) B, H considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. LOAD CASE(S) Standard ® WARMW - Ver(ry design parameters and READ NOTES ON 7 AND MCWDED EQTEK REFERENCE PAGE AW 7473 BEFORE OS& Design void for use only with Milek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary tracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, derivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. S0OST FR C'�F QQ Q�C F� F9 10243 o � 0 O TF o f T C. ANO November 3,2004 7777 Greenback Lane i..r...m Suite 109 Citrus Heights, CA, 95610 M iTeke 4 Job 10146-04 Truss Al AS Type SPECIAL City 1 Ply 1 qw R1414442 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:23:53 2004 Page 1 -240.0 , 2-0-0 , 4.8.2 11-10.13 , 17-10.4 23.9-11, , 29-9-1 , 35-8-8 2-0-0 2-0.0 245-2 7-4.11 5.11-7 5.11-7 5-11-7 5-11-7 2-0-0 Scale = 1:78.0 5x6 M1120= 6.00 12 F 5x6 M1120G 5x6 M1120,Z E G US M1120 i 1.5x4 M1120 5x8 M1120 H D L C 64 M1120= �? B d M K I IC? A 4x8 M1120� J 3x4 M1120- .7 3.00 12 P O 4x8 MII20� 3x6 M1120= 3x8 M112011 3x4 M1120= 5x*W20 2-0-0 i 440.10 8-11-2 17-10.4 26-9.6 35.8-8 2-0-0 2-0.10 4-5-0 B-11.2 8.11-2 8-11-2 0.5-8 Plate Offsets KY): [C:0-3-0,0-3-01, [E:0-3-0,0-3-01, [G:0-3-0,0-3-01, [I:0-2-4,0-0-131 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.70 Vert(LL) 0.48 K-L >784 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.83 Vert(TL) -0.69 K-L >541 180 BCLL 0.0 Rep Stress Incr YES WB 0.91 Horz(TL) -0.43 O n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 139 lb LUMBER BRACING TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 2-10-6 oc pudins. BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 4-8-13 oc bracing. WEBS 2 X 4 SPF Stud/Std *Except* D-M 2 X 4 SPF 165OF 1.5E, F-L 2 X 4 SPF 1650F 1.5E REACTIONS (lb/size) 0=2179/0-5-8, 1=1664/0-5-8 Max Horzl=225(load case 6) Max UpliftO=-969(load case 5), 1=-776(load case 6) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD A-B=0175, B-C=455/787, C-D=-911/1563, D-E=2086/992, E-F=2743/1158, F-G=-2740/1134, G-H=4205/1943, H-1=4752/2106, I-J=0/73 BOT CHORD B-P=-692/497, O-P=95/63, N-0=-2173/960, D-N=-2103/907, M-N=-1166/862, L-M=-863/2473, K-L=-1456/3482, I-K=-1998/4228 WEBS C-P=207/279, D-M=1130/2829, E-M=-1075/310. E-L=-259/233, F-L=-871/1856, G-L=1094/641, G-K=392/523, H-K=-460/246, N-P=-675/489, C-N=614/407 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) I considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. LOAD CASE(S) Standard WNAL OST FR�o%i��9 10243 -9T PLO O� OF r c- Alp November 3,2004 7777 Greenback Lane ss*® A WARJYDyO - Vero design pararneoers and READ POTEB ONTIDS AND DYCGUDED M17ER REFF.RF,XCE PAGE 3TII 7473 EEFORB USE. Suite 109 Design valid for use only with M iTek connectors. This design is based only upon parameters shown, and is for an individual building component. CMus Heights, CA, 95610 Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibiflity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M i%k` Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison. WI 53719. Job 1A1AV Truss I i�ryp 10146-04 SPECIAL vl� Cq 9, 1 1I Job Reference 6.100 s Sep 17 2004 M A .r R1414442 Nov 0311:23:54 2004 Page 1 -2-0-0 , B-0-0 , 16-0-0 19-8-8, _ 27-8-8 35-8-8 , 2-0-0 8-a0 8-0-0 3.8-8 8-a0 B-0-0 6.00 F12 3.00 f 12 6x8 MI120= 5x8 M1120= D F 4x4 M1120 11 H 4xl6 M1120= , 8.0.0 15.11-8 25-10-0 35-8-8 8.0.0 7-11-8 9-10-8 9-10.8 in= Scale = 1:67.8 a? N 46 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.96 Vert(LL) -0.53 J-K >797 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.97 Vert(TL) -0.78 J-K >544 180 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.47 G n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 153lb LUMBER BRACING TOP CHORD 2 X 4 DF 240OF 2.0E 'Except* TOP CHORD Sheathed. D-E 2 X 4 SPF 165OF 1.5E, E-G 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 4-6-11 oc bracing. BOT CHORD 2 X 4 SPF 1650F 1.5E *Except* WEBS 1 Row at midpt C-J, H-J, E-H B-K 2 X 4 DF 240OF 2.0E WEBS 2 X 4 SPF Stud/Std *Except* H-J 2 X 4 SPF 165OF 1.5E, D-J 2 X 4 SPF 1650F 1.5E REACTIONS (Ib/size) G=1724/Mechanical, B=1929/0-5-8 Max Horz B=379(load case 5) Max UpliftG=-766(load case 6), B=831(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/73, B-C=-5764/2455, C-D=-4322/1724, D-E=3573/1509, E-F=-2933/1396, F-G=3208/1353 BOT CHORD B-K=-2459/5135, J-K=2411/5135, 1-J=fi5/158, D-J=689/1519, H-1=-5/83, G-H=1118/2739 WEBS C-K=-134/282, C-J=-1322/798, H-J=-984/2858, E-J=-587/1244, E-H=390/127, F-H=-617/325 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girders) for truss to truss connections. 6) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. LOAD CASE(S) Standard QQO�P�SNAL �OS 10243 OO Z 9TF O F �4T C AVA November 3,2004 ® WARNWO - Veri;/,4 design parameters and READ NOTES ON THIS AND DVCLUDED 1sQTEB REFERENCE PADS AW 7473 BEFORE USE. 7777 Greenback Lane i ® Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual buildingcomponent. Suite 109 pong shown Citrus Heights, CA, 95610 Applicability of design poramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown � a for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control. storage, delivery, erection and bracing, consult ANSI/rPl1 Quality Criteria, OSB-89 and BCS11 Bu1lding Component M iTekCD Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison. WI 53719. .-S R141 z IJob 10146-04 Al BS I SPECIAL 11 I 1 I Job Reference (optional) ALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:23:55 2004 Page 1 -2-0-0 i 2-31 i 4.6-2 8.0.0 18-0.0 194-8 27-8-8 35-8-8 37-8-8 2-0-0 2-3.1 2-3.1 3-5-14 8-0.0 3.8.8 8-0-0 B-0-0 2-0.0 Scale = 1:80.1 5x8 M1120 = 6x10 M[120H = 6.00 F12 F- G 54 MI12075-' 5x6 M1120� 5x8 M1120 i E H 3x4 1011120 --�- C& D L C 6x8 M1120= ro B d M A It K 1 08 M1120Z� J I.+ 4x12 M1120= 3.00 12 p 0 08 M1120ZL- 3x6 M1120= 3x8 M1120 II 3x4 M1120= 5x1$'W20 : 2-3.1 4-0.10 8-11-2 17-10.4 26-9-6 35-8.8 2-3-1 1-9-9 4.5-0 8.11-2 8-11-2 8.11-2 0-5-8 Plate Offsets (X,Y): [E:0-3-0,0-3-01. [F:0-4-0,0-1-151, [G:0-4-4,0-1-01, [H:0-3-0,0-3-01, [I:0-2-4,0-0-131 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.79 Vert(LL) -0.43 K-L >860 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.16 BC 0.91 Vert(TL) -0.64 K-L >581 180 M1120H 148/108 BCLL 0.0 Rep Stress Incr YES WB 0.87 Horz(TL) 0.38 1 n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 147lb LUMBER BRACING TOP CHORD 2 X 4 DF 240OF 2.0E 'Except* TOP CHORD Sheathed or 3-0-1 oc pudins. F-G 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 2-5-1 oc bracing. BOT CHORD 2 X 4 SPF 165OF 1.5E •Except• WEBS 1 Row at midpt F-M, G-K D-0 2 X 4 SPF Stud/Std WEBS 2 X 4 SPF Stud/Std *Except D-M 2 X 4 SPF 165OF 1.5E REACTIONS (lb/size) 0=2179/0-5-8, 1=1664/0-5-8 Max HorzO=-209(load case 6) Max Uplift0=954(load case 5). 