Loading...
HomeMy WebLinkAboutCHECKLISTS - 05-00022 - 144 Star View Dr - New SFRAO Ar Date: Project: Job Address: 19 FINAL INSPECTION CHECKLIST L CX r V1 4 e-,CAJ qq S! Building Permit Number: The folfowing comments based on the 2000 edition of the Intemational Residential Code should be resolved before an occupancy* permit is issued., This correction list is not a building'-�'permit.`The approval of plans and specifications does not permit the violation of any sect -ion of the Intematio'nal Residential Code or any federal, state or local regulation. OUTSIDE Sriuse Numbers'(vis'ible from fihe styeet) Grade. (yard is sloped away, from foundation) /_Sidewa:1k.& L.ands5'wide �i cafe S�r�p �W16 of granular borrow (hill IT)) --7 Front Set.bac'k Coverage 60% min green �11Cindows - Cover's and Screenstsnallbe releasablovable J Window Wells' min. 24" cEearout and � above) well Exterior S-te��I ps �i 314 max. rise & min. tread) StairwayHandrails =, 4 or more risers or over 3� �<4,} LS strip .. from, the inside for egress max, spacing of uprights} �- uuarpraus (provide if over 3011 above floor/grade & 4" max sphere .spacing for uprmighfs) �Lanajngs (30 X 3b11 min., (not -re q. at the flop of the stair if a door -does not swing over stairs) �f'lhreshv[ds 1 1f2" max. above floor or landing (7 314" max if dear does not swing over landing) ,' Posh (required to be treated, redwood or cedar if in contact of concrete � Roofing (no apparent leaks, installed properly and roofing as per plans) Zdsonry ([intels as per table 703.7. 1 ) Roof Ventilation has per plans} earth) -INSIDE //Egress Doors (all egress doors must be abbe to open from inside without use of keys or fools) Window Energy Talc's: match actual window r' Safely Glazing provided in all doors, within 24" of door arc and below 60", & in tubi enclosure �Bathroom Ventilation (either operable window or fan that vents directly to outside) Sinks, Bathtubs and Showers (check for caulking, operation and leaks) Stairway Illumination (switch at top and bottom) Stairs (7 3/4"max. riser, 10111 min. tread, nosing 3/4" to 1 1I4" with solid risers) ndrails Cont X34" t0 38" , 1 1I2" to uva[I, and 1 X14" to 2" dia. upright < 411 Ariangular space 6" max Guardrails 36" high and continuous, Req'd 3D" or more above grade or floor{, uprights 4" sphere max � spacing, triangular space 6" sphere max spacing} � Garage (Dry waled and taped, firewall penetrations and electrical boxes,. doorto house 20. min: rated.;.,: ducts penetrating firewall must be 26 gauge min. & not open to garage} 01, // Egress ll�indovu�s clear ��" width and. Z4°' height, �.� sf min: opening with 44" max. sill height} /Detectors vicinity and on each stv lbasement- Smn�Ce (En each sleeping roam,. outside in immediate y ry split levels (w/o doors), only on upper floor --all interconnected without a disconnE)cting, $w.itch) Foam Plastic (meets requirement of R318) Gwater Heater Anchorage as over 4'with flex water conn. shall be anchored or scrapped to building} ,W 1Nater Heater Vint (check air flow with return in finished basement) Clothes dryer Dints (solid metal ducts, no screws in duct & vend directly to outside) ,/`-Duct Supports (meta{ ducts supported 10' rain spacing &,non mefial as per manus. installation instr.) Duct Insulation (duct in nen conditioned areas shall be insulated) wAGas erne SUPports spacing 10'for up to 3I4", 12' for over 1"and 6' for tu bing up to 1 'l12" t+ r- F.RAMIN(;,IMFr..14 r..W r.ICI ICT - - -- _,,. � �..,.■�.ra w� Awa ■:��If \�.�V � Date:p�- Project:in,, Job Address:, Building Permit Number: The following comments based on the 24Q3 edition of the Intemational Residential Core should be resoled before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the Intemational Residential Code or any federal, state or local regulations. Exterior ..ZZC(oncrete Slabs {3 112 " min. thickness & 4"ravel base min.} R506.1 __ -,.,/'Sraced Wall Panels (sheathing) (nal'] or staple - 6" o. c. at edges & 12"o. c_ in field} Table 602.3''� � X`_�Adequate uplift control at floor line (sheathing split on plate or 1 %X36 straps 4' a. c. mudsill to studs) aei5m,c nofaWavwns at garage panels e4' widetAPA narrow panel design if X2'8"}, hold-downs mint be on double stud or 3X with all nail holes filled. R602,10.4 .r4oundaiion waterproofing to finish gradeR406A Crawl space ventilation '! sf per 150sf (w/ vapor barrier 1 st per 1500sf} within 3' of corner R408.1-2 Cripple Walls (over 4'sized as Z sto ender 1411 must �Ysolxdly sheathed one side) R602.9 Mud Soli (bolts in proper [ocation, nuts tightened, 2 x2 x31 C" washers (conditional), pressure treated or redwood, joints blocked or under studs at wall and gaps grouted or shimmed} R403.1 a6ml I R602al 1,11 Frame Floor Shea,thingand n ' 'TYP.T&G_611 11 ailing on edges & �f � in fie(perpendicular to joist } Ziolst Sand Size(asperplans)M� ZBearing mm.