REScheck Compliance Certificate
2000 IECC
Kehfivare Version 3.5 Re -lease I e
Perrmt Number
Checked Bv/DatVz�cl
Data filename: C:0acuments and SettrngslAdministratorlMy I)ocumentslRESchecklMeadow Brook ID.rck
CITY: Rexburg
STATE.- Idaho
HDU: 8693
CONSTRUCTION TYPE: dingle Family
DATE: 01/27/05
DATE OF PLANS: January 27, 2(l05
PROJECT DEscRU)TIoN:
Spec Home
„Meadow Brook"
Oakbrook Subdivision
Lit: 2�
346 Oaktrail Drive
Rexburg., JD
DESIGNERTONTRACTOR:
Kartchner Hames
3456 E_ 17 Street
Suite 2 10
Ammon Cit��, ID 83406
PROJECT NOTES:
2x6 Walls.
CONTLIANCE: Passes
Maximum UA = 614
Your Hoene UA = 501
I8.4% Better Than Code ([JA}
Gross
Area r Cavity
Perimeter .-Value
e
Ceiling I: Flat Ceiling or Scissor Truss � l.pU 4�.0
Wall 1: Woad Frame, 16" 0. C. 1296 21.0
Window i ; VinVl Frame_Dvuble Pare �5
boar 1: Glass 17
Door I Solid 37
Floor 2: Slab, -On -Grade: Unheated 4$3
Insulation depth: 3.0'
Furnace 1: Forced Hat Air, 90 A,FUIE
Glazing
Cont. or Door
- Val a -Factor UA
0.0 32
0+() 66
0.490 42
0,490 g
0,200 7
8,0 '_'034 6
CQMPLIANCE STATEMEN-T- The proposed building design described here is consistent with the building pans, s ecifzcati
and other calculations submitted with the permit appiicati4ll. The proposed building has been designed to nieet the 2000 IECC
CC
requirements in RESchec
eirsion 3.
the REScheckTnspectiaPi hec "I
Builder/Designer
lease le (fornlerly MEC`ehecM and to comply wIll, the mandatory requirements listed
7 in
Date 711
_-,
REScheek Inspection Checklist
2000 IECC
UScheckSoftware vers-
ion 3.5 Release I e
DATE: 01/27/05
Bldg.
Dept, �
Use �
J Ceilings"
� ] �
I. Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity in
�
CoYnxnents:
f
� Above -Grade Wails;
[ � � 1. Wall 1: Wood Frame, 16" o. c. R-21.0 cavzty° insu�ati�n
Comments.-
1
f
windovv8-'s:
C i I Y- Windov,- 1: Vinyl Frame:Double Pane, U -factor- 0,490
j
For v►rindo«rs without labeled U -factors, describe features:
J # Panes Frame Type Thermal Break? [ ] ,Yes No
j
comnlents-
Doors,,
� 1 � L Door 1: Glass, U -factor.- 0.490
�
Comments:
I � 2- Door 2: Solid, U -factor: 0.200
� Comments;
f
� Floors:
1. Floor 2: Slab-On -Grade :Unheated. 3.0' insulation depth,
�
R-8.0 continuous insulation
Corm-nents:
j Slab insulation to extend down ftam the tip of the stab to at least 3,0 Vit. QR dawn to of
J least the bottom of the slab then honzontall�.r for a total distance of 3.0 ft.
� Exterior Insulation, must have a Brigid, opaque, weather -resistant protective covering that
�
covers the ex -posed (above -grade) insulation and emends at least 6 xn. below grade.
1
I Heating and Cooling Equipment.
I. Furnace I: Forced Hot Air, 90 AFLTE or higher
Make and Madel Number
J Air Leakage:
[ ] � Joints, penetrations, and all other such openings in the building envelope that ars sources of sir
� leakage must be sealed_
3 l Recessed fights must be 1} Type IG rated, or 2) installed inside an appropriate air - tight assembly
� with a 0.5" clearance from combustible materials. If non -IC raked, the fixture must be installed with. a
� 3" clearance from insulation.
j Vapor Retarder
[ ) � Required an the warm -in -«inter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
Materials and equipment rnust be instailed in accordance with the manufacturer's InStaiiation instructions.
E ] � Materials and equipment must be identified so that compliance can be determined.
[ ] � Manufacturer manuals for all installed heating and cooling equipment and service water heating
�
equipment intist be provided.
j Insulation R -values, glazing U -factors, and beatinge uipment � efficiencv mist be cleariy marked an
j the building plans or specifzcations.
t
J Duct Insulation:
J
Ducts in llrlCOIIditiOned spaces must be insulated t4 R-5.
� Ducts outsYde the building must be insulated to R-8,0.
Duct on t rn
All joints, scans, and. connections mist be securer fastened with welds, gaskets., mast* adhesives), mastic -plus -embedded -fabric, or types. Duct tape is not permitted.les
Exception: Continuously welded and locking -type longitudinal joints and seams
operating at less than 2 in. w_g, (5p0 pad an ducts
Ducts shall be supported ekrery.- Ip feet or in accordance with the manufacturer's inst
Cooling ducts with e�-terior insulation must be covered with a �7apvr retarder. ructions_
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
` em r to re Control
Thermostats are required for each separate HVAC system. A manual or automatic means to
Partially restrict or shut off the heating and/or canting input to each zone or floor shall be provided.
Sermvice Water Heating:
mater heaters with vertical pipe risers must have a heat trap on bath the inlet and outlet unless the
water heater has an integral heat trip or is part of a circulating system.
Insulate circulating fat eater pipes to the levels in Table X.
Circulating Hot Water systems, -
Insulate
reel t o hot '"r t r pipes to the levelsF
n Table 1.
swit"Ming Pools*
.All heated swirnining pools must have an onloff heater suTitch and require a cover unless over 20°fo
of the heating energy is from nvn-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Msulation:
i l j HVAC piping com-,-e��i
lej�els in Table 2. ng fluids above 105 tor gilled fluids below 55 TMust be insulated to the
FM0
Viable 1: Min*urn 1"sulatiOH Aickness for +G"ir�culating Hot Water I I - es
Ti1ClilatiTl,;..lr_.,.__
-.UuI��E�,i1 1 �u�:n��css int �nCnes by Pine �i�PC
heated Vv1ater � , --
?'emRerature (F)
1.70-180
iso -16o
1oc�-1 �a
Non-irlti
Runouts
Tahle 2: Minimum frrsulat on Thickness. for H.�4C Pipes.
Fluid Temp.
Pi in_g System Types Range F
Heating Systems
Low Pressure/Temperature
Low Temperature
Steam condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant,
and Brine
Circulatin
L- .+u
Mains and Runouts
Ch7er rf
2.0
1.{
Lo
1"Sulation Thicknes fil 111cli '
pe Sizes
211 R n 11 "1
==A,— 4 -.ess Lt .
201-250 1.0 1.
120-200 0.5L
40-55 0.5 0.5 0.75 Lo
Below 40 1.0 1.