1=-766(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0l75, B-C=451/791, C-D=858/1705, D-E=2296/844, E-F=2189/888, F-G=-2965/1033, G-H=4405/1836, H-1=-4714/1810, I-J=0173 BOT CHORD B-P=-679/491, O-P=-155/212, N-0=-2174/942, D-N=-2055/879, M-N=-1537/768, L-M=-662/2577, K-L=-668/2812, I-K=-1485/4188 WEBS C-P-175/301, N-P=-624/316, C-N=-799/395, D-M=1471/3501, E-M=499/260, F-M=-847/212, F-L=377/1113, G-L-254/648, G-K=-952/1440, H-K-512/283 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL= 4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. ANAL 3) Provide adequate drainage to prevent water ponding. C,S` 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated.5 T�9� 6) Bearing at joints) I considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of Q �• Q 9 bearing surface. LOAD CASE(S) Standard 1 1 10243 o o f �T C ANQ� November 3,2004 A WARNDVO - Verft design parometera and READ NOTES ON TffiS AND DWJ=ED AffrEK MWERENCE PADS JIW 7473 BM70RE QSE. 7777 Greenback Lane �ws� n valid for use on with MTek connectors. This n is based on upon parameters shown, and is for an individual building component. Sure 108 Design only design b po pa 9 poneni. citrus Heights, CA, 95610 Applicability of design poramenters and proper incorporation of component a responsibility of building designer - not tens designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Critedo, DSB-89 and BCSI1 Building Component M'Tek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madhon, wl 53719. Ply R14 110146-04 I Al BV I SPECIAL 11 1 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:23:57 2004 Page 1 -2-0.0 7-0-0 , 1440.0 15.11-8 , 21-8-8 28.8-8 35.8-8 , 2-0-0 7-0.0 7-0.0 1-11-8 5.9-0 7-0-0 7-0-0 Scale = 1:67.8 3.00 12 7x8 M1120= 6.00 12 3x4 MII20 It US MI120= D -- E F J 4x4 M1120 11 I 4x16 M1120= N r: 7-11-12 , 15-11-8 25-10-0 , 35-8-8 , r r r i 7-11-12 7-11-12 9-10-8 9.10-8 LOADING (psf) SPACING 2-0-0 CSI TCLL 35.0 Plates Increase 1.15 TC 0.76 TCDL 7.0 Lumber Increase 1.15 BC 0.97 BCLL 0.0 Rep Stress Incr YES WB 0.97 BCDL 7.0 Code IRC2000/ANSI95 (Matrix) LUMBER TOP CHORD 2 X 4 DF 240OF 2.0E *Except* D-F 2 X 4 SPF 1650F 1.5E, F-H 2 X 4 SPF 1650F 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E "Except* B-L 2 X 4 DF 240OF 2.OE, E-J 2 X 4 SPF Stud/Std WEBS 2 X 4 SPF Stud/Std 'Except* I-K 2 X 4 SPF 1650F 1.5E, F-K 2 X 4 SPF 1650F 1.5E REACTIONS (lb/size) H=1725/Mechanical, B=193010-5-8 20 = DEFL in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.62 K L >686 240 M1120 197/144 Vert(TL) -0.91 K L >465 180 Horz(TL) 0.52 H n/a n/a Weight 149 lb BRACING TOP CHORD Sheathed or 2-6-3 oc pudins. BOT CHORD Rigid ceiling directly applied or 5-3-7 oc bracing. WEBS 1 Row at midpt I-K, F-1 Max HorzB=360(load case 5) Max UpliftH=-718(load case 6), B=-817(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/73, B-C=-5816/2411, C-D=5512/2414, D-E=-4948/1967, E-F=4938/1936, F-G=2875/1234, G-H=-3250/1272 BOT CHORD B-L=2409/5191, K-L=1676/4184, J-K=63/152, E-K=-434/191, 1-J=0/55, H-1=-1057/2790 WEBS C-L=-373/198, D-L=-725/1083, D-K=-698/1603, I-K=983/2933, F-K=1034/2479, F-1=674/207, G-1=531/291 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. ANAL 6) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of Srj,\ bearing surface. � �0��(,` S T89� /2�� LOAD CASE(S) Standard 10243 qT Alp o� OF rc-M4 November 3,2004 ® WARMM - verify design parametms and READ NOTES ON Tius AND iNcumaD xr=REFERENCE PAGE MU 7473 BEFORE USE. 7777 Greenback Lane r+s!a Design valid for use only with MTek connectors. This design is based only upon parameters shown, and 6 for an individual budding component. Suite 109 Applicability of design poramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsrbillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criferla, DSB-89 and BCSII Bullding Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. ' e Job Truss VVit Type Qty Ply VW R1414442 10146-04 Al C HIP 1 1 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:23:58 2004 Page 1 1-2-" 6.0-0 , 12-0-0 17-10 4 23.8.8 29-8-8 3541-8 , 2-0-0 6-0-0 6.0-0 5-10.4 5-10-4 6.0.0 6.0.0 Scale = 1:66.6 54 M1120= 1.5x4 M1I20 II 5xS M1120= D E F ?n= K J 3x4 M1120= 5x8 M1120= I 3x4 M1120= , 10-0-0 17-10-4 25.8-8 , 35.8.8 , 10-0-0 7-10-4 7-10-4 10-0-0 W N Cb I� Plate Offsets (X,Y): wo-1-10,Edge1, [Lu-4-0,0-1-151, [F:0-4-0,0-1-151, 111:0-1-10,Edge], [J:0-4-0,0-3-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.80 Vert(LL) -0.25 H-1 >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.73 Vert(TL) -0.45 H-1 >940 180 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(TL) 0.14 H n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Simplified) Weight 137lb LUMBER BRACING TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 3-2-2 oc pudins. BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 6-6-1 oc bracing. WEBS 2 X 4 SPF Stud/Std REACTIONS (lb/size) H =1 731 /Mechanical, B=1924/0-5-8 Max HorzB=165(load case 5) Max UpliftH=-690(load case 6), B=803(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/38, B-C=-3057/1127, C-D=-2649/1046, D-E=-2585/1041, E-F=-2585/1041, F-G=2663/1052, G-H=-3084/1137 SOT CHORD B-K=-1042/2704, J-K=838/2259, I-J=-777/2267, H-1=-947/2736 WEBS C-K=-411/224, D-K=270/383, D-J=-277/651, E-J=-546/217, F-J=-274/642, F-1=276/397, G-1=-432/232 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girders) for truss to truss connections. LOAD CASE(S) Standard cxONAL CQO�Q�G S T�e , 10243 O � .� 0 OF�o��� T C. ANO November 3,2004 WARNING - Verb design parameters and READ NOTES ON TBIS AND INCLUDED WTES REFERENCE PAGE MB-7473 BEFORE USE. 7777 Greenback Lane Design void for use only with M*Iek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite 109 CiWs Heights. CA 95610 App5cabilrty of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsbil5ty of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Qualify Criteria, DSB-89 and SCSI1 Building Component iTek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive. Madison. WI 53719. .It R14 10146-04 I Al CS I SPECIAL I 1 I ' ,lob Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:23:59 2004 Page 1 -2.0.0 , 2-3-1 , 4-6-2 _, 7-0-0 — , 14-0-0 21-8-8 28-8-8 35.8-8 , 3748-8_, 2-0-0 2-3.1 2.3.1 2-5-14 7-0.0 7-8-8 7-0.0 7-0.0 2-0-0 Scale = 1:70.9 US M1120= 5x8 M1120= F G 6.00 12 3x8 MI120-:r- 1.5x4 M1120 i cc 3x4 M112011 E H 9 3x4 M1120G L ti D C 6x8 M1120= B M K o A '9X12 M1120r 3x4 M1120� 3.OD 12 3x4 M1120� jq 3x6 M1120= ci • P O 4x8 MII20= 3x8 M112011 3x4 M1120= 4-6.2 2-3-1 4-0-10 B-11.2 17-10.4 26-9-6 35-8-8 2-3-1 1-9.9 4-5-0 8-11-2 8-11-2 8.11-2 0-5-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defi Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.83 Vert(LL) -0.51 K-L >728 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.85 Vert(TL) -0.77 K-L >487 180 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(TL) 0.50 1 nla n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 134 lb LUMBER BRACING TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 2-6-0 oc purtins. BOT CHORD 2 X 4 SPF 1650F 1.5E *Except' BOT CHORD Rigid ceiling directly applied or 2-8-6 oc bracing. D-0 2 X 4 SPF Stud/Std WEBS 1 Row at midpt E-N, F-M WEBS 2 X 4 SPF Stud/Std `Except F-L 2 X 4 SPF 165OF 1.5E, G-L 2 X 4 SPF 165OF 1.5E REACTIONS (lb/size) 0=2179/0-5-8, 1=1664/0-5-8 Max Horz0=189(load case 6) Max UpliftO=-935(toad case 5), 1=-752(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0l75, B-C=-4531796, C-D=826/1612, D-E=-798/1621, E-F=2089/924, F-G=-3945/1376, G-H=-4265/1677, H-1=4739/1784, I-J=0/73 BOT CHORD B-P=-684/493, O-P=-139/197, N-0=-2174/923, D-N=-190/67, M-N=-545/1115, L-M=807/2636, K L=-856/3198, I-K=-1468/4214 WEBS C-P=-158/282, N-P=627/328, C-N=-711/367, E-N=3452/1447, E-M=-338/819, F-M=-1072/282, F-L=-564/1699, G-L=-444/1039, G-K=665/872, H-K=-425/266 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) I considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. LOAD CASE(S) Standard I Vo QQO�P�G S T� FO/2FF9 10243 9T 00 OF T C. AND November 3,2004 - 7777 Greenback Lane ...n..,� WAR1ND11Q t7er�{Jj{ desrlQrt paranuters and READ !VOTES ON TS1S AND INCr.UDED 4!lTES REFERENCE PAGE Zip 7473 BEFORE I7SE. Suite 109 Design valid for use only with Welt connectors. This design a based only upon parameters shown, and is for an individual building component. Citrus Heights, CA, 95610 ApplicabiGly of design poramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibilydy of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTek� Safety Information available from Truss Plate Institute. 