Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SHORT FORM - 05-00041 - 587 Johnson St - New SFR
`;v short corm •r Entire House Job: Job4 Date: Feb 16, 2005 By: Blair Singleton For: Trent Harris Rexburg, ID 83440 Phone:3517857 Design• • Htg Clg Infiltration Outside db (OF) -6 89 Method Simplified Inside db (OF) 70 75 Construction quality SemFtight Design TD (OF) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/Ib) -31 HEATING EQUIPMENT Make AmStd Trade Freedom 90 Single Stage Model AUX080C960D' Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 80000 Btuh 76000 Btuh 56 OF 1467 cfm 0.031 cfm/Btuh 0.80 in H2O COOLING EQUIPMENT Make AmStd Trade Standard 10 Cond 2A7B0048A1 Coil CCBC48A4AC Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 10 SEER 30800 Btuh 13200 Btuh 44000 Btuh 1467 cfm 0.051 cfm/Btuh 0.80 in H2O 1.00 ROOM NAME Area ff) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Master Bath 238 4710 2850 146 147 Family Room 909 11182 2159 346 111 Bed 4 156 3616 2002 112 103 Bath 2 114 1142 397 35 20 Bed 5 154 3264 1990 101 102 Master Bed 196 3694 1976 114 102 Bed 3 154 4201 1736 130 89 bath 130 0 0 0 0 Bed 2 156 5143 3144 159 162 Kitchen/Diming 420 4697 8453 145 435 Living Room 316 5574 3674 172 189 I lAlil.. o....— an OI n � A n o I Printout certified by ACCA to meet all requirements of Manual J 8th Ed. A wnghtsoft RightSude Resiclenhal6.0.02R615 SR4020a5-Feb28003245 ACC,+ . C Wy DDcumemslW nghlsot WAQTrent Hams Lnp Calc= MJ8 Onentabm = N Page 1 Entire House Other equip bads Equip. @ 0.94 Latent cooling TOTALS RSM I 3023 I 21673 33992 28520 1467 1467 0 3023 ' 69145 ' 30562 ' 1467 ' 1467 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. WrjghtSOfC RightSede ResWenbA6.0.02RSR40615 2005-Feb260032:45 ACCkC:\MytbcumentsWJrightsaftWAQTmrRHams l_np Cat =MJ8 Orientattn=N Page Building Analysis j` Entire House For: Location: Idaho Falls, ID US Efevation: 4'/4i ft Latitude: 44°N Outdoor: Dry bulb (°F) Dai range F) We bulb (° Wind speed (mph) Project Information Trent Harris Rexburg, ID 83440 Phone:3517857 Heating Cooling 89 - 60 (H ) 15.0 7.5 Component Btuh/ft' Btuh % of load Wags 5.3 11826 17.1 Glazing 35.7 7608 11.0 Doors 27.4 1149 1.7 Ceiings 2.0 3339 4.8 Floors 1.5 2026 2.9 Infiltration 2.2 4193 6.1 Ducts 17330 25.1 Piping 0 0.0 Humidification 0 0.0 Ventilation 21673 31.3 Adjustments -0 Total 69145 100.0 Job: Job4 Date: Feb 16, 2005 By: Blair Singleton Indoor. Indoor temperature(°F) Design TD C� Relative humidtty (%) Moisture difference (gr/lb) Heating 70 76 50 61.5 Cooling 75 14 50 -31.5 Infiltration: Method Construction quality Simplified SemiLtight Fireplaces 0 Cooling- __- -- - -- -- --- --_I Component Btuh/ft' Btuh % of load Wags 0.3 640 2.0 Glazing 28.1 5975 18.4 Doors 6.7 280 0.9 Ceilings 1.1 1845 5.7 Floors 0.0 0 0.0 Infiltration 0.2 407 1.3 Ducts 11864 36.5 Ventilation 3992 12.3 Internal gains 7510 23.1 Blower 0 0.0 Adjustments 0 Total 32513 100.0 Overall U-value = 0.059 Btuh/ft'--'F Data entries checked. G.", Wr10h1tS0ft RightSuite Residenbal6.0.02RSR40615 2005-Feb-2800:32:45 CAMy DocurrentsUrightsoft HVACITrent Harris 1.rrp Calc= M38 Onentadon = N Page 1 Component Constructions Entire House For: Trent Harris Rexburg, ID 83440 Phone:3517857 Job: Job4 Date: Feb 16, 2005 By: Blair Singleton Location: Indoor: Heating Cooling Idaho Fails, ID, US Indoor temperature (OF) 70 75 Elevation: 4741 1t Design TD (OF) 76 14 Latitude: 44% Relative humidity (e/u 50 50 Outdoor: Heating Cooling Moisture difference gr/lb) 61.5 -31.5 Dry bulb CF) -6 89 Infiltration: Daily range (OF) - 34 ( H) Method Simplified Wet bulb (OF) - 60 Construction quality SemFtight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area 11-value Insul R HIA HTM Loss Clg HrM Gain (e•) (Build'-F) (2LF9w (Mft ) tablr) (MAL" tatuh) Walls 15B13-0wo-4: Basement - 8" concrete, wood framing, interior finish, n 448 0.059 13.0 5.68 2546 0.11 50 R-13 cavity, no board insulation, 4' a 272 0.059 13.0 5.62 15M 0.11 29 s 240 0.059 13.0 5.78 1386 0.12 29 w 184 0.059 13.0 5.78 1063 0.12 22 all 1144 0.059 13.0 5.70 6525 0.11 131 12F-Osw. Wood stud frame, siding orstuoco, no board insulation, n 388 0.065 21.0 4.94 1917 0.47 184 R-21 cavity Insulation a 330 0.065 21.0 4.94 1630 0.47 157 s 183 0.065 21.0 4.94 904 0.47 87 w 172 0.065 21.0 4.94 850 0.47 82 all 1073 0.065 21.0 4.94 5301 0.47 509 Partitions (none) Windows 4A1-2ov: Operable, vinyl frame, low-e glass, e=0.20 surface 2, 2 pane Doors 11 PM: Metal door, fiberglass core, with storm Ceilings 16B-3aad: Ceiling under vented attic, no radiant harrier, dark shingles, R-38 insulation Floors 21A-32c: Carpeted basement floor, No insulation, 32' wide n 32 0.470 0.0 35.7 1143 15.9 508 n 71 0.470 0.0 35.7 2536 15.9 1128 e 32 0.470 0.0 35.7 1143 52.4 1678 e 6 0.470 0.0 35.7 214 52.4 315 s 60 0.470 0.0 35.7 2143 28.6 1717 w 12 0.470 0.0 35.7 429 52.4 629 all 213 0.470 0.0 35.7 76D8 28.1 5975 n 21 0.360 0.0 27.4 575 6.66 140 s 21 0.360 0.0 27.4 575 6.66 140 au 42 0.360 0.0 27.4 1149 6.66 280 1690 0.025 38.0 1.98 3339 1.09 1845 1333 0.020 0.0 1.52 2026 0.00 0 wnghtsoft RlghtSufte Residential6.0.02RSR40615 2005-Feb�2800:32:45 ACGA CAMy WcumenlsWvrightsa WAQTmnt Hams t.ap Caic= MJ8 Orientation = N Page 1 Project Entire House Job: Job4 Date: Feb 16, 2006 By. Blair Singleton Project tnformatian For: Trent Harris Rexburg, ID 83440 Phone:3517857 Notes: Weather: Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TO 76 OF Heating Summary Structure 30142 Btuh Duds 17330 cfm Central vent (309 cfm) 21673 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 69145 Btuh Infiltration Idaho Falls, ID, US Method Simplified Construction quality SemHght Fireplaces 0 Heating Cooling Area (ft2) 3023 3023 Volume (fta) 18852 18852 Air changes/hour 0.19 0.10 Equiv. AVF (cfm) 60 31 Heating Equipment Summary Make AmStd Trade Freedom 90 Single Stage Model AUX080C960D Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 80000 Btuh 76000 Btuh 56 OF 1467 cfm 0.031 cfm/Btuh 0.80 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TO 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Sensible Cooling Equipment Load Sizing Structure 16656 Btuh Duds 11864 Btuh Central vent (309 cfm) 3992 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 30562 Btuh Latent Cooling Equipment Load Sizing Structure 2835 Btuh Ducts -429 Btuh Central vent cfm) -5549 Btuh �309 Equipment la ent bad 0 Btuh Equipment total load 30562 Btuh Req. total capacity at 0.70 SHR 3.6 ton Cooling Equipment Summary Make AmStd Trade Standard 10 Cond 2A7130048A1 Coil CCBC48A4AC Efficiency Sensible cooing Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 10 SEER 30800 Btuh 13200 Btuh 44000 Btuh 1467 cfm 0.051 cfm/Btuh 0.80 in H2O 1.00 Printout cerfified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft RightSuite Resioental6.0.02RSR40615 2005-Feb2800:32,45 .