HomeMy WebLinkAboutRESCHECK - 05-00023 - 354 Mariah Ave - New SFRIRE., Se k �o�n pliance Certificate 2000 IECC e ec Software Version'_3.5 Release.] e Data filename: C:0ocuments and Setting5lAdmznistrator CITY: Rexburg STATE: Idaho HDD- 8693 CONSTRUCTION TYPE: Single Family DATE: 01/27/05 DATE QF PLANS: Januan; 27, 205 .h. PROJECT DESCRIPTION: Spec Home "Buriingtian B" Oakb. rook Subdivision Lot- i 354 M nh Avenue Rexbttrg, DE s rGNExlca NTrR-a cToR: Kartchner Hames 356 E, 17 Street Suite 21 Q Ammon City, ID 83406 PROJECT NOTES - 2x -6 Walls, COMPLIANCE-: Passes Maximum UA — 644 Your Home UA _ 591 8-2% Better Than Code (UA) Ceiling i s Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o. c. Window 1 : Vinyl Frame -Double Pane Door I : Glass Door 2: Solid 0 e157 600Z3 Permit Number Checked BY/Date lMy DocumentslRESchecklBuriington ID_rck Floor I : All -Woad Joist/Truss.0ver Outside Air vv*&V Basement Wali 1; Solid Concrete or MasQnn- Wall heiglit- S.0' Depth below grade: 7. U' Insulation depth: S.()' 0 Gross Glazing Area or Cavity Cont. or Door Perimeter -Value - -Factor UA 1179 40.0 0. 117 1. ' 0.0 145 0,490 71 17 0.490 8 37 0.200 13 40-0 0.0 1 13.0 0+0 63 Window 2: Vinvl Frame. -Double Pane 80li9 +490 FI-oor 2: Slab-Oii-Grade.- Li Insulation depth: 3.0' Furnace i : Forced Hat Air, 90 AFUE ba 436 COMPLIANCE STATEMENT" The proposed building design described here �s consistent with the build"ngdans, s ecifand other calcul�.tions subnutted wi.t1� the permit atYon. Thi proposed building has been designed P p rca�.ans. requirein�nts an RESchec�7L ers � i� � .5 Rete to meet the 2000 IECC arrr�erly MEC.�hecl� and to comply with the mandatory requirements listed �n the REScheck-Inspect'o �e Inst. � BuRder/Designer ?ate REScheck Inspection Checklist 2000 IECC REScheck-Software Version 3.5 Release le DATE: 01127105 Bldg. � Dept. � Use Ceilings% I. Ceiling 1 Flat Ceiling or Scissor Truss R-40.0 cavitv f Corm-neilts'. r Above-GradeWalls: I I. Wall 1: Wood Frame; 16" ., R-21.0 vi r insulation JComnicnts � Basement Wads: � ] i i . Basement Wall 1: Solid Concrete or Niasam-, 8.0' ht17. 0' bg18. Q' insul, � R-13.0 cavity insulation J Conuuents: � Windows: { ] � 1. Window 1: Vinyl Fraine:Dauble Pane, U -factor: 0,490 � For windotivs without. labeled U -factors, describe features: � # Panes Frame Tyrpe Thermal Bre�jk`' [ ]Yes[ ]No � Comments: I 1 i 2. Window 2: Vinyl Frame -.Double Pane, U -factor- 0.49 � For waindows Without labeled U -factors., describe features � #Panes Frame Type Thermal Break`? Yes j ] Na Caznrnents: I j Doors: � J 1. Door 1: Glass, U,factor- 0.490 � Comments: [ l � 2- Door 2: Solid, U -factor: 0.200 j Comments,. - Floors: [ � � 1. Floor I: All -Woad JaistlTruss:(]ver Outside Air, R -4o. 0 cavity insuiatioll j Comments-.` [ ] � 2. Flaor 2: Slab -On -Grade : Unheated, 3. (}' insulation depth, R-8.0 continuous insulation � Comments-. � Slab insulation to e;�teiid dow-n from the top of the slab to at least 3.0 ft. OR down to at least the bottom of the slab then horizontally for a fatal distance of 3.0 £t, j Exterior insulation mist have a rigid, opaque, weather. resistant protective covering that J covers the exposed (above -grade) insulation and extends at least 6 in, below grade. � Beating and Cooling Equipment; [ � J I. Furnace I : Forged Hot Air,, 90 AFLTE or higher � Make and