583 D'Onofrio Drive. Madison, wl 53719. 10146-04 I Al DS I SPECIAL R1414443 WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:00 2004 Page 1 -24)-0 6-0-0 12-0.0 17-10-4 23-8-8 29.8-8 35r8-8 37-8-8 2-0.0 6-0.0 6-0-0 5-10-4 5-10-4 6-0.0 6-0.0 2-0-0 Scale = 1:67.0 12x12 M1120 = 12x12 M1120= 3x4 M112011 D F F 8-11-2 , 17-10.4 26-9-6 35-8-8 , 8.11-2 B-11-2 8-11-2 8-11-2 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.85 Vert(LL) -1.33 K >318 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.55 Vert(TL) -1.87 K >226 180 M1120H 148/108 BCLL 0.0 Rep Stress Incr YES WB 0.96 Horz(TL) 1.14 H n/a n/a BCDL 7.0 Code IRC2000/ANS195 (Matrix) Weight 143lb LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E "Except" D-F 2 X 6 DF 1800F 1.6E BOT CHORD 2 X 4 DF 240OF 2.0E WEBS 2 X 4 SPF Stud/Std *Except* D-K 2 X 4 SPF 1650F 1.5E, F-K 2 X 4 SPF 165OF 1.5E REACTIONS (lb/size) B=1920/0-5-8, H=1920/0-5-8 Max HorzB=147(load case 6) Max UpliftB=-805(load case 5), H=805(load case 6) BRACING TOP CHORD Sheathed or 2-1-2 cc pudins. BOT CHORD Rigid ceiling directly applied or 5-10-7 oc bracing. (1) TOTAL VERTICAL DEFL. OF 1.87 IN. EXPECTED @ JT.K AND HORIZONTAL DEFL. OF 1.14 IN. EXPECTED r@ JT.H (2) PROJECT ENGR. TO VERIFY BOTH DEFLECTIONS AS THEY ARE ADEQUATE TO THE STRUCTURAL SYSTEM. (3) TEMP. SHORING AND CAMBER SUGGESTED (BY OTHERS) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0l73, B-C=-5743/2143, C-D=-5266/2006, D-E=-9749/3596, E-F=-9749/3596, F-G=5266/1934, G-H=-5743/2001, H-I=0/73 BOT CHORD B-L=-1951/5123, K-L=1517/4472, J-K=1376/4472, H-J=-1717/5123 WEBS C-L=-377/240, D-L=-409/505, D-K=-2042/5623, E-K=781/327, F-K=-2177/5623, F-J=-415/505, G-J=377/250 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Special provisions shall be made by the building designer to allow for 0.81 in of horizontal movement due to live load and 1.14in due to total load. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) Bearing at joint(s) B, H considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity, of bearing surface. LOAD CASE(S) Standard F�SSC.>STfq G��y 10243 �o 02 B\ Co AN��P� November 3,2004 7777 Greenback Lane s!® ® t9ARlVDVO • Ver(jtj design par amers cLand RSAD ROTES ON TSIS AND INCLUDED tiQZEB REFERENCE PAGE !� 7473 BEFORE r7S13. Suite 109 Design void for use only with MTek connectors. This design is based any upon parameters shown, and is for an individual building component. Citrus Heights, CA, 95610 Applicability of design poramenters and proper incorporation of component is responsibility of building designer- not tens designer. Bracing shown is for lateral support of individual web members only. Additional temporary, bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 10146-04 AIE HIP 2 1 R1414443 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:01 2004 Page 1 -2-0-0 5-6-7 10-0-0 17-10-4 25-8-8 30-2-1 , 35-8-8 37-8-8 , 2-0.0 5.6.7 4-5.10 7-10.4 7-10.4 4-5-10 5.6-7 2-0.0 Scale = 1:67.0 6.00 F12 1.5x4 M1120,Z�- C r, B �A 5x6 MII20= 6x12 M1120= 6x12 M1120= 3x4 M112011 D E F L K 3x4 M1120= 5x8 M1120= J 3x4 M1120= 10-0-0 17-10.4 25-8-8 35.8.8 , 10-0-0 7-104 7-113-4 10-0-0 Plate Offsets (X,Y): [13:0-1-10,Edge), [D:0-6-0,0-0-151, [F:0-6-0,0-0-151, [H:0-1-10,Edge1, [K:0-4-0,0-3-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lac) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.16 TC 0.46 Vert(LL) -0.26 K >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.73 Vert(TL) -0.43 H-J >990 180 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.14 H n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Simplified) Weight: 153lb LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E -Except' TOP CHORD Sheathed or 3-8-4 oc puffins. D-F 2 X 6 DF 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 6-6-8 oc bracing. BOT CHORD 2 X 4 SPF 165OF 1.5E WEBS 2 X 4 SPF Stud/Std REACTIONS (lb/size) B=1924/0-5-8, H=1917/Mechanical Max HorzB=129(load case 6) Max Uptfftf3=-781(load case 5), H=778(foad case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-13=0/38, B-C=-3091/1166, C-D=-2754/1150, D-E=-3164/1354, E-F=3164/1354, F-G=2769/1156, G-H=-3121/1177, H-1=0/38 BOT CHORD B-L=-1031/2731, K-L=-972/2477, J-K=922/2490, H-J=989/2767 WEBS C-L=298/173, D-L=-216/302, D-K=-431/980, E-K=743/297, F-K=-425/968, F-J=-222/309, G-J=-323/183 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord five load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. LOAD CASE(S) Standard EN�� �C.`'SMAL TEAS �t�cr` 10243 O t�cC` 9rF OF tOP O �4T C. November 3,2004 ® WARMG . 7cr ft dcdgn paramctcrs and REM NOTES ON TMS AND nWCWDED MTZK REFERENCE PRO& AW 7473 BEFORE OSE. 7777 Greenback Lane 09 Design void for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suitt He Applicobiity of design poromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Citrus Fleights, CA 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSIITP11 Quality Criteria, DSB-89 and BCSII Buflding Component M iTek` Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Nlod'aon, WI 53719. R1 10146-04 A1F FALLS), IDAHO FALLS, ID 83402 HIP 2 21 Job Reference 6.100 s Sep 17 2004 M Inc. Wed Nov 0311:24:03 2004 Page 1 -240.0 B-0-0 , 14$13 _ ,_ 21-1-11 _,_ _ _ 27-8-8 ,35$8 37-8 8 2-0-0 B-0-0 6.6-13 6-8-13 6-6-13 8-0.0 2-0.0 Scale = 1:67.0 5x8 M1120= 1.5x4 M1120 11 3x4 M1120= 5x8 M1120= - - M N U V L U K K J S t u 1 V W A 3x4 M1120 11 JUS24 5x8 Ml120= 7x8 MI120 WB= 5x6 Mll20= JUS24 JUS24 3x4 MI12011 JUS24 4x12 M1120-Z�' HJC26 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 JUS24 8-0.0 14-6-13 , 21-1-11 27-8-8 35-8-8 8-0.0 6-6-13 6-6-13 6-6-13 8-0.0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.85 Vert(LL) -0.53 J-L >807 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.77 Vert(TL) -0.72 J-L >587 180 BCLL 0.0 Rep Stress Incr NO WB 0.48 Horz(TL) 0.14 G n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 331 Ib LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 3-9-1 oc pudins. BOT CHORD 2 X 6 DF 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 8-1-5 oc bracing. WEBS 2 X 4 SPF Stud/Std *Except* C-L 2 X 4 SPF 1650F 1.5E, F-J 2 X 4 SPF 1650F 1.5E REACTIONS (lb/size) B=4605/0-5-8, G=5040/Mechanical Max Horz B=114(load case 6) Max UplifS=-2300(load case 5), G=-2567(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/82, B-C=-9225/4791, C-D=11354/6085, D-E=-11351/6084, E-F=-11271/6044, F-G=-9242/4826, G-H=0/81 BOT CHORD B-M=-4238/8107, M-N=4203/8048, N-0=-4203/8048, O-P=-4203/8048, L-P=-4203/8048, L-Q=-5946/11269, K Q=5946/11269, K-R=-5946/11269, J-R=-5946/19269, J-S=-4208/8092, S-T=-4208/8092, T-U=-4208/8092, 1-U=-4208/8092, I-V=-4244/8152, V-W--4244/8152, W-X=-4244/8152, G-X=-4244/8152 WEBS C-M=936/1579, C-L=-2187/4039, D-L=-659/269, E-L=-75/181, E-J=7431300, F-J=2087/3898, F-1=-968/1589 NOTES 1) 2-ply truss to be connected together with 0.131 "x3" Nails as follows: Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and SS�ONAC MCA, 'v ��C. TF left Lumber DOL=1.33 DOL=1.33. k S G right exposed; porch and right exposed; plate grip 5) Provide adequate drainage to prevent water ponding. Q�� Q 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Refer to girder(s) for truss to truss connections. 8) Use USP HJC26 (With 16d nails into Girder & 10d nails into Truss) or equivalent at 8-0-6 from the left end to connect truss(es) J1 (1 pi 2 10 243 X 4 SPF), K1 HJ (1 ply 2 X 6 DF) to front face of bottom chord. 9) Use USP JUS24 nth 10d nails into Girder & 10d nails into Truss) or equivalent spaced at 2-1-8 oc max. starting at 10-0-12 from the le end to 33-9-4 to connect truss(es) J1 (1 ply 2 X 4 SPF) to front face of bottom chord. 10) Fill all nail holes where hanger is in contact with lumber. '9 �.� 0 T P CO o F F� F � �►� cSt�ndard �� %� C, MA November 3,2004 WARNIIVG - Yerj/ij design parameLera and READ ROTES OP THIS AND IIVCLUDED 11IITEB REFERfi1VCE PAGE DQI7493 BEFORE USE 7777 Greenback Lane suite 109 Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual budding component. Applicability of design poromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTek` Safety Information available from Truss Plate Institute. 583 D'Onofrio Drive, Madison, WI 53719. R14 Job Truss 10146-04 IAIF HIP 21 Job 6.100 s Sep Inc. Wed Nov 03 11:24:03 2004 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (pIQ Vert A-C=84, C-F=84, F-H=84, B-G=-14 Concentrated Loads (Ib) Vert K=-364(F) M=-1076(F)1=-364(F) N=-364(F) O=-364(F) P=364(F) Q=-364(F) R=-364(F) S=364(F) T=-364(F) U=-364(F) V=364(F) W=364(F) X=-364(F) ® WARAWG - Verft design pammeters and READ NOTES ON THIS AND INCLUDED MTEK REFERENCE PAGE MU 7473 BEFORE USE. 7777 Greenback Lane Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual buildingcomponent. Suite 109 pong s Citrus Heights. 95610 Applicability of design paramenlers and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown 9 �' is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quailty Criteria, DSB-89 and BCSI1 Bullding Component M ii��K® Salety Information ovoilable from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. i Truss R141 10146-04 IA1F-A IHIP I1000 21 Job Reference (optional) BIVIC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 Mi rek Industries, Inc. Wed Nov 0311:24:04 2004 Page 1 -2-0-0 6.0-0 14-6-13 21.1-11 27-8-8 35-8-8 37-8-8 2-0-0 8-0-0 6-6-13 6-6-13 6-6-13 8-0-0 2.0.0 Scale = 1:67.0 5x8 M1120= 1.5x4 M112011 3x4 M1120= 5x8 M1120= r_ ., I M L K J 3x4 M1120 II 5x8 MII20= U8 M1120 W13= 5x6 MII20= 1 3x4 M112011 8-0.0 14-6-13 21-1-11 27-8-8 35-8.8 8-0.0 6-&13 6.6.13 6.6-13 8-0-0 Plate Offsets (X,Y): [B:0-3-9,0-2-01, [C:0-4-0,0-1-151, [F:0-4-0,0-1-151, [G:0-3-9,0-2-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.67 Vert(LL) -0.44 J-L >960 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.65 Vert(TL) -0.62 J-L >684 180 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(TL) 0.12 G n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight: 331lb LUMBER TOP CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD 2 X 6 DF 180OF 1.6E WEBS 2 X 4 SPF Stud/Std *Except* C-L 2 X 4 SPF 1650F 1.5E, F-J 2 X 4 SPF 1650F 1.5E REACTIONS (lb/size) B=4143/0-5-8, G=4125/Mechanical Max Horz B=-114(load case 6) Max UpliftB=-1560(load case 5), G=1552(load case 6) BRACING TOP CHORD Sheathed or 4-3-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/82, B-C=-8204/3140, C-D=-9879/3918, D-E=-9878/3917, E-F=-9916/3933, F-G=-8240/3153, G-H=0/81 BOT CHORD B-M=2760f7l89, L-M=-2736f7l3O, K-L=-3834/9915, J-K=-3834/9915. l-J=2712f7l78, G-1=-2736f7236 WEBS C-M=665/1576, C-L=-1373/3392, D-L=357/103, E-L=125/43, E-J=386/109, F-J=1371/3386, F-1=-664/1566 NOTES 1) 2-ply truss to be connected together with 0.131"x3" Nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II: Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Refer to girder(s) for truss to truss connections. 8) Girder carries hip end with 8-0-0 end setback. 9) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 8491b down and 306Ib up at 27-8-8, and 8491b down and 3061b up at 8-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 SNAL GOSTER O/yF�9 10243 O � OF �4T C. AX4 November 3,2004 A WAMMM - Verft design pammeters and READ NOTES ON THIS AND MCUMED AITIZE REFERENCE PAGE MU 7473 BEFORE t7SE. 7777 Greenback Lane r..n..r� Design void for use only with M7ek connectors. This design is based only upon parameters shown, and is for on individual building component. Suite 109 Citru Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Heights, CA 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Crilerla, DSB-89 and BCSII Building Component M iTek® Safety Information available from Truss Piste Institute, 583 D'Onofrio Drive. Madison, WI 53719. Job Truss TwapoType ally Ply `111111111111K 10146-04 A1F-A HIP 1000 2 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:04 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert A-C=-84, C-F=-42(F=42), F-H=-84, B-M=-14, I-M=192(F=-178), GI=14 Concentrated Loads (Ib) Vert M=849(F) 1=-849(F) R14 ® WARNING - 9er(jy design parameters and READ NOTES ON THM AND INCLUDED MITER REFERENCE PAGE EW 7473 BEFORE USE. 7777 Greenback Lane Design valid for use only with MTek connectors. This design is based any upon parameters shown, and is for an individual building component. Suite 109 Applicability of design paromenters and proper incorporation'of component is responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Cdlerla, DSB-89 and BCSII Building Component MiTek® Safety information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 10146-04 I A1V I SPECIAL 5 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:05 2004 Page 1 -2-0-0 7-11-12 17-10.4 23.9-11 29-9.1 35.8.8 2-0.0 7-11-12 9.10-8 5-11-7 5-11-7 5-11-7 Scale = 1:67.5 US MI120= 3x4 M112011 F 20= 1( J 4x4 M1120 II 4x12 M1120= 7-11-12 15-11-8 25-10-0 35-8-8 7-11-12 7-11-12 9.10-8 9-10-8 Plate Offsets (X,Y): [B:0-3-6,0-2-0], [C:0-3-0,0-3-0], [H:0-3-0,0-3-0], [I:0-1-10,Edge], [L:0-M,0-5-8], [M:0-4-0,Edge] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.70 Vert(LL) 0.64 L-M >667 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.99 Vert(TL) -0.92 L-M >463 180 BCLL 0.0 Rep Stress Incr YES WB 0.66 Horz(TL) 0.53 1 