% ,CP, C Ahy Documents\W rig6tsoft WACTrent Harris l.rrp Cale= MJ8 Orientabon = N Page 1 Right-J'Worksheet -- Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name Enfire House Master Bath 2 Exposed wall 309.0 0 31.0 It 3 Ceiling height 8.0 0 &0 It heat/cool 4 Roomdimensions 14.0 x 17.0 It 5 Room area 3023.0 if 238.0 fF Ty Construction U-value Or HTM Area (IF) Load Area (�) Load number I (Bluh/ffL.F) (Bluh/ff) or Perimeter 00 (Bluh) or Perimeter (f) (Btuh) Heat Cool Grins HIPS Heat Cool Gross WP/S Heat I Cool 6 Vi/ 15813-0w 4 0.093 n 4.48 0.24 480 "a 2546 50 0 0 0 0 t-O 4A7-2ov 0.470 n 35.72 15.88 32 0 1143 608 O 0 0 0 12F-0sw 0.065 n 4.94 0.47 480 388 1917 184 112 100 494 47 4A1-2ov 0.470 n 35.72 15.88 71 0 2536 1128 12 0 429 191 11 11KO M360 n 27.36 ass 21 21 675 140 0 0 0 0 1q/ 15813-0ac4 0.093 a 4.48 0.24 304 272 1530 29 0 0 0 0 `C 4A1-2w 0.470 a 35.72 52.43 32 0 1143 1678 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 336 330 1630 157 0 0 0 0 L-C 4A1-2w 0.470 a 35.72 52.43 6 0 214 315 0 0 0 0 W 15B13-(hvc4 0.093 s 4.48 0.24 240 240 1386 29 0 0 0 0 Vj/ 12F-0sw 0.065 s 4.94 0.47 264 183 904 87 0 0 0 0 4A1-2w 0.470 s 35.72 28.62 60 0 2143 1717 0 0 0 0 II----GD 11KO 0.360 s 27.36 6.66 21 21 575 140 0 0 0 0 W 15813-0wc4 0.093 w 4.48 0.24 184 184 1063 22 0 0 0 0 1Y 12F-0ew 0.065 W 4.94 0.47 184 172 850 82 136 124 613 59 t-i 4A1-2w 0.470 w 35.72 52.43 12 0 429 629 12 0 429 629 C 16B38ad 0.026 - 1.98 1.09 1690 1690 3339 1845 238 238 470 260 F 21A32c 0.020 - 1.52 0.00 1333 151 2026 0 0 0 0 0 6 c)AED emursion 0 1 194 Envelope lomIgain 25949 8740 2434 1380 12 a) Infiltration 4193 407 557 54 b) Room ventilation 0 0 0 0 13 Internal gairs: O=Upams@ 230 17 3910 1 230 Appliances® 1200 3 3600 0 0 Less e#emal fool 0 0 0 0 Lesstransfer 0 0 0 0 Redishibuticn -0 0 0 0 14 Subtotal 30142 16656 2991 1664 15 Duct bads 57% 71% 1 17330 1 11864 57% 71% 1720 1185 Total mom load 1 47472 285M 4710 2850 Air required (ctm) 1467 1467 1 1 146 147 Printout certified by ACCA to meet all requirements of Manua I J 8th Ed. A& wrtghtsoft RWSuite Residential6.0.02RSR40615 2005-Feb2800:32:45 C:1My DocumentslW nghtso0 HVAQTrent Harris t.rrp Cak - MJ6 Orientation = N Page 1 Right-i-Worksheet _ Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name Family Roan Bed 4 2 Exposed wall 87.0 It 29.0 0 3 Ceiling WON 8.0 It heWcool 8.0 f1 heat/cool 4 Room dimensions 1.0 x 909.0 0 13.0 x 12.0 It 5 Rcom area 909.0 fF 156.0 fR Ty Construction U- lue Or HTM Area (r Load ad Area (f) Load number I (Btuh/ft-'F) (Btuh/ff) or perimeter (Q (Bluh) or perimeter QQ (Bluh) Heat Cool Gross N/P/8 Heat Cool Gross WP/S Heat Cool 6 W 15813-0wcA 0.093 n 4.48 0.24 392 360 2038 40 0 0 0 0 t_ 4A1-2ov 0.470 n 35.72 15.88 32 0 1143 WO 0 0 0 0 %J 12F-Osw 0065 n 4.94 0.47 0 0 0 0 0 0 0 0 �C 4A1-2w 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 �D 11 K0 0.360 n 27.36 6.66 0 0 0 0 0 0 0 0 W 15813Avc-4 0.093 a 4.48 0.24 16 16 92 2 96 80 441 8 L-G 4A7-2(N 0.470 a 35.72 52.43 0 0 0 0 18 0 572 839 12F-Oiw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 Y-(' 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15B134)wc4 0.093 s 4.48 0.24 136 136 786 16 104 104 601 13 12F41sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 4A1-2ov 0.470 s 35.72 28.62 0 0 0 0 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 W 1581341ac4 0.093 w 4.48 024 152 152 878 18 32 32 185 4 ltV 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 I-1' 4A1-2cv 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16638ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 21A32c 0.020 - 1.52 0.00 909 87 1382 0 156 29 237 0 6 c)AEDemursion -90 51 Envelope loss/gain 6319 495 2036 914 12 a) InfiXration 781 76 260 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupantso 230 3 ON 1 230 Appliances@ 1200 0 0 0 0 Lew erdemal bad 0 0 0 0 Lewhansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 7100 1261 2296 1169 15 Duct bads 57% 71% 4082 898 57% 71% 1320 833 Total room bad 11182 2159 3616 2002 Air required (cfm) 346 111 112 103 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr7gFlt50R RightSuite Restlentia18.0.02RSR40615 2006-Feb-2800:32:45 C:1W Oocumen[alWrightso8 WAQTmnt Harris t.rrp Calc=MJ8 Onentaton=N Page Right-7Worksheet Job: Job4 Entire House Date: Feb 16, 2006 .� By: Blair Singleton 1 Room name Bath 2 Bed 5 2 Exposed wall 10.0 ft 25.0 it 3 Ceiling height 8.0 It heat/cool 8.0 it heat/cool 4 Room dimensions 1.0 x 114.0 ft 11.0 x 14.0 ft 5 Room area 114.0 fF 154.0 if Ty Construction U-value Or HTM Area (fF) Load Area (W) Load number (Bluh/fP--°F) (Bluh/ff) cr perimeter (to (Btuh) a perimeter (fl) (Bluh) Heat Cool Gross NIPS Heat Cool Gross WP/S Heat Cool 6 W 15613-OweA 0.093 n 4.48 0.24 0 0 0 0 88 88 508 11 �-O 4Ai-2r 0.470 n 35.72 15.68 0 0 0 0 0 0 0 0 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 4A7-2ov 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 it KO 0.360 n 27.36 6.66 0 0 0 0 0 0 0 0 UI/ 15613-Owc-4 0.093 a 4.48 0.24 80 80 462 10 112 96 534 10 _C 4AI-2ov 0.470 a 35.72 52.43 0 0 0 0 16 0 572 839 y/ 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 --C 4A1-2ov 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15B13-Owc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 