Loading...
HomeMy WebLinkAboutRESCHECK - 05-00024 - 310 Oaktrail Dr - New SFR0 D REScheck Compliance Certificate 2000 IECC Kehfivare Version 3.5 Re -lease I e Perrmt Number Checked Bv/DatVz�cl Data filename: C:0acuments and SettrngslAdministratorlMy I)ocumentslRESchecklMeadow Brook ID.rck CITY: Rexburg STATE.- Idaho HDU: 8693 CONSTRUCTION TYPE: dingle Family DATE: 01/27/05 DATE OF PLANS: January 27, 2(l05 PROJECT DEscRU)TIoN: Spec Home „Meadow Brook" Oakbrook Subdivision Lit: 2� 346 Oaktrail Drive Rexburg., JD DESIGNERTONTRACTOR: Kartchner Hames 3456 E_ 17 Street Suite 2 10 Ammon Cit��, ID 83406 PROJECT NOTES: 2x6 Walls. CONTLIANCE: Passes Maximum UA = 614 Your Hoene UA = 501 I8.4% Better Than Code ([JA} Gross Area r Cavity Perimeter .-Value e Ceiling I: Flat Ceiling or Scissor Truss � l.pU 4�.0 Wall 1: Woad Frame, 16" 0. C. 1296 21.0 Window i ; VinVl Frame_Dvuble Pare �5 boar 1: Glass 17 Door I Solid 37 Floor 2: Slab, -On -Grade: Unheated 4$3 Insulation depth: 3.0' Furnace 1: Forced Hat Air, 90 A,FUIE Glazing Cont. or Door - Val a -Factor UA 0.0 32 0+() 66 0.490 42 0,490 g 0,200 7 8,0 '_'034 6 CQMPLIANCE STATEMEN-T- The proposed building design described here is consistent with the building pans, s ecifzcati and other calculations submitted with the permit appiicati4ll. The proposed building has been designed to nieet the 2000 IECC CC requirements in RESchec eirsion 3. the REScheckTnspectiaPi hec "I Builder/Designer lease le (fornlerly MEC`ehecM and to comply wIll, the mandatory requirements listed 7 in Date 711 _-, REScheek Inspection Checklist 2000 IECC UScheckSoftware vers- ion 3.5 Release I e DATE: 01/27/05 Bldg. Dept, � Use � J Ceilings" � ] � I. Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity in � CoYnxnents: f � Above -Grade Wails; [ � � 1. Wall 1: Wood Frame, 16" o. c. R-21.0 cavzty° insu�ati�n Comments.- 1 f windovv8-'s: C i I Y- Windov,- 1: Vinyl Frame:Double Pane, U -factor- 0,490 j For v►rindo«rs without labeled U -factors, describe features: J # Panes Frame Type Thermal Break? [ ] ,Yes No j comnlents- Doors,, � 1 � L Door 1: Glass, U -factor.- 0.490 � Comments: I � 2- Door 2: Solid, U -factor: 0.200 � Comments; f � Floors: 1. Floor 2: Slab-On -Grade :Unheated. 3.0' insulation depth, � R-8.0 continuous insulation Corm-nents: j Slab insulation to extend down ftam the tip of the stab to at least 3,0 Vit. QR dawn to of J least the bottom of the slab then honzontall�.r for a total distance of 3.0 ft. � Exterior Insulation, must have a Brigid, opaque, weather -resistant protective covering that � covers the ex -posed (above -grade) insulation and emends at least 6 xn. below grade. 1 I Heating and Cooling Equipment. I. Furnace I: Forced Hot Air, 90 AFLTE or higher Make and Madel Number J Air Leakage: [ ] � Joints, penetrations, and all other such openings in the building envelope that ars sources of sir � leakage must be sealed_ 3 l Recessed fights must be 1} Type IG rated, or 2) installed inside an appropriate air - tight assembly � with a 0.5" clearance from combustible materials. If non -IC raked, the fixture must be installed with. a � 3" clearance from insulation. j Vapor Retarder [ ) � Required an the warm -in -«inter side of all non -vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment rnust be instailed in accordance with the manufacturer's InStaiiation instructions. E ] � Materials and equipment must be identified so that compliance can be determined. [ ] � Manufacturer manuals for all installed heating and cooling equipment and service water heating � equipment intist be provided. j Insulation R -values, glazing U -factors, and beatinge uipment � efficiencv mist be cleariy marked an j the building plans or specifzcations. t J Duct Insulation: J Ducts in llrlCOIIditiOned spaces must be insulated t4 R-5. � Ducts outsYde the building must be insulated to R-8,0. Duct on t rn All joints, scans, and. connections mist be securer fastened with welds, gaskets., mast* adhesives), mastic -plus -embedded -fabric, or types. Duct tape is not permitted.les Exception: Continuously welded and locking -type longitudinal joints and seams operating at less than 2 in. w_g, (5p0 pad an ducts Ducts shall be supported ekrery.- Ip feet or in accordance with the manufacturer's inst Cooling ducts with e�-terior insulation must be covered with a �7apvr retarder. ructions_ Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. ` em r to re Control Thermostats are required for each separate HVAC system. A manual or automatic means to Partially restrict or shut off the heating and/or canting input to each zone or floor shall be provided. Sermvice Water Heating: mater heaters with vertical pipe risers must have a heat trap on bath the inlet and outlet unless the water heater has an integral heat trip or is part of a circulating system. Insulate circulating fat eater pipes to the levels in Table X. Circulating Hot Water systems, - Insulate reel t o hot '"r t r pipes to the levelsF n Table 1. swit"Ming Pools* .All heated swirnining pools must have an onloff heater suTitch and require a cover unless over 20°fo of the heating energy is from nvn-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Msulation: i l j HVAC piping com-,-e��i lej�els in Table 2. ng fluids above 105 tor gilled fluids below 55 TMust be insulated to the FM0 Viable 1: Min*urn 1"sulatiOH Aickness for +G"ir�culating Hot Water I I - es Ti1ClilatiTl,;..lr_.,.__ -.UuI��E�,i1 1 �u�:n��css int �nCnes by Pine �i�PC heated Vv1ater � , -- ?'emRerature (F) 1.70-180 iso -16o 1oc�-1 �a Non-irlti Runouts Tahle 2: Minimum frrsulat on Thickness. for H.�4C Pipes. Fluid Temp. Pi in_g System Types Range F Heating Systems Low Pressure/Temperature Low Temperature Steam condensate (for feed water) Cooling Systems Chilled Water, Refrigerant, and Brine Circulatin L- .+u Mains and Runouts Ch7er rf 2.0 1.{ Lo 1"Sulation Thicknes fil 111cli ' pe Sizes 211 R n 11 "1 ==A,— 4 -.ess Lt . 201-250 1.0 1. 120-200 0.5L 40-55 0.5 0.5 0.75 Lo Below 40 1.0 1. NOTES TO FIELD (B-Lulding Department Use Only)