n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 153lb LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 4 SPF 1650F 1.5E 'Except' E-K 2 X 4 SPF Stud/Std WEBS 2 X 4 SPF Stud/Std 'Except- J-L 2 X 4 SPF 165OF 1.5E, F-L 2 X 4 SPF 1650F 1.5E WEDGE Left: 2 X 4 SYP No.3 REACTIONS (lb/size) 1=1725/Mechanical, 8=1930/0-5-8 Max Horz B=395(load case 5) Max UplifEl=-749(load case 6), B=-848(load case 5) BRACING TOP CHORD Sheathed or 2-6-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 4-4-11 oc bracing. WEBS 1 Row at midpt J-L FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A B=0l73, B-C=-5754/2547, C-D=-5376/2457, D-E=-4140/1764, E-F=-3926/1770, F-G=-3063/1295, G-H=-2856/1261, H-1=3266/1355 BOT CHORD B-M=2573/5125, L-M=2168/4644, K L=63/152, E-L=252/152, J-K=0151, I-J=-1141/2836 WEBS 1­14=494/266, G-J=-622/163, J-L=1051/2811. F-L=-1324/2773, G-L=328/302, C-M=-315/152, D-M=330/440, D-L=-945/560 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed: MWFRS gable end zone; cantilever left -and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. CJ CjTONAL F 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girders) for truss to truss connections. �C. / 5) Bearing at joint(s) B considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of�t� j s bearing surface. LOAD CASE(S) Standard 10243 O � O O T C. qN0 November 3,2004 ® WARNIlirG - DerW design parameters and READ NOTES ON 7 AND n=MZD X17EIT REFERENCE PAGE AW- 7473 BEFORE USE. 7777 Greenback Lane 11111or�40 Design void for use only with MTek connectors. This design is based only upon parameters shown, and a for an individual building component. Sufte 109 Applicability of design rarnenters and proper incorporation of component is responsibility of building designer - not hiss d Citrus Heights, CA 95610 iypa orpora po po 1y ng g designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSIAPI1 Qualify Criteria, DSB-89 and BCSIt Building Component MiTek® Safety Information available from Truss Plate Institute. 583 D'Onofrio Drive. Madison. WI 53719. 10146-04 181 I COMMON BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 3 1 1 s R1414443 2004 Paae 1 r -2.0.0 6.10-14 13-9-12 , 20.8-10 , 27-7-8 29-7-8 2-0-0 6-10-14 6.10-14 6.10-14 6.10-14 2-0.0 Scale = 1:53.8 4x4 M1120= D 3x4 M1120= 5x8 M1120= 9.7-8 18-0-0_ 27-7-8 9-7-8 8-4-8 9-7-8 Plate Offsets MY): [B:0-4-12,0-1-81, [F:0-4-12,0-1-81, [H:0-3-0,0-3-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.72 Vert(LL) -0.21 B-1 >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.68 Vert(TL) -0.37 B-1 >894 180 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.07 F n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Simplified) Weight 100Ib LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 3-9-5 oc puffins. BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 7-5-6 oc bracing. WEBS 2 X 4 SPF Stud/Std REACTIONS (lb/size) B=1525/0-3-8, F=1525/0-3-8 Max Horz B=-165(load case 6) Max UpliftB=-682(load case 5), F=682(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/38, B-C=-2163/857, C-D=-1797/827, D-E=-1797/827, E-F=2163/857, F-G=0/38 BOT CHORD B-1=-797/1921, H-1=-431/1300, F-H=-643/1921 WEBS C-1=-504/263, D-1=386/601, D-H=-386/601, E-H=-504/263 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL= 4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard QQ,KQ�G STE 10243 o � .� o F,4 TF OF 1� �Q O T C. A�yO November 3,2004 ® WARMNG - Ver(& design parameters and READ No7ES oN 77us AND mcumpai mrrzK REFERENCE PAGE MU 7473 BEMRE USE. 7777 Greenback Lane r_r_® Design void for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown suite 109 Citrus Heights, CA 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI1711 Quality Criteria, DSB-89 and BCSII Building Component M iTek� Safety information available from Truss Plate Institute. 583 D'Onofrio Drive, Madison, WI 53719. R14 10146-04 1 BIG I COMMON BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MTek Industries. Inc. Wed Nov 0311:24:07 2004 Page 1 -2-0-0 6-1D-14 13-9-12 20-8-10 27-7.8 29-7-8 , 2-0.0 6.10-14 6-10.14 6.10-14 6-10.14 2-0-0 Scale = 1:53.8 5x6 M1120= 3x6 M1120-::-' 3x4 M1120=- D 5x6 M1120= , 9.7-8 is-" 27-7-8 9-7-8 B-4-8 9.7-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.60 Vert(LL) 0.27 F-H >607 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.92 Vert(TL) -0.34 F-H >477 180 BCLL 0.0 Rep Stress Incr YES WB 0.55 Horz(TL) 0.04 F n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 141 lb LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 4-11-2 oc pudins. BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SPF Stud/5td WEBS 1 Row at midpt D-K OTHERS 2 X 4 SPF Stud/Std REACTIONS ((b/size) B=847/14-7-0, F=1230/0-3-8,1=78/14-7-0, J=448/14-7-0, L=615/14-7-0, M=202/14-7-0, N=64/14-7-0, 0=128/14-7-0 Max Horz B=-1 65(load case 6) Max UpliftB=335(load case 5), F=-558(load case 6), 1=78(load case 1), J=-134(load case 5), L=191(load case 5), M=202(load case 1), 0=23(load case 6) Max GravB=847(load case 1), F=1230(load case 1), 1=44(load case 5), J=448(load case 1), L=615(load case 1), M=99(load case 5), N=84(load case 2), 0=128(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/75, B-C=-1169/336, C-D=-797/313, D-E=1331/595, E-F=1701/631, F-G=0/76 BOT CHORD B-0=-325/929, N-0=-325/929, M-N=-325/929, L-M=-325/929, K-L=-325/929, J-K=172/761, I-J=-172/761, H-1=-172/761, F-H=-426/1407 WEBS C-K=-561/285, D-K=378/137, D-H=-400/638, E-H=561/290 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable ONAL End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �C. / 5) AEI plates are 1.5x4 M1120 unless otherwise indicated. 1 S TFq� 6) Gable studs spaced at 2-0-0 oc. Q Q+ Q LOAD CASE(S) Standard I� 10243 �p �2 BBC 9rFOF SOP Q0 9T C. qN�� November 3,2004 ® WARLNG - Verify design parameters and READ NrOTES ON I AND DVCLrlDED hR7'ER REFERENCE PAGE AW 7473 BEFORE OSE. Suite 09 Greenback Lane N Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual budding component. Citrus Heights, CA, 95610 Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality controL storage, delivery, erection and bracing. consulf ANSIAP11 Quality Crllerla. DSB-89 and BCS11 Building Component M 7ek® Safety Information available from Truss Plate institute. 