4A1-2ov 0.470 s 35.72 28.62 0 0 0 0 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 W 15B13-0wc-1 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 ILO12F-Osw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 4A1-2ov 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 166-38ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 21 A-32c 0.020 - 1.52 0.00 114 10 173 0 154 25 234 0 6 c)AED excursion -16 51 Envelope loss/gain 635 -7 1848 910 12 a) Infiltration 90 9 224 22 b) Room venfilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 1 230 Appliances@ 1200 0 0 0 0 Lessexternal load 0 0 0 0 Lesstmnsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 725 232 2072 1162 15 Duct loads 57% 71% 417 165 57% 71% 1191 828 Total room load 1142 397 3264 1990 Air required (cfm) 35 20 101 1()2 Printout cerfified by ACCA to meet all requirements of Manual J 8th Ed. wllght501`t Right -Suite Residential 6 0.02 RSR40615 2005-Feb-28 00:32.45 sCr-I' C:Wy Documenrs\WnghRot HVACITrent Hams l.np Calc = MJ8 Onentabon = N Page 3 Right-.rWorksheet °tx eba DF ate: Fe Entire House Db 16, zoos By: Blair Singleton 1 Room name Master Bed Bed 3 2 Exposed wall 18.0 it 25.0 a 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 14.0 x 14.0 R 11.0 x 14.0 fl 5 Room area 196.0 fe 154.0 fF Ty Construction U-value Or HTM Area (fn Load Area of) Load number I (Btuh/ff2F) (Bluh/ff) or perimeter (ff) (Bluh) or perimeter Of) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W 15B13-0wc4 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 _ 4A1-2ov 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 12F Osw 0.065 n 4.94 0.47 112 82 405 39 88 68 336 32 4A1-2w 0.470 n 35.72 15.88 30 0 1072 477 20 0 714 318 11 IIKO 0.360 n 27.36 6.66 0 0 0 0 0 0 0 0 V)/ 15813-Owc4 0.093 a 4.48 0.24 0 0 0 0 0 0 0 0 �C 4A1-2od 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W/ 12F-Osw 0.065 a 4.94 0.47 16 16 79 8 112 112 553 53 Y-C 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 w 15813-0wc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 1qJ 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 IL --CD' 4A1-2av 0.470 s 35.72 28.62 0 0 0 0 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 w 15813-0xc4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 12F-0ew 0.065 w 4.94 0.47 16 16 79 8 0 0 0 0 4A1-2ov 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 196 196 387 214 154 154 304 168 F 21A-32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AE D excursion -82 -56 Envelope loss/gain 2022 663 1908 515 12 a) Infiltration 323 31 449 44 b) Roomvenfilation 0 0 0 0 13 Intemalgains: Occupards@ 230 2 460 1 230 Appliances@ 1200 0 0 0 0 Less external bad 0 0 0 0 Lessmansfer 0 0 0 0 Redistribution 0 0 311 225 14 Subtotal 2345 1154 2667 1014 15 Duct loads 57% 71% 1348 822 57% 71% 1534 722 Total room load 3694 1976 4201 1736 Air required(cfm) 114 102 130 89 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft Right -Suite Res0ental6.0.02RSR40615 2005-Feb-2800:3245 C?.61y tbcumems\wnghlsoft HVAQTmnt Hams l.rrp Calc = MJ8 Orientation = N Page 4 Right=zrWorksheet Job: Job4 Entire House Date: Feb16,2005 By: Blair Singleton 1 Room name bath Bed 2 2 Exposed wall 10.0 it 29.0 it 3 Coiling height 8.0 fl halt/cool go, fl heaticool 4 Rcom dimensions 13.0 x 10.0 it 13.0 x 12.0 it 5 Room area 130.0 if 156.0 tF Ty Construction U- Iue Or HTIA Arm OF) Load Area (fF) Load number (Btuh/fR-•F) (Btuh/ff-) a perimeter (f9 (Btuh) or perimeter (f0 (81uh) Heat Cool Gloss WKS Heat Cool Gross WP/S Heat Cool 6 W 15B13-0wc4 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 �O 4A1-2w 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 W 12F-0•.w 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 4Al-2w 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 II--GD 11 KO 0.360 n 27.36 ass 0 0 0 0 0 0 0 0 Y1/ 15B13-0wc-4 0.093 a 4.48 0.24 0 0 0 0 0 0 0 0 �--G 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 V7! 12F-0sw 0.065 a 4.94 0.47 80 74 366 35 96 96 474 46 I-C W-2w 0.470 a 35.72 52.43 6 0 214 315 0 0 0 0 W 15B13-0wc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 yll 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 104 74 366 35 ��CD 4A1-2w 0.470 s 35.72 28.62 0 0 0 0 30 0 1072 659 IIKO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 w 15813-0wo4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 11Y 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 32 32 158 15 �-G 4A1-2w 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16B38ad 0.026 - 1.98 1.09 130 130 257 142 156 156 308 170 F 21A32C 0.020 - 1.52 O.OD 0 0 0 0 0 0 0 0 6 c)AED excursion -2 165 Envelope loss/gain 837 489 1 2378 1290 12 a) Infiltration 180 17 521 50 b) Room wntfilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 1 230 Appliances@ 1200 0 0 0 0 Less external bad 0 0 0 0 Lesstmrafer 0 0 0 0 Redistribution -1016 -737 367 266 14 Subtotal 0 0 3265 1836 15 Duct bads 57% 71% 0 0 57% 71%1 1878 1308 Total room bad 0 0 5143 3144 Air required (crm) 0 0 159 162 Printout cerfified by ACCA to meet all requirements of Manual J 8th Ed. wP4ght50R Right -Suite Residenta16.0.02RSR40615 2005-Fe62800:32:45 C:1My DocumentslWnghtsolt HVAQTmnt Hams t.np Cab=MJS Orientabon=N Page Right-i-Worksheet Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name IGbhm/Dining Living Room 2 3 Exposed wall Ceiling height 21.0 ft 8.0 8 heeVccol 24.0 1t 8.0 8 hesUcool 4 Roomdimensions 1.0 x 420.0 0 1.0 x 316.0 It 5 Roomarea 420.0 fF 316.0 if Ty Construction U-value Or HTM Area (ff� Load Area (if) Load number I (Bluh/ff'F) (Btuh/fF) or perimeter (M Pun) or perimeter (fq (Btuh) Heat Cool Gross MRS Heat Cool G. WP/S Heat Cool 6 W 15B134=-4 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 4A7-2ov 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 12F-0sw 0.065 n 4.94 0.47 168 138 682 65 0 0 0 0 4A7-2ov 0.470 n 35.72 15.88 9 0 321 143 0 0 0 0 11 11K0 15B13-0wc-4 0.360 0.093 n a 27.36 4.48 &66 0.24 21 0 21 0 576 0 140 0 0 0 0 0 