} & p{�In�c, min. where joists lap over wall or beam} Notching (depth -1/6 max., lenqth-1/3 depth max., not in middle 1/3, ends- 114 depth max.) TJ1_NO Boring (113 "d" max, >2" of fop or bottom or another hole or notch) TJ1 see char r �antilevers- Blocki�, reinforcement, Span and spacing as per plans. ,/--"Joists Under Load Bearing Partitions (shall be doubled as per Section 502.3.3, if plumbing space needed, the ovists shall be blocked 4'o. c_) 'Girders and Beams (as per plans, nailed or mechanically connected to frame and proper bearing) ./'-Joist Hangers (check Iflcation &nailed pr�perly�� Draft Stop (required for over 1000 sq fit. of unusable space at floor/ceil'ng) Basement Walls (pressure treated or redwood sill plate properly fastened to stab} `Stair Opening has per plan & properly supported with hangers or walls) Stairs(check rise- 7 3f4" max., run 10" min., pari.- 318" max, width -3' min. & headroom- 61-811) s i Wall Layout has per plans) .-'Interior Wall Stuff Spacing (load bearing is same as exter�ar}, �4" �.c. max.) ' Bearing Wall Window and Door Headers Nail(edge/ends) FY tBearing Wail Stud Spacing - Ovalis ca inq roof toad nnl 2x4-1 6" o.c. 12' max 2x4-24 11 o. c. 10' max,- 2x6-1 6" o.c. 18' max, - 2u6-24" o. c. 16' max, one floor 8 roof: - 2x4 16 " o.c. 10'Max., two floors &roo 2x4-12" max 10' (Fig 602.3.2.(1-3)) /Double Top Plate (joints lapped min. 2') or Single Top Plate (bearing w/in 1" & adequately tied at joints by 3" x6" steel plates w/ 6 8d on nails each side) R602.3.2 "I" Stud Notch ing,(bearing 25% max.) Borbi40% max, 5/81F min. to edges (60% if doubled) .' Fire Blockino (roof space line at wall, concealed spaces & at studs over 10 ,��`rFirewalls (between duplexes & garage/home) , firewall penetrations -elegy. boxes- rated, duds — '� 26 gauge & not open to garage, door —20 minute rated rein. detail's {35# snow load and 90 mph winds} See tress details Roof Trusses (spaced and brayed as per manufactures) Rafter and Truss Tie -[owns and hangers Rafters Lateral Support (block at bearing when. exceeding 5 t0 1 rule (2x 12) lr Roof Sheathing-, mailing ("H„ clips wl 7/16"), edges -6" o.c,, field -12" o.c. /"Attic Access (provide 22" x 3D" min. access where clear height } 30") J ,��`rFirewalls (between duplexes & garage/home) , firewall penetrations -elegy. boxes- rated, duds — '� 26 gauge & not open to garage, door —20 minute rated rein. detail's {35# snow load and 90 mph winds} See tress details Roof Trusses (spaced and brayed as per manufactures) Rafter and Truss Tie -[owns and hangers Rafters Lateral Support (block at bearing when. exceeding 5 t0 1 rule (2x 12) lr Roof Sheathing-, mailing ("H„ clips wl 7/16"), edges -6" o.c,, field -12" o.c. /"Attic Access (provide 22" x 3D" min. access where clear height } 30") " Roof Ventilation (standard 1/150 or 1I300 if 50 - 80% is 3' above eaves Mechanical (Rough Plumbin9 Insp. Donee �..� ,�,Manufacturer's installatian instructions are with the appliance CIRC 106al-21MI307al) Equipment gas shutoff valves in same room AFP exception) and within 6' of appliance G, C 409.5} Sediment Traps (if not built into. appliance} of Furnace & W. GC 408A) 1XI, Duct Supports and sealed metal - < 10' spacing & Flexible — < 4' max — {2" sag in 4'} Clothes Dryer Ducts (solid metal ducts, no screws extending into duct & gent directly to outside) Duct insulation (I'nsulation in non -conditioned Space) /Room access 24" min width f Attic access clear opening 20x3O min (Under floor is 22x3O)(IMC 306) Pressure. Regulators (access, vented, tee fitting each side) (IFGC 410) ,,Gas pipes not in ventilating or circulating air duct (IFGC 404,1) -Metallic gas pipe bends are smooth & free from buckling, cracks, or other damage (IFGC 4U5.2) ....-- 'Pressure Test:. e," � psi 30min duration lb pressure drop Gas Pipe Material: CSST Branch Lines: -PGTD __-1 Length ft ft ft ft ft ft T� Sch40 MP To POD ft ft ft ft ft ft Copper.4 �i Main Line ��ft Diamete_ Diameter A liance/ TU's cif known) _ - - - - --------- *a ---- 55 4—M ■_ — * � is T i I iJOE I L �■ I�il � � ■ f ir w ., t ar _ A Zb IF M gk L b% IF I 1 op S No -Ir � � r A IF I Li �g� i•.7'� ■ _ + I IL filli L� ` t C I I,� la+ M a �t7 a IM jr q it Eii mrr-- IL It � I N%t: tip ?L MR R !Piv va R IN ■ Mill ir 39 AM IN ■ 91 _ � 1 ■ F ■ +- � ' ikq � y'1 7111� 14 F CIP MEN OA h dbb Nor- Adl:M IN Pi imp i w IF MMI- MEN P 1h a� J 1 1%a 30 R F Li 1 L'9a iOF I 1 Y Ir I & AlN1� �I Ell ME �I F IN 34 ix 21 L A � r wr xr. ■ .40 .� IN