583 D'Onofrio Drive, Ivtodison, WI 53719. Job russ s ype ty y R14144438 10146.04 B1GD DBL. HOWE 1 2 Job Reference (optional) DM%r vvroo tlUMnu rru.wl, nimnu rhLLrl, Iu 0a9Yc 0. luu s aaP I r cuuq Mi I elc mausmes, Inc. vvev Ivav w I.i:ao:au cuv% raga I -2-0-0 , 8-1-8 — , 13-9-12 , 19-6-0 ,27-7-8 , 2-0-0 8-1-8 6-8-4 5-8-4 8-1-8 Scale • 1:45.1 ex12 M1120 11 13 c 5 W8 M1120 i I n n u L r r ry V r 3x12 M1120 11 Special special 12x12 M112D = 1202 M1120 = Special 3d2 Mt120 11 Special 10x16 M112DH Special Special Special Special Special 608 M112D Special 8-1-8 , 13-9-12 , 19-6-0 , 27-7-8 8-1-8 5-8-4 5-84 8-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.60 Vert(LL) -0.30 H-1 >999 240 M1120 187/144 TCDL 7.0 Lumber Increase 1.15 BC 0.63 Vert(TL) -0.41 H-1 >790 180 M1120H 160/128 BCLL 0.0 Rep Stress Incr NO WB 0.91 Horz(TL) 0.11 E n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matra) Weight 528lb LUMBER TOP CHORD 2 X 8 DF SS BOT CHORD 1.5 X 11.88 LSL Truss Grade WEBS 2 X 4 SPF 165OF 1.5E -Except- B-H 2 X 4 SPF Stud/Std, C-H 2 X 4 DF 240OF 2.0E D-H 2 X 4 SPF Stud/Std WEDGE Left: 2 X 6 DF 180OF 1.6E, Right: 2 X 6 DF 180OF 1.6E REACTIONS (lb/size) A=10099/0-5-8, E=12859/0-5-8 Max Horz A=-116(load case 6) Max Uplift A=-4518(load case 5), E=5550(load case 6) BRACING TOP CHORD Sheathed or 3-9-1 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt B-H, D-H FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=-22276/9854, B-C=-16756/7273, C-D=-1677817285, D-E=-22524/9674 BOT CHORD A-I=-8978/20099, I-J=8978/20099, J-K=8978/20099, H-K=-8978/20099, G-H=8726/20414, G-L=-8726/20414, F-L=-8726/20414, F-M=-8726/20414, M-N=-8726/20414, N-0=8726/20414, O-P=-8726/20414, E-P=-8726/20414 WEBS B-1=2393/4787, B-H=-6014/2985, C-H=-6094/13849, D-H=-6386/2825, D-F=-2146/4908 NOTES 1) 2-ply truss to be connected together with 0.1 31"x3" Nails as follows: Top chords connected as follows: 2 X 8 - 2 rows at 0-9-0 oc. Bottom chords connected as follows: 1.5 X 11.88 - 4 rows at 0-4-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=:4.2psf; BCDL=4.2psf, Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4518 lb uplift at joint A and 5550 lb uplift at joint E. 8) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 48401b down and 24951b up at 8-1-8, 17171b down and 6531b up at 10-0-12, 17171b down and 6751b up at 12-0-12, 17171b down and 7051b up at ___ 14-0-12, 17171b down and 722ib up at 16-0-12, 17171b down and 7351b up at 18-0-12. 1717Ib down and 735Ib uo at 20-0-12. ihi'tFiiidf'gfr��'BiTt4)i�fit98i�Fi�° t �'i �f 7473 EEFOhE USE. Design valid for use only wit ANTek connectors. This design is based only upon pnr ters shown, and is for on individual building component. Ap licability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown LOA4G4W4Jp6taMdaTdduol web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional pemwnent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Crffeda, DSB-89 and BCSII Building Component Col$#fatethbnp0ge 9vailable from Truss Plate Institute. 583 D'Onofrio Drive, h4odison, WI 53719. s�OsT E9�4/2�F9 10243 Q Z X O Q F VQ �Q� T C. ANO November 3,2004 7777 Greenback Lane I..i!V Suite 109 Citrus Heights, CA, 95610 M iTeke �J Job russ ss ype Qty Py R14144438 10146.04 B1GO DBL. HOWE 1 2 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MTek Industries, Inc. Wed Nov 03 13:36:30 2004 Page 2 LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: A-C=-84, C-E=84, A-E=-14 Concentrated Loads (lb) Vert: G=-1717(B)1=-4840(B) H=-1717(B) J=-1717(B) K=-1717(B) L=-1717(B) M=1717(B) N=1717(B) 0=1717(B) P=1717(B) 7777 Greenback Lane ®Verify design parametars and READ 11rOTES ON TffiS AND DYCLr1DED LQ7E8 REFSREHCE PAQS � 7473 BEFORE USE. Suite 109 � Design valid for use any with MTek connectors. This design is based only upon parameters shown, and is for on individual building component. Citrus Heights, CA, 95610 Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the ►esponsibillity of the erector. Additional permonent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII QuaMy Cdterla, DSB-89 and BCSII Building Compononf M �Tek` Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Job Truss ype Oty Ply R1414443 10146-04 C1 COMMON 1 1 .lob Reference (optional) BMC WEST (IDAHO FALLS). IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:12 20G4 Page 1 -2.0-0 6-8-0 13-4-0 15-4-0 2-0.0 6-8-0 6-8-0 2-0.0 Scale = 1:28.5 4x4 M1120= C I I M I� 8-8-0 13-4-0 6-8-0 6.8.0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.70 Vert(LL) -0.04 B-F >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.33 Vert(TL) -0.07 B-F >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.01 D n/a n/a BCDL 7.0 Code IRC2000/ANSI95 I (Simplified) Weight:41 lb LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 6-0-0 oc pudins. BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SPF Stud/Std REACTIONS (lb/size) B=825/0-3-8, D=825/0-3-8 Max HorzB=-101(load case 6) Max UpliftB=-383(load case 5). D=383(load case 6) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/38, B-C=-695/290, C-D=-695/290, D-E=0/38 BOT CHORD B-F=200/618, D-F=-200/618 WEBS C-F=-93/222 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard NAL 4Q��Q�GOST EO�•�F9 10243 o � o F T C. ANo November 3,2004 ®WARNING - 17erVy design parameters and READ NOTES ON TBIS AND DWJMED it TES REFERENCE PADS MU-7473 BEFORE US& 7777 Greenback Lane Deign valid for use only with MTek connectors. This design is based only upon parameters shown, and is for on individual building component. Suite 109 Applicability of design aromenters and proper incorporation of component is responsibility Citrus Heights, CA, 95610 pp ty ig p p p rpo p ponsibiGty of building designer -not buss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M �Tek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Job Truss 14W Typi 10146-04 1C1G COMMON R141 tD 83402 6.100 s Sep 17 2004 -24-0 6-8-0 , 13-4-0_ , 154-0 , 2-0-0 6-8-0 6-8-0 2-0-0 Scale = 1:28.5 LOADING (psf) SPACING 2-0-0 CSI TCLL 35.0 Plates Increase 1.15 TC 0.33 TCDL 7.0 Lumber Increase 1.15 BC 0.13 BCLL 0.0 Rep Stress Incr YES WB 0.05 BCDL 7.0 Code IRC2000/ANS195 (Matrix) LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E OTHERS 2 X 4 SPF Stud/Std 4x4 MI120= 13.4-0 I� DEFL in (loc) I/deft Ud PLATES GRIP Vert(LL) -0.06 1 n/r 120 MI120 197/144 Vert(TL) -0.07 1 n/r 120 Horz(TL) 0.00 H n/a n/a Weight: 49 Ib BRACING TOP CHORD Sheathed or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) B=376/13-4-0, H=376/13-4-0, L=170/134-0, M=214/13-4-0, N=152/13-4-0, K=214/13-4-0, J=152/13-4-0 Max HorzB=101(load case 6) Max UpliftB=-172(load case 5), H=191(load case 6), M=-94(load case 5), N=-20(load case 4), K=92(load case 6), J=20(load case 3) Max GravB=376(load case 1), H=376(load case 1), L=170(load case 1), M=221(load case 7), N=152(load case 1). K=221(load case 8), J=152(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/75, B-C=-85/58, C-D=-55/85, D-E=-57/109, E-F=57/102, F-G=-55/52, G-H=85/25, H-1=0/75 BOT CHORD B-N=0/90, M-N=0/90, L-M=0/90, K-L=0/90, J-K=0/90, H-J=0/90 WEBS E-L=149/0, D-M=180/95. C-N=-160169, F-K=180/94. G-J=161/69 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98: 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonooncurrent with any other live loads. 5) All plates are 1.5x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. ONAL LOAD CASE(S) StandardE�C�'j Q��C ISTF9� 2F�` 10243 o � 0 O OF �pPGQ� T C. A14 November 3,2004 vrrrrimavrr 7777 Greenback Lana A WARNDIrG - VEri(/}r design pasamatcrs and READ NOTES ON TSlS AND INCLrlDED At2TES PAGE ffiI t►473 BEFORE t7SE Suite 109 Design void for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Citrus Heights, CA, 95610 Appicobil ly of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibiity of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSIAP11 Qualify Criteria, DSB-89 and SCSI BuRding Component iTek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison. WI 53719. 