0 0 0 0 W �G 4A1-2ov 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 32 32 158 15 �C 4A1-2ov 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 158134hvc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 ILZ12F41sw 0.065 s 4.94 0.47 0 0 0 0 160 109 538 52 4A7-2ov 0.470 s 35.72 25.62 0 0 0 0 30 0 1072 859 11KO 0.360 s 27.36 6.66 0 0 0 0 21 21 575 140 W 1581341wc4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 1p/ 12F-Osw 0.065 W 4.94 0.47 0 0 0 0 0 0 0 0 ---C 4A1-2ov 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16B38ad 0.026 - 1.98 1.09 420 420 830 459 316 316 624 345 F 21A32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 340 131 Envelope losstgain 2408 467 2967 1542 12 a) Infiltration 377 37 431 42 b) RoomvmUlation 0 0 0 0 13 Intemal gains: Occupards@ 230 3 690 2 460 Appliances@ 1200 3 3600 0 0 Less wdi real bad 0 0 0 0 Lesstrsnsfer 0 0 0 0 Redistribution 198 143 141 102 14 Subtotal 2982 4936 3539 2148 15 Duct bads 57% 71% 1715 3516 57% 71% 2035 1528 Total room bad 4697 8453 5574 3674 Air required (cfm) 145 435 172 189 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. we'7gF1t5471fi Right-Sude Residentai6.0.02RSR40615 2005-Feb-2800:32:45 '4'-Cl', CAW LbcumentslWughtsoB WAOTrent Harris Imp Cab=MJ8 Orientabon=N Page Right-c-Worksheet Job: Job4 Enure House Date: Feb 16, 2006 By: Blair Singleton 1 Room name Utility Roam 2 Exposed wall 0.0 ft 3 Ceiling height 8.0 It heat/ccol 4 Room dimensions 10.0 x 8.0 it 5 Room area 80.0 fF Ty Construction U-value Or HTM Arm (fF) Load Area Load number (Bluh/fR'F) (BtuhM or perimeter (fq (Bluh) or perimeter Heat Cool Grass WP/S Heat Cool Goss WKS Heal Cool 6 156134M-4 0.093 n 4.48 0.24 0 0 0 0 4A7-2ov 0.470 n 35.72 15.88 0 0 0 0 W 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 D 4A1-2w 0.470 n 35.72 15.88 0 0 0 0 11 IIKO 0.360 n 27.36 6166 0 0 0 0 l9/ 15B13-0Nc-4 0.093 a 4.48 0.24 0 0 0 0 T-G 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 Y-C 4A1-2w 0.470 a 35.72 52.43 0 0 0 0 IN 15B13-Owc-4 0.093 s 4.48 0.24 0 0 0 0 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 4A1-2w 0.470 s 35.72 28.62 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 w 15813-0wc-4 0.093 w 4.48 0.24 0 0 0 0 1(V 12F-0sw 0.066 w 4.94 0.47 0 0 0 0 �C 4A1-2w 0.470 w 35.72 52.43 0 0 0 0 C 16838ad 0.026 - 1.98 1.09 80 80 158 87 F 21A32c 0.020 - 1.52 0.00 0 0 0 0 6 c)AEDexcursion -0 Envelope loss/gain 158 82 12 a) Infiltration 0 0 b) Room venfilalion 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances @ 1200 0 0 Lessendemal bad 0 0 Lesstransfer 0 0 Redistribution 0 0 14 Subtotal 158 82 1151 Duct bads 57% 71% 91 58 Total room load 249 140 Air required(cfm) 8 7 Printout certified by ACCA to meet all wftgl-tt50fC RightSuBe Residentixl6.0.02RSR40615 AC(5h CAW DocumentsWrightsolt HVAOTrent Hams t.rry Calc= MJ8 Orientation = N 2005Feb-28 00:32:45 Pape 7 Level 2 Job #: Job 4 Performed by Blair Singleton for: Trent Harris Rexburg, ID 83440 Scale: 1: 108 Page 1 Right -Suite Residential 6.0.02 RSR40615 2005-Feb28 00:33:22 Documents\Wrightson HVAC\.. Level 1 Job #: Job 4 Performed by Blair Singleton for: Trent Harris Rexburg, ID 83440 Pho ne: 3517857 Scale : 108 Page 2 Right -Suite Residential 6.0.02 RSR40615 2005-Feb-28 00:3322 Documents\Wrightsoft HVAC\,, Duct System Summary Entire House Project Information For: Trent Harris Rexburg, ID 83440 Phone:3517857 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 In H2O 0.27 in H2O 0.53 in H2O 0.3610.17 in H2O 0.089 in/100ft 1467 cfm 598 ft Job: Job4 Date: Feb 16, 2005 By: Blair Singleton Cooling 0.80 in H2O 0.27 in H2O 0.53 in H2O 0.3610.17 in H2O 0.089 in/100ft 1467 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FIR Diam (in) Rect Size (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bea 2 c 31" 191 194 0.090 6 Ox 0 VIFx 59.0 340.0 Kitch Utility Room h 249 9 9 0.115 6 Ox0 VIFx 12.0 300.0 st3 Living Room c 1837 103 113 0.104 6 Ox 0 VIFx 36.0 310.0 st2 Bea 4 h 3616 134 124 0.092 6 OX 0 VIFx 61.0 330.0 Kitch Kitchen/Dining-B c 2818 58 174 0.105 6 OXO VIFx 33.0 310.0 st2 Master Bea It 3694 137 122 0.111 6 Ox 0 VIFx 27.0 295.0 st3 Family Room-B h 3727 138 44 0.114 6 Ox0 VIFx 29.0 285.0 st3 Family Room h 3727 138 44 0.103 6 Ox0 VIFx 40.0 310.0 st2 Master Bath c 2850 175 176 0.115 6 Ox 0 VIFx 36.0 275.0 St3 Kitchen/Dining-A c 2818 58 174 0.101 6 OX 0 VIFx 45.0 310.0 SU Living Rcam,A c 1837 103 113 0,104 6 Ox 0 VIFx 44.0 300.0 St2 Family Room -A h 3727 138 44 0.118 6 OX0 VIFx 38.0 265.0 st3 Kitchen/Dining c 2818 58 174 0.089 7 8x4 ShMt 35.0 370.0 St2 Bed h 4201 156 107 0.093 6 Ox0 VIFx 55.0 330.0 Kitch Bea 5 c 1990 121 123 0.089 6 Ox 0 VIFx 53.0 350.0 Kitch Bath h 1142 42 25 0.118 6 Ox0 VIFx 40.0 265.0 91:2 Bakal r vakres have been matualyoverriaaen ,� wrrghtsoft RghtS nrResiaer0al6.0.02RSR40615 2005FeR2800'32'52 ,CCA C9My Documents\Wnghtsoft WAQTrent Hams 1.mP Calc = MJ8 Onentation = N Page 1 Supply Trunk Detail Tabled Trunk Htg cig Design Veloc Diam Rect Duct Duct Name Type (cfm) (cfm) FIR (fpm) (in) Size (in) Material Trunk st2 PeakAVF 561 817 0.089 817 13 8 x 18 ShtMetl stt st3 PeakAVF 597 395 0.111 768 11 8 x 14 ShtMetl stt st1 PeakAVF 1159 1213 0.089 869 16 0 x 0 RndFbg Kitch PeakAVF 602 548 0.089 774 12 8 x 14 ShtMetl Kitch PeakAVF 602 548 0.089 774 12 8 x 14 ShtMetl Return Branch Detail Table Grill Htg clg TEL Design Veloc Diam RectSize Stud/Joist Dud Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (n) Opening (n) Matl Trunk rb5 0x0 379 480 193.0 0.089 507 12 3-14x3.25 3-10x14 SJSp rb4 rb4 Ox0 219 461 171.0 0.100 487 12 3-14x3.25 3-10x14 SJSp rt1 rb2 Ox 0 712 404 136.0 0.126 583 14 8x 22 ShMt rt1 rb1 Ox0 450 415 79.0 0.217 475 12 3-14x3.25 3-10x14 SJSp rt2 Trunk Htg cig Design Veloc Diam RectDUCt Duct Name Type (cfm) (cfm) FIR (fpm) (in) Size (in) Material Trunk rtt PeakAVF 932 865 0.100 838 14 8 x 20 ShtMetl rt2 PeakAVF 450 415 0.217 810 10 8 x 10 ShtMetl rb4 PeakAVF 379 480 0.089 618 11 8 x 14 ShtMetl wnghtsoft RightSuite Residenba16002RSRS0615 2005-Feb-2800:32:52 AC.0 C'MY