RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date: Z - 7-3
Building Permit Number:
Project: Job Address: _ 87 gar
Zoning: LP—1 Number of Stories: _L Basement: G No / Fin. Unfin. Fixtures:
Floor Area (sf):
Valuation: $
finished,
Permit Fee: $
unfinished, garage
Plan Check Fee: $
The following comments based on the 2003 edition of the International Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
specifications does not permit the violation of any section ofthe International Residential Code or any federal,
state or local regulations.
PLAN CHECK
A. lans
A.
Scale Legible
Yot Plan Y N lood Plain
/Floor / Foundation Plan
Section showing construction details
All Building Elevations
Design Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
Truss Calculation Sheets & Floor Joist Details
echanical Design
_ZEnergy Calculations (R320 & Ch 11)
B. Zoning kheck one - in some cases LDR2 and MDR may apply)
_LDR / LDRI _Lot area - LDR- 12,000 sq. ft. min. (width 80 ft. min) & LDRI- 8,000 sq. ft. min
(width60 ft. min.).( LDRI duplex - 10,000 sq. ft. min.)
C. Use
Single Family _Duplex (LDRI only - Conditional use permit?)
D. Set Backs (taken from eaves)
ront set back (32 ft. from curb) Note: 60% min of front yard green
L ear set back (LDR 25 ft. & LDR1 20 ft.)
e'- `Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
Zuilding-Height (maximum 30 ft.)
E. Footings
Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing)
_Rebaz (24#4 continuous)
%oting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab - interior)
F. Foundation
foundation walls w/ rebar (city ordinance)
Z2 u e. 3�.
A/2" Anchor Bolts with 3"�"—" * I � ' square washers (incl. interior bearing walls) R403.1.6.1
foundation Drainage (foundations on sift soil shall be designed per R405)
Damp proofing/Waterproofing to finish grade. R406.1(fnd. extends 6" min above grade R404.1.6)
Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
Crawl Space Ventilation/Insulation =1 sf vent per 150 sf. (with moisture barrier 1 sf. per 1500 sq. .)and
within 3' of each corner (insulate walls vent to inside of home) R408.2
Grading slope away from house. R401.3
G. Frame
Seismic Hold Downs and Braced Wall Panels (R602.10)
Floors joists sized as per R502.3, Wood 1-joists sized per manufr.
Joists Under Load Bearing Partitions shall be doubled. R502.4
Girders sized per R502.5 or per manufr. Tables for engineered products
Cantilevers (comply with R502.33 or manufr instruction)
u
`.
2-Floor Sheathing (3/4" min for joists 24" oc & 5/8" for joists 16" oc) R503.1
/ Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3
_Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7
/Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
/Rafter and Truss tie -downs. (R802.10.5)
LAttic Access 22" x 30" min. opening (R807)
H. Exterior Covering
/Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1
I. #oof Covering and Ventilation
Roof Ventilation as per R806
LAsphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.__)
I Firewalls
Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
//Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire -rated door) R309.1
Two Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1
Twin homes & Townhouses (2 hr separation & 4' overburn protection or parapet) R317.2
t-KOne hr walls parallel to and within 3 ft of property line w/ NO openings. R302
Penetrations in previous 3 items to comply with R317.3
K. General Requirements
House Numbers R321
Half Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3
Interior and exterior stair illumination shall comply with R303.6.
Bathroom Fixture clearances comply with Figure R307.2
/ One room at least 120 sf.; Z_�`6ther habitable rooms 70 sf. min w/ a min. dimension of 7 ft. R304
*areas w/ sloped ceilings less than 5 ft in height & furred ceilings less than 7 ft DO NOT comply
*50% or more of the required area must be at least 7ft high in rooms w/sloped ceiling
L
Egress clearance from window wells under cantilevered floors. R310.2
Glazing at Hazardous Locations R308
_ZEmergency Egress in all sleeping rooms and basements with habitable space R310
r/ One required Exit Door shall comply with R311.4
/Landings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3
I/stair Rise / Run (7 3/4" max. rise & 10" min. tread, nosing req'd if <11") /gtair Width (36" min),
_ZStairway Headroom (68" min.) ZHandrails (34"to 38" above stair nosing)(11311.5)
-AJpecial conditions for circular, spiral and winder stairways and bulkhead enclosures R311.5.8
Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2
uardrails complying with R312 !Handrails complying with R311.5.6
-Zsmoke Alarms (each bedroom and common area and one on each level (R 313)
L. Energy
_/Homes with glazing < 15% of gross area of ext. walls (Townhouses < 25%) to comply w/ Chapter 11.
*Otherwise shall meet requirements of IECC for respective building type. N1101.2
Zapor retarder on warm in winter side of walls, ceiling and floors R318
/Water Heater heat traps IECC 504.7
, uct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3
{ Plans match quantities & values on a "passing" REScheck compliance report
M. Mechanical
as appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2
�oom access 24" min width/Attic access clear opening 2000/Under floor r.o. 2200. M1305
pL Potential vent/connector offset > 75% of total height (Exception provided by G2428) G2427.6.4
Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3
_Gas "point of delivery" and material used to determine pipe sizing. G2413
..
2003 IRC Heat Loss / Heat Gain Plan Review and Field
Inspection Checklist2/05
Numbers in parenthesis refer to applicable sections in the 2003 IRC.
Plan Review:
Before accepting a submittal you may wish to be sure of the following:
Yes/No
• Are submitted documents of sufficient clarity? (R106.1.1)
• If software, is it ACCA Manual J, 8b' ED. certified? (M1401.3)
• Are there room by room load calculations shown? (M1401.3)
• Is there a duct design based on ACCA Manual D? (M1601.1)
• Are the appliances specified correctly by ACCA Manual S?
(11106.1.1, M1601.1) ACCA Manual S regulates equipment sizing: +40% Nat Gas,
+15% AC.
Through the plan review process you may wish to verify the following:
• Is the design location correct?
/
• Is the building orientation correct?
• Are the design parameters correct? (Inside htg=70, clg=75)
• Do the R-values specified in the plans match the calculations?
• Do the U-values specified in the plans match the calculations?
• Check the gross areas for walls, Floors, ceilings, doors and glazing.
• Are there any fireplaces correctly specified?
• Are the rooms accurate?
• Is there any window shading?
• Are the ducts located in conditioned space? 7
• If yes, is there a BTU loss for the duct system? (Incorrect.) �`—
• If no, is the proper duct insulation specified?
Field inspections will require a stamped copy of the approved duct design and
equipment selection on site. You may wish to determine compliance with the
following:
• Has the duct design be followed?
• Have appropriate controls to assure design CFM been installed?
• Has all required duct insulation been installed?
• Has the specified equipment been installed?
The information listed above is simply reference material to assist with achieving
code compliance in regard to equipment sizing and duct design only.