Madel Number f � Air Leakage: ] J Joints, penetrations, and all other such openings in the building envelope that are sources of air j leakage must be sealed. l 1 1 Recessed fights must be 1) Type IC rated, or 2} installed inside an appropriate air -tight assemblN- with a +0.clearance from cambusfible materials. If nan-IC rated, the fix-ture must be installed with a 3" clearance from insulation. � Vapor Retarder: [ j � Required on the harm -in-winter side of all non -vented framed ceilings, walls, and floors. � Materials Identification; [ ] � Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ j � Materials and equipment 1tlust be identified so that compliance can be deternuned. � ] � Manufacturer manuals for all installed heating and cooling equipment and service grater beating f equipment must be proN.-,lded. ] � Insudation R -values, glazing U -factors, and heating equipment efficiency nwst be clearly marked on � the building plus or specifications. � Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. � Ducts outside the building must e insulated to R-8.0. J Duct Construction: j I All joints, seams. and connections must be securelv fastened with welds, gaskets. mastics � (adhesives), inastic-plus-embedded-fabric, or tapes. Duct tape is not perInutted, � Exception.- Continuously welded and docking -type longitudinal joins and seams on ducts � operating at less than 2 in. w.g. (50Q Pa). [ � � Ducts sham be supported every 14 feet or in accordance witli the manufacturer's instructions. [ J f Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] � Air filters are required in the return air Systearn_ � ] � The HVAC system must provide a means for balancing sir and water -stems. j Temperature Centrals. Thermostats are required for each separate HVAC system_ A manual or automatic means to � partially restrict or shut off the heating and/or caoling input to each zone or door shall he provided. f � SeiT-ice Water Heating: [ ] { Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the � water heater has an integral meat trap or is part of a circulating system. [ � � Insudate circulating, hot water pipes to the levels in Table 1. i � Circulating Fiat Water Systems* j ] � insulate circulating hot water pipes to the levels in Table 1. � Swimming Pools: I I AIS heated swimming goals must haw an on/off heater switch and require a cover uffless over 20% f of the heating energy- is from non-depletable sources. Pool pimps require a time clpck. Keating and Cooling Piping Insulation: � ] f HVAC piping conveyring fluids above 1�)5 T or dulled fluids below5 5 °F must be insulated to the I levels in Table 2. Table 1: Minimu�rrr Irrsula�i�n Thickness for Circulating Hot I tater Pipes. Insulation Thickness in Inches bv Aire -q;7'pQ Heated Nater Temperatire { iD 170-180 140-160 100-1310 Non-Circwafiri vp to lit 0.5 0,05 0.5 9 Runouts Up to 1.25" 1.0 0.5 Circulati 1.5" to 2.0" 1.5 Mains and Runouts 1.Q Table a Minim',(' Insulation ThieknessforWVAC Fluid Temp. Insulation - I n l t1 Piping t i1n h -- Siz,, Runouts and Less 1. t " to . , Low Pressure/Temperature Law Temperature Steam Condensate (for feed. water) Cooling Systems Chilled Nater, Refrigerant. and Brine 201.-25.0 1.0 1.5 1. 51 2.0 120-200 1.0 1 5 nftl 1. 1. 1.2,0 -5 0.5 0.5 . 75 1.0 Below 40 1.0 1. 1.5 1. NOTES TO FIELD (Building :department Use Oujy)