Documents\Wrightson HVACUrent Harris i.np Calc = W8 Onentabon = N Page 2 Short FSrm Entire House Job: Job4 Dab:: Feb 16, 2005 By: Blair Singleton For: Trent Harris Rexburg, ID 83440 Phone:3517857 Design• • Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semftight Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -31 HEATING EQUIPMENT Make AmStd Trade Freedom 90 Single Stage Model AUX080C960D* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 80000 Btuh 76000 Btuh 56 °F 1467 cfm 0.031 cfm/Btuh 0.80 in H2O COOLING EQUIPMENT Make AmStd Trade Standard 10 Cond 2A7B0048A1 Coil CCBC48A4AC Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 10 SEER 30800 Btuh 13200 Btuh 44000 Btuh 1467 cfm 0.051 cfm/Btuh 0.80 in H2O 1.00 ROOM NAME Area (ft2) Htg load (Stuh) CIg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Master Bath 238 4710 2850 146 147 Family Room 909 11 182 2159 346 ill Bed 4 156 3616 2002 112 103 Bath 2 114 1142 397 35 20 Bed 5 154 3264 1990 101 102 Master Bed 196 3694 1976 114 102 Bed 3 154 4201 1736 130 89 bath 130 0 0 0 0 Bed 2 156 5143 3144 159 162 Kitchen/Dining 420 4697 8453 145 435 Living Room 316 5574 3674 172 189 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft Righk90d.ResWen•al6.002RSR40615 2005-Fea280032:45 XGCk C:\My Ncumenls\W nghtsoft WAQTrent Hams 1. rrp Calc = MJ8 Onentabon = N Page 1 Entire House Other equip bads Equip. @ 0.94 Latent cooling TOTALS 3023 47472 28520 1467 1467 21673 3992 RSM 30562 0 3023 69145 30562 1467 1467 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. WI"19I'1tSOft RightSuite Resieenbal6.0.02RSR40615 2005-Feb-2800'32.45 iCC;A CWy OWcum ts\WngWoll WAQTreni Hams 1."p Calc=MJ8 Onentabon=N Page Building Analysis Entire House Job: Job4 Date: Feb 16, 2005 By: Blair Singleton For: Trent Harris Rexburg, ID 83440 Phone:3517857 Design C• • • Location: Indoor: Idaho Falls, ID US Indoor temperature (OF) Elevation: 4N1 ft Design TD (OF). Latitude: 44ON Relative humidity (% Outdoor: Heating Cooling Moisture difference (gr/lb) Dry bulb (OF) -6 89 Infiltration: Daily range F) - 34 (H) Method We bulb (°� - 60 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Component Btuh/ftz Btuh % of load Walls 5.3 11826 17.1 Glazing 35.7 7608 11.0 Doors 27.4 1149 1.7 Ceilings 2.0 3339 4.8 Floors 1.5 2026 2.9 Infiltration 2.2 4193 6.1 Ducts 17330 25.1 Piping 0 0.0 Humidification 0 0.0 Ventilation 21673 31.3 Adj ustments -0 Total 69M 100.0 Component Btuh/ft2 Btuh % of load Wags 0.3 640 2.0 Glazing 28.1 5975 18.4 Doors 6.7 280 0.9 Ceilings 1.1 1845 5.7 Floors 0.0 0 0.0 Infiltration 0.2 407 1.3 Ducts 11864 36.5 Ventilation 3992 12.3 gains 7510 20.0 Blowerl Adjustments 0 Total 32513 100.0 Overall U-value = 0.059 Btuh/WF Data entries checked. Heating Cooling 50 50 61.5 31.5 Simplified Semi -tight 0 wnghtsoft RightSuge ResirlentiW6.0.02RSR40615 2005-Feb-2800:32:45 ACCP CA&V DucumentslWrightsoft WAQTrent Harris t.np Cab = MJ8 Onentalion = N Page 1 Component Constructions Dare: Feb16,2005 Entire House By: Blair Singleton For: Trent Harris Rexburg, ID 83440 Phone:3517857 Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 70 75 Elevation: 4741 ft Design TD (OF) 76 14 Latitude: 44ON Relative humidity (o/u 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 61.5 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily range (OF) - 34 (H) Method Simplified Wet bulb (OF) - 6o Construction quality Semftght Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area 0-value Insul R Hg HTM Lass Clg RTM Gain (eq raw[;'F7 q�'F,enn) (ShM.) rain) (arnan retw Walls 15813-Owc-4: Basement - 8" concrete, wood framing, interior finish, n 448 0.059 13.0 5.68 2546 0.11 50 R-13 cavity, no board insulation, 4' a 272 0.059 13.0 5A2 1530 0.11 29 s 240 0.059 13.0 5.78 1386 0.12 29 w 184 0.059 13.0 5.78 1063 0.12 22 all 1144 0.059 13.0 5.70 6525 0.11 131 12F-Osw. Wood stud frame, siding or stucco, no board insulation, n 388 0.065 21.0 4.94 1917 0.47 184 R-21 cavity insulation a 330 0.065 21.0 4.94 1630 0.47 157 s 183 0.065 21.0 4.94 904 0.47 87 w 172 0.065 21.0 4.94 850 0.47 82 all 1073 0.065 21.0 4.94 5301 0.47 509 Partitions (none) Windows 4A1-2ov: Operable, vinyl frame, low-e glass, e=0.20 surface 2, 2 pane Doors 11 KO: Metal door, fiberglass cue, with storm Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation n 32 0.470 0.0 35.7 1143 15.9 508 n 71 0.470 0.0 35.7 2536 15.9 1128 e 32 0.470 0.0 35.7 1143 52.4 1678 e 6 0.470 0.0 35.7 214 52.4 315 s 60 0.470 0.0 35.7 2143 28.6 1717 w 12 0.470 0.0 35.7 429 52.4 629 all 213 0.470 0.0 35.7 7608 28.1 5975 n 21 0.360 0.0 27.4 575 6.66 140 s 21 0.360 0.0 27.4 575 6.66 140 all 42 0.360 0.0 27.4 1149 6.66 280 1690 0.026 38.0 1.98 3339 1.09 1845 Floors 21A-32c: Carpeted basement floor, Noinsulation, V wide 1333 0.020 0.0 1.52 2026 0.00 0 wnghtsoft RightSutte Resldential6.0.02 RSR40615 2005-Feb-28 00 32 45 X0% CAMr DocurrentsWrighMoft WAQTrertt Harris Imp Cale= MJa Orientation = N Page 1 Pro ecTSumma Job: Job4 ^� • 7 Date: Feb 16, 2005 Entire House By: Blair Singleton For: Trent Harris Rexburg, ID 83440 Phone:3517857 Notes: Weather: Idaho Falls, ID, US Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TO 76 OF Heating Summary Structure 30142 Btuh Duds 17330 cfm Central vent (309 cfm) 21673 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 69145 Btuh Infiltration Method Simplified Construction quality Semitight Fireplaces 0 Heatingg Comin Area (W) 3023 3029 Volume (fP) 18852 18852 Air changes/hour 0.19 0.10 Equiv. AVF (cfm) 60 31 Heating Equipment Summary Make AmStd Trade Freedom 90 Single Stage Model AUX080C960D' Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 80000 Btuh 76000 Btuh 56 OF 1467 cfm 0.031 cfm/Btuh 0.80 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 16656 Btuh Duds 11864 Btuh Central vent (309 cfm) 3992 Btuh Blower 0 Btuh Use manufacturers data n Rate/swing mulfiplier 0.94 Equipment sensible load 30562 Btuh Latent Cooling Equipment Load Sizing Structure 2835 Btuh Duds -429 Btuh Central vent (309 cfm) -5549 Btuh Equipment