10146-04 1 HF BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 QUEENPOST 2 1 Job Reference (optional) R1414444' 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 03 11:24:14 2004 Pagi 9.10-0 19-8-0 9-10-0 4x4 M1120= 9-10-0 Scale = 1:74.6 F 13.42 B A E 12 D C G H I J K O O T S R Q P 0 N M O L 3x4 M1120\\ 3x4 M1120// 19-8-0 19-8.0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (toe) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.10 Vert(LL) n/a - n/a 999 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.06 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.19 Horz(TL) 0.01 K n/a n/a BCDL 7.0 Code IRC20001ANS195 (Matrix) Weight 111lb LUMBER BRACING TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 6-0-0 oc pudins. BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt F-P, E-Q, G-0 REACTIONS (lb/size) A=94/19-8-0, K=94/19-8-0, P=123/19-8-0, Q=192/19-8-0, R=198/19-8-0, S=197/19-8-0, T=192/19-8-0, 0=192/19-8-0 , N=198/19-8-0, M=197/19-8-0, L=192/19-8-0 Max HorzA=-345(load case 3) Max UpliftA=-123(load case 3). K=72(load case 4), Q=137(load case 5), R=161(load case 5), S=-153(load case 5), T=-151(load case 5), 0=-133(load case 6), N=-163(load case 6), M=-153(load case 6), L=-151(load case 6) Max GravA=298(load case 5). K=269(load case 6), P=220(load case 6), Q=200(load case 7), R=198(load case 1), S=197(load case 7), T=192(load case 1), 0=200(load case 8). N=198(load case 1), M=197(load case 8), L=192(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension T_ OP CHORD A-B=-414/186, B-C=-291/173, C-D=196/156, D-E=-116/144, E-F=-113/198, F-G=-113/173, G-H=-116/101, H-1=-127/87, I-J=-250/104, J-K=-376/117 BOT CHORD A-T=-78/279, S-T=-78/279, R-S=-78/279, Q-R=78/279, P-Q=78/279, O-P=78/279, N-0=-78/279, M-N=-78/279, L-M=78/279, K-L=78/279 WEBS F-P=203/0, E-Q=-172/154, D-R=169/177, C-S=170/173, B-T=-157/155, G-0=-172/150, H-N=-169/179, I-M=170/172, J-L=157/155 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. LOAD CASE(S) Standard °'ScaOSTF9 �'�QF Q � F F \TO F c`OA Py 9r C. AN��c November 3,2004 ® WARMNG - Perib design parameters and READ NrOT= ON IM AND DPCLUDED WTEK REFERENCE PAGE AM 7473 BEFORE USE. 7777 Greenback Lane i ® Design valid for use only with MTek connectors. This design is based only upon parameters shown, and a for an individual building component. Suite 109 Applicability of design paromentess and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsbiBty of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consull ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Compoent M �Tek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Job Truss 11M Type Qty Ply 'qmF R1414444 10146-04 J1 MONO TRUSS 25 1 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:15 2004 Page 1 -2-0.0 8.0.0 , 2-0.0 B 0.0 1.5x4 M1120 11 Scale = 1:28.3 C 13 LOADING(psf) SPACING 2-0-0 TCLL 35.0 Plates Increase 1.15 TCDL 7.0 Lumber Increase 1.15 BCLL 0.0 Rep Stress Incr YES BCDL 7.0 Code IRC2000/ANSI95 LUMBER TOP CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E WEBS 2 X 4 SPF Stud/Std 112011 8.0-0 B-0.0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TC 0.91 Vert(LL) 0.21 B-D >427 240 M1120 197/144 BC 0.41 Vert(TL) -0.32 B-D >284 180 WB 0.00 Horz(TL) 0.00 n/a n/a (Matrix) Weight: 26 lb REACTIONS (lb/size) B=595/0-5-8, D=345/0-5-8 Max HorzB=223(load case 5) Max Uplift6=-274(load case 5), D=-203(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/77, B-C=-161/105, C-D=-291/149 BOT CHORD B-D=0/0 BRACING TOP CHORD Sheathed or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard 4Q�FQ�G �S TE 10243 qr PLO 0� 1 F OF C. AN4 November 3,2004 ,..,,..,® ® GDARMNG • 9tft design pararrrctcrs and READ ROTES ON THIS AND lNCLaDEMIT ER TER REFERENCE PAGE ffi17473 BEFORE USE 7777 Greenback LaneSuite 109 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Citrus Heights, CA, 95610 Applicability of design paromenters and proper incorporation of component a responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additionol temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DS"9 and BCSI1 Building Component M �ek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 10146-04 I J1A I MONO TRUSS 16 I 1 .lob Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Nov 0311:24:16 2004 Page 1 A -2-0-0 5.11-11 I I ' 2-0.0 5.11-11 � 5-11-11 5-11.11 Scale = 1:19.6 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.42 Vert(LL) 0.07 B-D >987 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.23 Vert(TL) -0.11 B-D >658 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight: 17lb LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 5-11-11 oc purlins. BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) C=198/Mechanical, B=498/0-3-8, D=40/Mechanical Max Horz B=1 79(load case 5) Max UpliftC=98(load case 5), B=-240(load case 5), D=-410oad case 3) Max GravC=198(load case 1), B=498(load case 1), D=98(load case 2) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/76, B-C=-125/70 BOT CHORD B-D=0/0 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft TCDL=4.2psf, BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. LOAD CASE(S) Standard NAL �FSS��STFq FF9 10243 I O O of �o � T C. 0 November 3,2004 ® WARNING - ver ft design parwneters and READ NOTES ON TMS AND MCLODED M T K REFERENCE PAGE AW 7473 BEFORE US& 7777 Greenback Lane ® it Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Sue 109 Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTek` Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison. WI 53719. R14 10146-04 I J1 B I MONO TRUSS BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 A 6 1 l Job Reference (optional) 6.100 s Sep 17 2004 MiTek industries, Inc. Wed Nov 03 11:24:17 2004 Page 1 , -2-0-0 3-11-11 , 2-0-0 3-11-11 „ Scale = 1:15.0 r 3.11-11 , 3-11-11 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.38 Vert(LL) 0.01 B-D >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.10 Vert(TL) -0.02 B-D >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 12lb LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 3-11-11 oc pudins. BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc'bracing. REACTIONS (lb/size) C=94/Mechanical, B=420/0-3-8, D=26/Mechanical Max Horz B= 1 38(load case 5) Max UpliftC=39(load case 5), B=-218(load case 5), D=-27(load case 3) Max GravC=94(load case 1), B=420(load case 1). D=64(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/76, B-C=-98/30 BOT CHORD B-D=0/0 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. LOAD CASE(S) Standard QGOSTE 10243 � o of T C. A November 3,2004 A ,..