latent bad 0 Btuh Equipment total bad 30562 Btuh Req. total capacity at 0.70 SHR 3.6 ton Cooling Equipment Summary Make AmStd Trade Standard 10 Cond 2A7B0048A1 Coil CCBC48A4AC Efficiency Sensible cooing Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 10 SEER 30800 Btuh 13200 Btuh 44000 Btuh 1467 cfm 0.051 cfm/Btuh 0.80 in H2O 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft RghtSuite Residenba160.02RSR40615 2005-Feb-2800.32:45 ."7�05, C:NMy DocumentsUrightsoft WAD.Trent Harris 1.ap Calc = MJ8 Onentabon = N Page 1 Right" Worksheet Job: Job4 Entire House Date: Feb 16, 2006 By: Blair Singleton 1 Room name Enfile House Master Bath 2 Exposed wall 309.0 0 31.0 ft 3 Coiling height 8.0 R 8.0 it heal/000l 4 Room dimensions 14.0 x 17.0 ft 5 Room area 3023.0 fF 238.0 If Ty Construction U-ralue Or HTM Area (if) Load Area (if) Load number (Bluh/fFvF) (Bluh/ff) or perimeter (to (81uh) or perimeter 09 (Bluh) Heat Ir Cool Gross WP/S Heat Cool Gross WKS Heat Cool 6 W 15813-0wc-4 0.093 n 4.48 0.24 480 448 2546 50 0 0 0 0 �O 4A1-2ov 0.470 n 35.72 16.88 32 0 1143 508 0 0 0 0 12F-0sw 0.065 n 4.94 0.47 480 388 1917 184 112 100 494 47 4A1-2ov 0.470 n 35.72 15.88 71 0 2536 1128 12 0 429 191 iI 11K0 15B13-0wc-4 M360 0.093 n a 27.36 4.48 6.66 0.24 21 304 21 272 675 1530 140 29 0 0 0 0 0 0 0 0 l9/ -G 4A1-2ov 0.470 a 35.72 52.43 32 0 1143 1678 0 0 0 0 W 12F-0sw 0.065 a 4.94 0.47 336 330 1630 157 0 0 0 0 I-C 4A1-2ov 0.470 a 35.72 52.43 6 0 214 315 0 0 0 0 W 15813-Owc4 0.093 s 4.48 0.24 240 240 1386 29 0 0 0 0 ILZ12F-0sw 0.065 s 4.94 0.47 264 183 g04 87 0 0 0 0 4A1-20v 0.470 s 35.72 28.62 60 0 2143 1717 0 0 0 0 71KO 0.360 s 27.36 6.56 21 21 575 140 0 0 0 0 W 1581347wc-4 0.093 w 4.48 0.24 184 184 1063 22 0 0 0 0 12F-Osw 0.065 w 4.94 0.47 184 172 850 82 136 124 613 59 4A1-2m 0.470 w 35.72 52.43 12 0 429 629 12 0 429 629 C 16838ad 0.026 - 1.98 1.09 1690 1690 3339 1845 238 238 470 260 F 21A32c 0.020 - 1.52 0.00 1333 151 2026 0 0 0 0 0 6 c)AED excursion 0 194 Envelope losstgain 25949 8740 2434 1380 12 a) Infiltration 4193 407 557 54 b) Room venbiation 0 0 0 0 13 Intemalgains: Occupants@ 230 17 3910 1 230 Appliances@ 1200 3 3600 0 0 Less e#emal bad 0 0 0 0 Lesstmnsfer 0 0 0 0 Redistribution -0 0 0 0 14 Subtotal 30142 16656 2991 1664 15 Duct bads 1 57% 71% 17330 11864 57% 71% 1720 1185 Total room load I 1 47472 28520 4710 2850 Air required (arm) 1467 1467 146 147 Pdritoutcertified byACCA to meet all requirements of Manual J 8th Ed. wrtghtSoR RightSuite Resitlenfia16.0.02RSR40615 2005-Feb-2600:32:45 Af` CAW CocumentslWrightso8 HVAQTmnt Harris Imp Cale= Wit Orientabon = N Page 1 Righ.-.,, Worksheet Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Roam name Fame Room Bed 4 2 Exposed wall 87.0 it 29.0 8 3 Calling height 8.0 0 heat/Cool 8.0 6 heagcool 4 Room dimensions 1.0 x 909.0 0 13.0 x 12.0 it 5 Room area 909.0 tF 156.0 fF Ty Construction U-value Or HTM Area (fn Load Area (f!'J Load number (Bluh/tli°F) (BluhAft') a perimeter (10 (Btuh) or perimeter (fq (Bluh) Heat Coal Gross WP/S Heat Coal Gross WP/S Heat Cool 6 W 15813.Owc-4 0.093 n 4.48 0.24 392 360 2038 40 0 0 0 0 I-O 4A1-2ov 0.470 n 35.72 15.88 32 0 1143 SOB 0 0 0 0 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 4A1-2ov 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 11K0 0.380 n 27.36 8.86 0 0 0 0 0 0 0 0 yf/ 15B13-0wc-0 0.093 a 4.48 0.24 16 16 92 2 95 80 441 8 t-C 4A1-Zav 0.470 a 35.72 52.43 0 0 0 0 16 0 572 839 W 12F-0sw 0.066 a 4.94 0.47 0 0 0 0 0 0 0 0 I-C 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15B73Omd 0.093 s 4.48 0.24 136 136 786 16 104 104 601 13 �qf 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 It-OG 4A1-2ov 0.470 s 35.72 28.62 0 0 0 0 0 0 0 0 11K0 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 W 15813-Dwc4 0.093 w 4.48 0.24 152 162 878 18 32 32 185 4 1}/ 121l 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 I-G 4A7-2ov 0,470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16838ad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 21A32c 0.020 - 1.52 0.00 909 87 1382 0 156 29 237 0 6 c)AED excursion JO 51 Envelope loss/gain 6319 495 20361 914 12 a) Infittnation 781 76 260 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 3 690 1 230 Appliances 1200 0 0 0 0 Lessendemal bad 0 0 0 0 Lesstrarsfa 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 7100 1261 2296 1169 15 Duct loads 57% 71% 4082 698 57% 71% 1320 833 Total mom bad 11182 2159 3616 2002 Air required (cfm) .6 111 112 103 Printout certified by ACCA to meet all requirements of Manua I J 8th Ed. w"49i-1t50ft Right-Suae Residentiai6.0.g2RSR40615 2005-Feb2800:32:45 '�^�`CAW DocumentslWrightsoB WAOnent Hams Imp, Cab=MJ6 Orientation = N Page Righter Worksheet o,, Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name Bath 2 Bed 5 2 Exposed wall 10.0 0 25.0 0 3 Ceiling height &0 ft hwt/c l 8.0 0 heallmol 4 Room dimersios 1.0 x 114.0 ft 11.0 x 14.0 fl 5 Room area 114.0 fF 154.0 fF Ty Construction U-value Or HTM Area (M Load Area (fF) Load number I (Bluh/WF) (Bluh/fF) or perimeter (fQ (Btuh) or perimeter (fQ (Btuh) Heat Cool Gross WPIS Heat Cool Gross WP/S Heat Ccol 6 W 15613-0Wc4 0.093 n 4.48 0.24 0 0 0 0 88 88 508 11 �6 4A1-2ov 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 KV 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 4A7-2w 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 LLD^ 11 KO 0.380 n 27.38 &66 0 0 0 0 0 0 0 0 W/ 15613-Owc-4 0.093 a 4.48 0.24 80 80 462 10 112 96 534 10 Y-C 4A1-2w 0.470 a 35.72 52.43 0 0 0 0 18 0 572 839 W 12F.Ow 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 �C 01-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15813-1)"4 0.093 s 4.48 024 0 0 0 0 0 0 0 0 YI/ 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 4A7-2w 0.470 s 35.72 25.62 0 0 0 0 0 0 0 0 tl----GD 11 KO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 W 15B13-0wc4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 1p/ 12F.Om 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 �C 4A7-2w 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 1615JBad 0.026 - 1.98 1.09 0 0 0 0 0 0 0 0 F 21A-32c 0.020 - 1.52 0.00 114 10 173 0 154 25 234 0 6 c)AED excursion -16 51 Envelope lossigain 635 -7 1848 910 12 a) Infiltration 90 9 224 22 b) Roomwnblation 0 0 0 0 13 Internal gains: Owupads@ 230 1 230 1 230 Appliances@ 1200 0 0 0 0 Less e�demal had 0 0 0 0 Lesstratsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 725 232 2072 1162 15 Dud bads 1 57% 71%1 417 165 57% 71% 1191 828 Total room bad 1142 397 3264 1990 Air required(cfm) 35 20 101 102 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrnght[sot=t Right -Suite Residentlal6.0.02RSR40615 2005-Feb2800:32:45 ACCA C Wy Docurrents`.WnghtsoR WAOTrenl Hams l.rra Calc= MJ8 Onentation = N Page Righ""Vorksheet Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name Master Bed Bed 2 Exposed wall 18.0 ft 25.0 It 3 Ceiling height 8.0 R heet/cool 8.0 ft heat/cool 4 Room dim ensions 14.0 x 14.0 ft 11.0 x 14.0 ft 5 Room area 196.0 fF 154.0 fF Ty Construction U-value Or HUM Area (ff) Load Area (fF) Load number (Bluh/fP--'F) (Btuh/fn w perimeter (fQ (Btuh) or perimeter (fl) (61uh) Heat C001 Gross WP/s Heat Co01 Grass WP/S Heat Cool 6 W 15813 Owc l 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 4Al-2ov 0.470 o 35.72 15.88 0 0 0 0 0 0 0 0 12F-Osw 0.065 n 4.94 0.47 112 82 405 39 88 68 336 32 4A7-2w 0.470 n 35.72 15.88 30 0 1072 477 20 0 714 318 11 11 KO 0.360 n 27.36 6.66 0 0 0 0 0 0 0 0 15613Avc-4 0.093 a 4.48 0.24 0 0 0 0 0 0 0 0 4A1-2ov 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 12F.Osw 0.065 a 4.94 0.47 16 16 79 8 112 112 553 53 4A1-2ov 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15B13-Dwc-4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 1p/ 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 {L--GD 4A1-2cv 0.470 s 35.72 28.62 0 0 0 0 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 0 0 0 0 W 15013-Owc-4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 12F-Osw 0.065 w 4.94 0.47 16 16 79 8 0 0 0 0 4A1-2ov 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16B-Mad 0.026 - 1.98 1.09 196 196 387 214 154 154 304 168 F 21A-32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -82 -56 Envelope loss/gain 2022 663 1908 515 12 a) Infiltration 323 31 449 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupa nts230 2 460 1 230 Appliances@ 1200 0 0 0 0 Less external load 0 0 0 0 Lesstmnsfer 0 0 0 0 Redistribution 0 0 311 225 14 Subtotal 2345 1154 2667 1014 15 Duct loads 57% 71% 1348 822 57% 71% 1534 722 Total room load 3694 1976 4201 1736 Air required (cfm) 114 102 130 89 Printout certified by ACCA to meet all requirements of Manual J Sth Ed. wr-rghtsoR Right -Suite Resldenbal6.UO2RSR40615 2005-Feb-2800.32'.45 iaY_:CJA, C:1My DocumentslWnghlsoh WAOTrent Hams I. up Calc = MJ8 Onentatron = N Page 4 Right._., Worksheet ti Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name bath Bed 2 2 Exposed well 10.0 ft 29.0 R 3 Ceiling height 8.0 N hmVmo l 8.0 N heat/000l 4 Rcomdimensioas 13.0 x 10.0 R 13.0 x 12.0 it 5 Roomarea 130.0 ff 156.0 ff Ty Construction U-value Or HTM Area (ft') toad Area (t1') Load number I (Btuh/ff-°F) (Bluh/fF) or perimeter (f0 (Bluh) or perimeter (fq (Bluh) Flint Ccol Gross N/P/S Heat Curl Gmss WP/S Heat Curl 6 W 15813-0wc4 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 _ 4A1-2ov 0.470 n 35.72 15.88 0 0 O 0 0 0 0 0 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 4A1-2av 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 11 11K0 0.360 n 27.36 6.66 0 0 0 0 0 0 0 0 lq/ 1581311wc4 0.093 a 4.48 0.24 0 0 0 0 0 0 0 0 T-0 4A1-2m 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 12F-Osw 0.065 a 4.94 0.47 80 74 366 35 96 96 474 46 Y-0 4A1-2m 0.470 a 35.72 52.43 6 0 214 315 0 0 0 0 W 15813-0wc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 14/ 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 104 74 366 35 IL 4A1-2w 0.470 s 35.72 28.62 0 0 0 0 30 0 1072 859 11 KO 0.360 s 27.36 6.65 0 0 0 0 0 0 0 0 W 15B13-Owc4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 19! 12F-Osw 0.066 w 4.94 0.47 0 0 0 0 32 32 158 15 �C 4A1-2av 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16B38ad 0.026 - 1.98 1.09 130 130 257 142 156 156 308 170 F 21A-32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -2 165 Envelope loss/0ain 837 489 2378 1290 12 a) Infillmlion 180 17 521 50 b) Roomvenfiletion 0 0 0 0 13 Interval gains: Occupants@ 230 1 230 1 230 Appliances@ 1200 0 0 0 0 m Less erdeai bad 0 0 0 0 Lesslmnsfer 0 0 0 0 Redistribution -1016 -737 367 266 14 Subtotal 0 0 3265 1836 15 Dud loads 57% 71% 0 0 57% 71% 1878 1308 TobaI room load 0 0 5143 3144 Air required (din) 0 0 159 152 Printout cerfified by ACCA to meet all requirements of Manual J 8th Ed. A&wrI40"tso11fit RightSude Residenfial 6.0.02 RSR40615 2005-Feb-28 00:32:45 CAW WcumentslWrightsod HVACITrent Hams f.mp Cale=MJB Odentabon=N Page Right, Worksheet Job: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Raom creme IOtchen/Dining Living Roam 2 Exposed wall 21.0 0 24.0 0 3 Ceiling height 8.0 R heal] o f 8.0 6 Crest/cool 4 Room dimensions 1.0 x 420.0 it 1.0 x 316.0 it 5 Raom area 420.0 if 316.0 If Ty Construction U- lue Or HTM Area (ff) Load Area QF) Load number (Btuh/fF-'F) (Btuh/ff) or perimeter (t4 (Bluh) or permleler n (Btuh) Heat C.1 Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vy 15513-Owe4 0.093 n 4.48 0.24 0 0 0 0 0 0 0 0 I-�i 40k1-2w 0.470 n 35.72 15.88 0 0 0 0 0 0 0 0 12F.Osw 0.065 n 4.94 0.47 168 138 682 65 0 0 0 0 4A1-20v 0.470 n 35.72 15.88 9 0 321 143 0 0 0 0 11 11K0 0.360 n 27.36 6.66 21 21 575 140 0 0 0 0 �q/ 15813-0wc4 0.093 a 4.48 0.24 0 0 0 0 0 0 0 0 `C 4A7-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 12F4sw 0.065 a 4.94 0.47 0 0 0 0 32 32 158 15 L--G 4A1-2w 0.470 a 35.72 52.43 0 0 0 0 0 0 0 0 W 15B13-Owc4 0.093 s 4.48 0.24 0 0 0 0 0 0 0 0 ILZ12F-Osw 0.055 s 4.94 0.47 0 0 0 0 160 109 538 52 4A7-2w 0.470 s 35.72 28.62 0 0 0 0 30 0 1072 859 11K0 0.360 s 27.36 6.66 0 0 0 0 21 21 575 140 w 15B134)wc4 0.093 w 4.48 0.24 0 