�,..,® fVARHRVO - IIer(Jy design parameters and READ ROTES ON TSIS AND Iltrfll7DED ffiTES REFERENCE PAGE e� 7777 Greenback Lane 7473 BEFORE USE. Suite 109 Design void for use only with Mr1ek connectors. This design is based any upon parameters shown, and is for an individual building component. Citrus Heights, CA, 95610 Applicability of design poromenters and proper incorporation of component is responsibility of building designer - not inns designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillily of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPl1 Quality Criteria, DSB-89 and BC511 Building Component M �Tek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Job Truss IqW/Type Qty Ply 10146-04 J1 C MONO TRUSS 6 1 Job Reference (optional) BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed -2-0.0 1-11-11 2-0.0 1-11-11 A 1-11-11 , R 1414444 17 2004 Page 1 Scale = 1:10.5 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.34 Vert(LL) -0.00 B >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.03 Vert(TL) -0.00 B-D >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 7.0 Code IRC2000/ANSI95 (Matrix) Weight 7 ib LUMBER BRACING TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Sheathed or 1-11-11 oc pudins. BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) C=17/Mechanical, B=366/0-3-8, D=14/Mechanical Max HorzB=100(load case 5) Max UpliftC=17(load case 1), B=-212(load case 5), D=-14(load case 3) Max GravC=30(load case 5), B=366(load case 1), D=33(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/75, B-C=-83/13 BOT CHORD B-D=0/0 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. LOAD CASE(S) Standard oFF�'ScaOSTER 10243 qT Pao 0 of T C. M4 November 3,2004 ® WAWMM - Ver(& design parasneters and READ NOTES ON THIS AND DI1 VDSD SIITEK REFERENCE PAGE AW 7473 BEFORE OS& 7777 Greenback Lane .�.r...® Design valid for use only with MTek connectors. This design is based any upon parameters shown, and is for on individual building component. Suite 109 Applicability of design poramanten and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M �Tek� Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive. Madison, WI 53719. Job 10146-04 I K1 HJ R14 -2-9-15 6-5-0 11-3-12 2-9-15 6.5-0 4-10-12 SKH26R SKH26R SKH26R 6-5-0 11-3-12 6.5-0 4-10-12 Nov 03 11:24:19 2004 Page 1 3x4 M1120 !:�- Scale = 1:29.0 E LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.90 Vert(LL) -0.18 B-F >719 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.35 Vert(TL) -0.29 B-F >436 180 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(TL) 0.01 F n/a n/a BCDL 7.0 Code IRC2000/ANS195 (Matrix) Weight: 51lb LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 6 DF 180OF 1.6E WEBS 2 X 4 SPF 165OF 1.5E -Except' C-F 2 X 4 SPF Stud/Std REACTIONS (lb/size) F=748/Mechanical, B=919/0-7-12 Max HorzB=229(load case 3) Max UpliftF=-419(load case 3), B=-427(load case 3) BRACING TOP CHORD Sheathed or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=0/86, B-G=-980/306, G-H=-828/325, C-H=805/314, C-1=209l77, D-1=-94/29, D-E=-9/0, D-F=-289/150 BOT CHORD B-J=-398/845, J-K=-398/845, K-L=-398/845, F-L=-398/845 WEBS C-F=-826/367 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Use USP SKH26L (With 16d nails into Girder & NASD nails into Truss) or equivalent spaced at 2-9-15 oc max. starting at 2-10-4 from the left end to 8-6-2 to connect truss(es) J I C (1 ply 2 X 4 SPF) to front face of bottom chord. 5) Use USP SKH26R nth 16d nails into Girder & NASID nails into Truss) or equivalent spaced at 2-9-15 oc max. starting at 2-10-4 from the left end to 8-6-2 to connect truss(es) J I C (1 ply 2 X 4 SPF) to back face of bottom chord. 6) Fill all nail holes where hanger is in contact with lumber. 7) Special hangers) or other connection device(s) shall be provided sufficient to support concentrated load(s)101b down and 241b up at 5-8-3. 101b down and 241b up at 5-8-3, 1141b down and 821b up at 8-6-2, 1141b down and 821b up at 8-6-2, and 2811b down at 2-104, and 281b down at 2-10-4 on top chord. The design/selection of such special connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert A-D=84, D-E=84, B-F=14 Concentrated Loads (lb) Vert H=20(F=10, B=-10)1=-229(F=-114, 8=-114) J=1(F=O, B=0) K=-25(F=12, B=-12) L=-53(F=-26, B=-26) QQ�FQ��ONAL S TE IV%9 10243 0 tom. 9�F OF Q �Q� '4T C ANO November 3,2004 ® WAS% Ter (RJn Parameters and READ lYOTSS QH T211SS AND l2lfCZrJDED ?*IITES REFER8IVCE PAGE ffif 7473 BEFORE r1SL 7777 Greenbadc Lane . !I& 09 Design valid for use only with M iTek connectors. This design is based only upon parameters shown, and is for an individual budding component. Suitt He Appicabirity of design peramenters and proper incorporation of component a responsibility of building designer - not truss designer. Bracing shown Citrus Heights, CA 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, guoity control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB•89 and SCSI Building Component iTek` Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive. Mad'aon. WI 53719. 10146-04 I V1 4 4 0 VALLEY 1 1 6.100 s 3-5.8 , 6-11-0 3.5.8 3-5.8 4x4 M1120= B 3x4 MI120 5- 1.5x4 M112011 3x4 MI120-Z� LOADING (psf) SPACING 2-0-0 CSI TCLL 35.0 Plates Increase 1.15 TC 0.08 TCDL 7.0 Lumber Increase 1.15 BC 0.04 BCLL 0.0 Rep Stress Incr YES WB 0.05 BCDL 7.0 Code IRC20001ANSI95 (Simplified) LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E OTHERS 2 X 4 SPF Stud/Std REACTIONS (lb/size) A=155/6-11-0, C=155/6-11-0, D=253/6-11-0 Max HOrzA=-26(load case 6) Max UpliftA=-38(load case 5), C=-43(load case 6), D=33(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD A-B=31/31, B-C=-31/21 BOT CHORD A-D=1/28, C-D=1/28 WEBS B-D=-213/58 } L R 1414444 Wed Nov 03 11:24:20 2004 Page 1 DEFL in (loc) I/deft Ud PLATES GRIP Vert(LL) n/a - n/a 999 M1120 197/144 Vert(TL) n/a - n/a 999 Horz(TL) 0.00 C n/a n/a Weight: 17 lb BRACING TOP CHORD Sheathed or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Gable requires continuous bottom chord bearing. LOAD CASE(S) Standard Scale=1:14.3 NAL oF`�S GOSTEgN��2 QQ Q� FO �F9 10243 '9T C Off' OF T C. AV4 November 3,2004 A WAWMG - Verft design parameters and READ NOTES ON MS AND INCLUDED A! = REFFJMW PAGE MU-7473 BEFORE USE. 7777 Greenback Lane Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual budding component. Suite 109 Applicability of design paromenters and proper incorporation of component is responsibility of building designer - not inns designer. Bracing shown Citrus Heights, CA, 95610 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibilkty, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding Fabrication. quality control, storage. derrvery, erection and bracing, consult ANSI/IPII Quality Criteria, DSB-89 and BCSII Building Component M Me ke Safety Information available from Truss Plate Institute, 583 D'Onofdo Drive, Madison, WI 53719. k Symbols PLATE LOCATION AND ORIENTATION 14-1 3/4' *Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0-'/i6' from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. *Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 x 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI I : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS o C 1-2 C2-3 c 4 WEBS O= ap U ice' U CL �Ab U O ~ C7-8 C6.7 CS-6 bUI IUM UIUKUJ 8 7 6 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A MEMO MiTek Engineering Reference Sheet: MII-7473 General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 p 4. Cut members to bear tightly against each other. 0- 5. Place plates on each face of truss at each p joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 5 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. ® 2004 MiTek® 0