0 0 0 0 0 0 0 gyp/L 12F-Oew 0.066 w 4.94 0.47 0 0 0 0 0 0 0 0 C 4A1-2w 0.470 w 35.72 52.43 0 0 0 0 0 0 0 0 C 16B38ad 0.026 - 1.98 1.09 420 420 830 459 316 316 624 345 F 21A32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 6 c)AED emursion 340 131 Envelope loss/gain 2408 467 2967 1542 12 a) Infiltration 377 37 431 42 b) Room wn5latbn 0 0 0 0 13 Internal gains: Occupants@ 230 3 690 2 460 Appliances@ 1200 3 3600 0 0 Less edemal bad 0 0 0 0 Lessireosfer 0 0 0 0 Redisidbution 198 143 141 102 14 Subtotal 2982 4936 3539 2146 15 Dud loads 57% 71% 1715 3516 57% 71% 2035 1528 Total mom load 4697 8453 1 5574 3674 Air required(cfm) 145 435 172 189 Pdrdout certified by ACCA to meet all requirements of Manual J 8th Ed. wr7g1'1C5s0R RightSuile Residential6.0.02RSR40615 2005-Fetr2800:32:45 C:1* Docum Mt WdghUo8 WAQTmntHanis t." Calc= Wa Orientation = N Page Right -Worksheet Jot: Job4 Entire House Date: Feb 16, 2005 By: Blair Singleton 1 Room name Utility Room 2 Exposed wall 0.0 it 3 Ceiling height 8.0 it heel/cool 4 Room dimensions 10.0 x 8.0 it 5 Room area 80.0 fF Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuh/fF--°F) (Btuh/ft') or permeler (fb (Bluh) or perimeter Heat Cool Gross WPIS Heat Cool Gross N/P/S Heat Cool 6 V,J 158134hwc-4 0.093 n 4.48 0.24 0 0 0 0 I-G 4A1-2w 0.470 n 35.72 15.88 0 0 0 0 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 4A1-2w 0.470 n 35.72 15.88 0 0 0 0 11 11K0 0.360 n 27.36 6.66 0 0 0 0 tVi1 15M-Owc-4 0.093 a 4.48 0.24 0 0 0 0 -G 4A1-2w 0.470 a 35.72 52.43 0 0 0 0 W 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 I-G 4A1-2w 0.470 a 35.72 52.43 0 0 0 0 W 15B13-Owc4 0.093 s 4.48 0.24 0 0 0 0 lq! 12F Osw 0.065 s 4.94 0.47 0 0 0 0 �L-- 4A1-2w 0.470 s 35.T2 28.62 0 0 0 0 11 KO 0.360 s 27.36 6.66 0 0 0 0 W 15813Awc4 0.093 w 4.48 0.24 0 0 0 0 U/ 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 I-G 4A1-2w 0.470 w 35.72 52.43 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 80 80 158 87 F 21A-32c 0.020 - 1.52 0.00 0 0 0 0 6 c)AEO excursion .6 Envelope loss/gain 158 82 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances@ 1200 0 0 Less external had 0 0 Lesstmnsfer 0 0 Redistribution 0 0 14 Subtotal 158 82 15 Duct loads 57% 71% 91 58 Total room load 249 140 Air required (cfm) 8 7 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr/ght501Ft Right -Suite Restdenual 6.0.02 RSR40615 2005-Feb-2800: 32.45 .¢GC.� C:\hy Documents`.Wrghlsot HVAQTrent Hams 1.rrp Calc = W8 Onentanon = N Page 7 Level s ® 176 elm ® 174 cfm ® 174 etm ----- _ I:b con Master Bed Bed 3 Master Bath 480 cfm 461 elm Kitchen/Dining Master Closet ® g tm Utility Room ® 174 cfm Pantry bath closets Living Rou:-. ® 13 On Garage Bed 2 F _L2 141 cfm t Job #: Job 4 Scale: 1 : 108 Performed by Blair Singleton for: Page 1 Right -Suite Residential Trent Harris 6.0.02 RSR40615 2005-Feb-26 00:3322 Rexburg, ID 83440 C:\My Documents\Wrightsoft HVAC\... Phone: 3517857 Level 1 Job #: Job 4 Performed by Blair Singleton for: Trent Harris Rexburg, ID 83440 Phone. 3517857 Scale: 1 : 108 Page 2 Right-SuHe Residential 6.0.02 RSR40615 2005-Feb28 00:33:22 DocumentsMrightsoR HVAC\... Duct system Summary Entire House Project Information 11 For: Trent Harris Rexburg, ID 83440 Phone:3517857 Job: Job4 Date: Feb'16, 2005 By: Blair Singleton Hearing Cooling External static pressure 0.80 In H2O 0.80 In H2O Pressure losses 0.27 in H2O 0.27 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply / return available pressure 0.36 / 0.17 in H2O 0.36 / 0.17 in H2O Lowest friction rate 0.089 in/t00ft 0.089 in/100ft Actual air flow 1467 cfm 1467 cfm Total effective length (TEL) 598 it Name Design (Btuh) Htg (cfm) CIg (cfm) Design FR Diam (in) Rect Size (in) Dud Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bea 2 c 3144 191 194 0.090 6 Ox 0 VIFx 59.0 340.0 Kitch Utility Room h 249 9 9 0.115 6 OxO VIFx 12.0 300.0 st3 Living Room c 1837 103 113 0.104 6 Ox 0 VIFx 36.0 310.0 st2 Bed a h 3616 134 124 0.092 6 Ox 0 VIFx 61.0 330.0 Kitch Kitchen/Dining-B C 2818 58 174 0.105 6 OxO VIFx 33.0 310.0 b12 Master Bed h 3694 137 122 0.111 6 OxO VIFx 27.0 295.0 st3 Family Room-B h 3727 138 44 0.114 6 OxO VIFx 29.0 285.0 st3 Family Room h 3727 138 44 0.103 6 Ox 0 VIFx 40.0 310.0 st2 Master Bath C 2850 175 176 0.115 6 Ox0 VIFx 36.0 275.0 st3 KitcheNDining-A C 2818 58 174 0.101 6 OXO VIFx 45.0 310.0 st2 Living Room -A c 1837 103 113 0.104 6 OX 0 VIFx 44.0 300.0 st2 Family Room -A h 3727 138 44 0.118 6 OxO VIFx 38.0 265.0 st3 Kitchen/Dining c 2818 58 174 0,089 7 8x4 ShMt 35.0 370.0 st2 Bed h 4201 156 107 0.093 6 Or VIFx 55.0 330.0 Mtch Bad 5 c 1990 121 123 0.089 6 Ox 0 VIFx 53.0 350.0 Kitch Bath h 1142 42 25 0.118 6 OxO VIFx 40.0 265.0 st2 BDkVkde vall[M iw beenma 1iYoverridden ,� wnghtsoft RightSLee Recitlendal G0.02 RSR00615 2005-Feb-28 00 32 52 ACCA CAMy Documents\Wdghisoft WAQTrent Hams t.rrp Cale= MA Onentabon = N Page i Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam Rect Dud Dud Name Type (cfm) (Cfm) FIR (fpm) (in) Size (in) Material Trunk st2 PeakAVF 561 817 0.089 817 13 8 x 18 ShtMetl st1 st3 PeakAVF 597 395 0.111 768 11 8 x 14 ShtMetl st1 st1 PeakAVF 1159 1213 0.089 869 16 0 x 0 RndFbg Kitch PeakAVF 602 548 0.089 774 12 8 x 14 ShtMetl Kitch PeakAVF 602 548 0.089 774 12 8 x 14 ShtMetl Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam RectSize Stud/Joist Dud Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox0 379 480 193.0 0.089 507 12 3-14x3.25 3-10x14 SJSp rb4 rb4 Ox0 219 461 171.0 0.100 487 12 3-14x3.25 3-10x14 SJSp rt1 rb2 ox0 712 404 136.0 0.126 583 14 8x 22 ShMt rt1 rbt Ox0 450 415 79.0 0.217 475 12 3-14x3.25 3-10x14 SJSp rt2 Trunk Htg Cig Design Veloc Diam Rect Dud Dud Name Type (cfm) (cfm) FIR (fpm) (in) Size (in) Material Trunk rt1 PeakAVF 932 865 0.100 838 14 8 x 20 ShtMetl rt2 PeakAVF 450 415 0.217 810 10 8 x 10 ShtMetl rb4 PeakAVF 379 480 0.089 618 11 8 x 14 ShtMetl ti wnghtSC) t RightSuge Residenbal6.0.02RSR40615 2005-Feb280032,52 A.CA Cab?j Documents WnghtSoft WAO,Trent Hws l.rtp Cate =MJ8 Onentabon=N Page